(State Grid) Three phase four wire (three wire) intelligent simulation electric energy meter
The simulated electric energy meter system can simulate various user functions by configuring the simulated electric energy meter. The system can conf
Product details

Product Introduction

The simulated electric energy meter system can simulate various user functions by configuring the simulated electric energy meter. The system can configure the simulated electric energy meter to set and modify parameters such as positive and negative active and reactive power data, peak and valley data, current and voltage power data, etc. It can also simulate event data of the electric energy meter, communication, and wiring measurement faults. It can achieve typical faults such as non freezing of the electric energy meter, incorrect date of the electric energy meter, voltage loss, current loss, wrong phase sequence, incorrect time period and rate, sudden changes in electric energy meter data, and non tripping of the electric energy meter.

Product features/main functions

Communication failure of electric energy meter: unable to perform 485 communication, abnormal carrier module of electric energy meter, inability to read infrared meter of electric energy meter

● Abnormal prompts for energy meter events: voltage loss fault, phase failure fault, current loss fault, reverse phase sequence fault. When the software sets a certain phase event type abnormal fault, the corresponding character flashes, and the time of the event occurrence can be queried.

Internal fault simulation of electric energy meter: sudden change of electric energy fault, time display fault, data display fault, crash fault, data reading fault, clock fault, opening and closing fault, main power supply battery undervoltage, clock battery undervoltage, pulse light fault

Hardware faults of the electric energy meter: the electric energy meter does not start, the electric energy meter crashes, the electric energy meter has a white screen, the electric energy meter has a black screen, the electric energy meter has a flower screen, there is no voltage in phases A, B, and C of the electric energy meter, there is no current in phases A, B, and C of the electric energy meter, and the current in phases A, B, and C of the electric energy meter is abnormal

● Support data writing, enabling the setting and modification of parameters such as positive and negative active and reactive power data, peak and valley data, current and voltage power data, etc. of the electric energy meter, quickly forming data for collection and measurement, line loss load training.

Main technical parameters

Nominal voltage Unom (V)

3×220/380,3×100,3×57.7/100

Nominal current and range (A)

3×1.5(6),3×5(60)

ambient temperature

-40 ℃~+70 ℃, relative humidity: 10%~100%;

System clock error

≤ ±1s/d;

Power failure protection

The data outage storage period is 10 years;

Cross sampling accuracy

Voltage and current: Level 0.5; Merit: Level 1.0; Reactive power: Level 2.0;

Interface segregation

RS485 is an independent optoelectronic isolation interface with an isolation voltage greater than 2000V;

Product standards

DL/T645-2007
DL/T698.45-2017