4K closed-loop liquid nitrogen laboratory low-temperature thermostat
The 4K closed-loop low-temperature thermostat provided by Jinzhengmao Technology Co., Ltd. is a variable temperature low-temperature platform based on
Product details

4K closed-loop low-temperature thermostat

Jin Zhengmao4K closed-loop low-temperature thermostatCCSClosed Cycle System)The refrigeration machine has been utilizedG-MThe thermodynamic cycle principle compresses and expands helium gas. The compressor provides the high-pressure helium gas required during the cycle, which is transmitted to the cold head through a flexible metal helium gas pipeline. The compressed helium gas expands and cools inside the cold head, and the expanded low-pressure helium gas returns to the compressor for repeated cycles. The refrigeration unit includes two stages of cooling stages,The first stage cold stage is used to cool the anti thermal radiation screen around the sample, and the second stage cold stage is used to cool the sample.

Jin Zhengmao4K closed-loop low-temperature thermostat 4K provided by Jinzhengmao Technology Co., LtdClosed cycle low-temperature thermostats are produced by domestic and foreign companiesG-MA variable temperature and low temperature platform based on a refrigeration machine, used in conjunction with a temperature controller, can control the temperature of the sample throughout the entire working range. It is easy to operate and has low maintenance costs.

Scope of use:Mainly used for magnetic measurement, optical measurement, photoelectric reaction, light reflection, fluorescence, and magnetic resistance experiments in low temperature and vacuum environments.

advantage:

Compact structure, high cost-effectiveness, low temperature without refrigerant consumption, long maintenance cycle, strong scalability, and easy use;

The sample is in a high vacuum environment or atmosphere;

Integrated optical windows with multiple optional window materials

Multiple gold-plated oxygen free copper sample holders can meet the measurement needs of different experimental requirementsQuick replacement of sample holder

Suitable for electrical, optical, and magnetic measurements in low-temperature environments

Silicon diode thermometer orCernoxthermometer(Used in strong magnetic fields)Installed on the cold finger

The compressor can choose between air cooling and water coolingLong maintenance cycle;

Multiple options can meet the measurement needs of different experiments.

in common use4KRefrigerator specifications and parameters(SHI

in common use4KTechnical specifications and parameters of refrigeration head and compressor(SHI

project

GMrefrigeration machine

Pulse tube cooler

Cold head model

RDK-101D

RDK-101DL

RDK-305D

RDK-205D

RDK-408D2

RDK-415D

RP-062B

RP-082B

RP-182B2S

Low temperatureas low as(Bare machine)

<3K

<3K

<3.5K

<3.5K

<3.5K

<3.5K

<3.0K

<3.0K

<2.8K

Cooling time

150min to 4K

150min to 4K

120min to 4K

90min to 4K

60min to 4K

60min to 4K

100min to 4K

80min to 4K

60min to 4K

Refrigeration capacity

0.1W@4.2K & 3W@50K

0.1W@4.2K & 3W@50K

0.4W@4.2K & 15W@40K

0.5W@4.2K & 3W@50K

1.0W@4.2K & 40W@43K

1.5W@4.2K & 35W@50K

0.5W@4.2K & 30W@65K

1W@4.2K & 40W@45K

1.5W@4.2K & 36W@48K

Cold head weight

7.2Kg

7.2Kg

16Kg

14Kg

18Kg

18.5Kg

23.2Kg

26Kg

28 Kg

compressor

CAN-11B/C

FA40H

CKW-21A

F50H

F50H

F50H

F70H

F-100

power consumption

1.2-1.3KW

1Phase

2.7-3.3KW 3Phase

6.5-7.2KW

3Phase

6.5-7.2KW

3Phase

6.5-7.2KW

3Phase

6.6-6.9KW

3Phase

11.8-13.7KW

3Phase

Cooling water inlet flow rate and temperature

7L/min4-28℃)

7L/min4-28℃)

7L/min4-28℃)

7L/min4-28℃)

6-9L/min4-28℃)

size

461*400*450mm

461*400*450

591*450*588

591*450*588

591*450*588

532*493*443

Compressor weight

70Kg

70Kg

120Kg

120Kg

120Kg

100Kg

Maintenance Cycle

20 000h

20 000h

30 000h

30 000h

30 000h

30 000h

30 000h

Integrated specifications and parameters

in common use4KTechnical specifications and parameters of refrigeration head and compressorSHI

model

project

RDK-101D

RDK-101DL

RDK-305D

RDK-205D

RDK-408D2

RDK-415D

RP-062B

RP-082B

RP-182B2S

temperature range

4K-325K

Required vacuum degree

1Pa

Experimental type

electricity

optics

electricity

optics

electricity

optics

electricity

optics

electricity

optics

electricity

optics

electricity

optics

electricity

optics

Sample holder size

15*25mm

15*25mmCenter openingΦ10mmclear aperture

20*30mm

20*30mmCenter openingΦ10mmclear aperture

15*25mm

15*25mmCenter openingΦ10mmclear aperture

30*40mm

30*40mmCenter openingΦ20mmclear aperture

30*40mm

30*40mmCenter openingΦ20mmclear aperture

30*40mm

30*40mmCenter openingΦ20mmclear aperture

30*40mm

30*40mmCenter openingΦ20mmclear aperture

30*40mm

30*40mmCenter openingΦ20mmclear aperture

Vacuum hood size

Φ31.8mm

40*40mm

Φ41.8mm

50*50mm

Φ31.8mm

40*40mm

Φ45mm

50*50mm

Φ31.8mm

40*40mm

Φ31.8mm

40*40mm

Φ31.8

mm

40*40mm

Φ31.8mm

40*40mm

Sample holder terminal

8individual

not have

8individual

not have

8individual

not have

8individual

not have

8individual

not have

8individual

not have

8individual

not have

8individual

not have

temperature sensor/heater

The standard configuration for temperature sensors is a silicon diode,When in a strong magnetic field, chooseCernoxTemperature sensor. The standard configuration of the heater is50W, can be upgraded to75W

OPTICAL WINDOW

not have

1-5individual

not have

1-5individual

not have

1-5individual

not have

1-5individual

not have

1-5individual

not have

1-5individual

not have

1-5individual

not have

1-5individual

Note:Optical sample holders can have light holes in the middle, and the size can be specified by the user.

in common use4KRefrigerator specifications and parameters(GC)Integrated specifications and parameters

in common use4KTechnical specifications and parameters of refrigeration head and compressorGC

project

GMrefrigeration machine

Cold head model

KDE418SA

KDE415SA

KDE412SA

KDE410SA

KDE401SA

Low temperatureas low as(Bare machine)

<3.5K

<2.5K

Cooling time

60min to4.2K

120min to4.2K

Refrigeration capacity

1.75W@4.2K

35W@50K

1.5W@4.2K

35W@50K

1.2W@4.2K

40W@45K

0.8W@4.2K

35W@50K

1.0W@4.2K

40W@45K

0.25W@4.2K

3W@45K

compressor

KDC6000V

KDC4000F

KDC6000V

KDC2000F

KDC2000VL

power consumption

6.5KW

3.5KW

3.5KW

Cooling method

water-cooling

forced air cooling

water-cooling

forced air cooling

water-cooling

Cooling water inlet flow rate and temperature

7-10L/min28℃)

1800Nm3/h

7L/min4-28℃)

1800Nm3/h

4L/min4-28℃)

Cold head weight

18.9Kg

18.5Kg

18.5Kg

8.9Kg

Compressor weight

118Kg

130Kg

118Kg

86Kg

106Kg

Cold head maintenance cycle

18Month

Compressor maintenance cycle

36Month

in common use4KRefrigeration head and compressor technologyintegrationSpecifications and parametersGC

model

project

KDE418SA

KDE415SA

KDE412SA

KDE410SA

KDE401SA

temperature range

4K-325K

Required vacuum degree

1Pa

Experimental type

electricity

optics

electricity

optics

electricity

optics

electricity

optics

electricity

optics

Sample holder size

30*40mm

30*40mmCenter openingΦ20mmclear aperture

30*40mm

30*40mmCenter openingΦ20mmclear aperture

25*30mm

25*30mmCenter openingΦ15

mmclear aperture

20*30mm

20*30mmCenter openingΦ10mmclear aperture

15*25mm

15*25mmCenter openingΦ10mmclear aperture

Vacuum hood size

Φ41.8mm

50*50mm

Φ41.8mm

50*50mm

Φ31.8mm

40*40mm

Φ41.8mm

50*50mm

Φ31.8mm

40*40mm

Sample holder terminal

8individual

not have

8individual

not have

8individual

not have

8individual

not have

8individual

temperature sensor/heater

The standard configuration for temperature sensors is a silicon diode,When in a strong magnetic field, chooseCernoxTemperature sensor. The standard configuration of the heater is50W, can be upgraded to75W

OPTICAL WINDOW

not have

1-5individual

not have

1-5individual

not have

1-5individual

not have

1-5individual

not have

1-5individual

Note:Optical sample holders can have light holes in the middle, and the size can be specified by the user.

Sample holder options

model

Specifications and Parameters

describe

notes

T8015

15*25mm

Additional electrical sample holder, with upper and lower components8Root terminal post

1All standard equipment10KThe thermostat is equipped with a sample holder by default, and the size can be made according to the standard or designed according to the specific requirements of the user. If the design is complex, fees can be charged at the discretion of the user;

2Standard optical sample holder, comes with a sample press. There are holes on the tablet, and the diameter is the same as the size of the through-hole;

310KThe cooling power of the refrigeration machine varies slightly, and the size of the sample holder can be adjusted within a certain range according to the specific power;

T8020

20*30mm

Additional electrical sample holder, with upper and lower components8Root terminal post

T8030

30*35mm

Additional electrical sample holders on both sides8Root terminal post

T8040

40*45mm

Additional electrical sample holders on both sides8Root terminal post

T8115

15*25mm

Additional optical sample holder, with a middleΦ8The through-hole

T8120

20*30mm

Additional optical sample holder, with a middleΦ10The through-hole

T8130

30*35mm

Additional optical sample holder, with a middleΦ15The through-hole

T8140

40*45mm

Additional optical sample holder, with a middleΦ20The through-hole

T8205

Φ5mm

Powdered sample container, with one side of the container5mmwindow

T8210

Φ10mm

Powdered sample container, with one side of the container5mmwindow

Optical window options

Window panel model

Window panel specifications

describe

notes

W-20

Φ20*1.5mm

Extra quartz window

1The specifications of the windows are all based on the visible area, but the actual size is larger than the visible area;

2Window installation can be selectedORing compression or low-temperature epoxy resin bonding. If the vacuum hood size is small, try to use adhesive as much as possible

W-40

Φ40*2mm

Extra quartz window

K9-W20

Φ20*1.5mm

additionalK9window

K9-W20

Φ40*2mm

additionalK9window

F-W20

Φ20*1.5mm

Additional calcium fluoride window

F-W40

Φ40*2mm

Additional calcium fluoride window


Cable options

name

describe

notes

PTFE wire

Ordinary wire, large heat leakage, diameter0.1-0.3between

The cable does not require the use of a single type of ordinary PTFE wire. It is required to be made according to the requirements, and the wire should be used in conjunction with the corresponding connector

Low temperature coaxial line

Low signal interference and accurate measurement

Phosphor bronze twisted pair cable

Poor thermal conductivity, small heat leakage, diameter0.2mm4Root)

Microwave semi-rigid cable

High frequency cables, used for high-frequency signals

Connector options

Electrical connector model

Specifications and parameters

describe

T91-8POrdinary glass sintering

8pin

Add a quick plug and unplug feature8POrdinary electrical connector

T91-12POrdinary glass sintering

12pin

Add a quick plug and unplug feature12POrdinary electrical connector

T91-SMA

0-18GHz

Equipped with flexible cables

0-12.4GHz

Equipped with semi-rigid and semi flexible cables

T91-BNC

0-4GHz

Equipped with ordinary coaxial line

T91-TRX

Triple coaxial connector

Add a quick plug three coaxial connector

T91-S

Stainless steel junction box

Add a stainless steel junction box

T91-PTEF

PTFE wiring cover

Add a PTFE plate wiring cover on the stainless steel junction box

remarks:

1All thermostats come with two connectors when they leave the factory, one for installing temperature sensors and heaters, and the other for preparing connectors for other performance measurements. When more testing lines are needed, installation holes need to be added or one or more connectors need to be installedBreakout Box.

2In the table above, there areT91-SOption, this option's wiring board and housing form a grounding system as a whole, while the other option isT91-PTEFOption, this option uses PTFE board insulation connection between the shell and the installed joint, and the electrical performance of the shell and joint is independent of each other. Attention should be paid to this issue when selecting





Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!