HANNA pH-ORP-ISE - º C/º F analyzer HI2216
aciditypH:-2.0 to 16.0 pH、-2.00 to 16.00 pH、-2.000 to 16.000 pH;redox ORP: ± 999.9mV, ± 2000 mV
Ionic concentrationISE:0.001 to 19990 ppm;Temperature:-20.0 to 120.0 ° C, -4.0 to 248.0 ° F
HANNA pH-ORP-ISE - º C/º F analyzer HI2216
Laboratory high-precision multi parameter analysis and measurement instrument, largeLCDdisplay,
aciditypH-Oxidation-reductionmV-Ion concentration ISE-Rapid and accurate measurement of important water quality indicators such as temperature,
New appearance design, on-screen calibration operation steps prompts, excellent cost-effectiveness,
GLP management function, quickly query current and historical data,
HANNA pH-ORP-ISE - º C/º F analyzer HI2216 ion concentration increment measurement method,Automatic recognition calibration and user-defined calibration,
USBData interface, large capacity data storage, excellent data management.
TECHNICAL INDEX |
HANNA pH-ORP-ISE - º C/º F analyzer HI2216 |
|
Acidity [pH] |
measuring range |
–2.0 to 16.0 pH、 –2.00 to 16.00 pH、 –2.000 to 16.000 pH |
Resolution accuracy |
Resolution:0.1 pH、0.01 pH、0.001 pH;Accuracy:± 0.1 pH, ± 0.01 pH, ± 0.002 pH | |
Calibration Mode |
Up to five automatic recognition calibrations and two user-defined calibrations Built in standard calibration points:1.68、4.01、6.86、7.01、9.18、10.01、12.45pH |
|
temperature compensation |
Automatic or manual temperature compensation-20.0 to 120.0 ° C, -4.0 to 248.0 ° F | |
Oxidation Reduction Process (ORP) |
measuring range |
± 999.9 mV, ± 2000 mV |
resolution |
0.1 mV (± 999.9 mV), 1 mV (± 2000 mV) |
|
|
accuracy@ 20ºC/68ºF |
±0.2 mV (±999.9 mV); ±1 mV (±2000 mV) |
Ionic concentration [ISE] |
measuring range |
0.001 to 19990 ppm (mg/L) |
resolution |
0.001ppm(≤1.999ppm)、0.01ppm(≤19.99ppm)、0.1ppm(≤199.9ppm) |
|
Accuracy @ 20 º C/68 º F |
reading±0.5%F.S. |
|
Calibration Mode |
Automatic recognition calibration, built-in5A calibration point:0.1、1、10、100、1000 ppm |
|
temperature | measuring range |
-20.0 to 120 ° C, -4.0 to 248.0 ° F |
Other indicators |
resolution: 0.1 ° C, 0.1 ° F;accuracy± 0.2 ° C, ± 0.4 ° FIgnore probe error |
|
other | electrode probe |
BNCInterface types: acidity pH electrode, redox ORP electrode, and ISE ion selective electrode [standard HI1131B electrode] |
Input impedance |
1012ohm |
|
Data Storage |
Manual storage: 200 sets of measurement data; Automatic storage: 500 sets of measurement data, interval storage: 600 data
Storage interval: 5, 10, 30 seconds; 1. 2, 5, 10, 15, 30, 60, 120, 180 minutes |
|
Power Mode |
AC230V/12VDCThe power adapter(HI710006) |
|
application environment |
0 to 50 °C(32 to 122°F;273.1 to 323.1K ); RH-max95%(No condensation) |
|
Dimension |