250 degree elevated low-temperature aging test chamber

250 degree elevated low-temperature aging test chamber

Parameters:

  • -40℃-100℃
  • Temperature fluctuation: ± 0.5 ℃
  • Temperature uniformity: ≤ ±2℃
  • Heating time:3-5℃/min
  • Cooling time:1-1.5℃/min
  • Humidity range: 30% to 98% RH
  • Humidity fluctuation:±3-5%RH
  • Total power: 5.7KW

characteristic:

  • Temperature and humidity control instruments are used“PZ”Large screen display(LCD monitor), simple screen operation, easy program editing, no need for button input,operating buttonDirect TouchjogOptions. The controller operation interface is available in both Chinese and English for selection.(Shanghai Quality Control)
  • have99Group program24Section 99Capacity of cyclic steps, set at each time intervalThe value is 99 hours and 59 minutes.
  • After inputting the data and experimental conditions, the controller has a screen lock function to avoid manual touch and shutdown.
  • haveupgradableRS-232 or RS-485 communication interface, which can be programmed on a computer to monitor the testing process and perform functions such as automatic power on/off(Another selection).
  • Equipped with automatic calculation function, it can immediately correct the temperature and humidity change conditions, making temperature and humidity control more efficientstability
  • The refrigeration unit adopts the original French "Taikang" fully enclosed compressor.
  • The refrigeration system adopts a unit or binary low-temperature circuit system design.
  • Adopting a multi wing air supply fan for strong air circulation, avoiding any dead corners, can make the temperature and humidity distribution in the testing area uniform.
  • The design of air circulation for air outlet and return ensures that the wind pressure and speed meet the testing standards, and can quickly stabilize the temperature and humidity at the moment of opening the door.
  • The independent heating, cooling, and humidification system can improve efficiency, reduce testing costs, extend lifespan, and lower failure rates.