Jiangsu Shengaohua Environmental Protection Technology Co., Ltd
Home>Products>6B-10C COD national standard reflux digestion instrument air-cooled
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    0519-88866488/88868028/88868159
  • Address
    Zhihui Building, No. 366 Laodong Middle Road, Tianning District, Changzhou City
Contact Now
6B-10C COD national standard reflux digestion instrument air-cooled
6B-10C COD national standard reflux digestion instrument air-cooled
Product details

6BSeries of national standardsCODThe intelligent reflux digestion device is completely in accordance with the regulations released by the Ministry of Environmental Protection of ChinaHJ 8282017(Replace)GB 11914-89)Designed based on basic principles, it can effectively ensure the digestion process of reflux micro boiling constant temperature control heating for 2 hours. The preparation and addition amount of reagent solution are consistent withHJ 8282017Consistent standard requirements can ensure accurate analysis results.

The instrument adopts microcomputer technology for timing control heating method, and can simultaneously heat the all glass reflux device of 250ml conical (straight large grinding mouth) bottles with 6/10/12 grinding ports; To achieve the goals of energy conservation, reducing power load, and improving efficiency.

The instrument uses glass burr reflux tubes instead of spherical reflux tubes, and replaces tap water cooling with air and water cooling technologies, which can save water, reduce storage space, standardize the instrument, and improve the reliability of instrument use; The heating bottom plate adopts a fashionable microcrystalline optical panel design concept, which not only improves the accuracy of sample digestion, but also enhances the beauty of the product.

The chemical solution preparation, operation, and COD calculation of the instrument fully comply with the national standardHJ 8282017Note: For COD water samples with a concentration of ≤ 50mg/L, the sampling volume can be appropriately increased when the sample concentration is low; For COD water samples with a concentration greater than 50mg/L, the accuracy can be improved by diluting the titrant and oxidant; For COD water samples with a concentration greater than 700mg/L, dilution of the water sample concentration is required to complete the result determination; For water samples with high chloride ion content, reference can be madeHJ 828Appendix A of 2017Method judgment and determination.

[Functional Features]

Dual fan convection cooling, independently controllable, with significant cooling effect
Large screen LCD Chinese display, adjustable time and power, users can modify, set, and save on their own
Adopting microcrystalline heating panel and infrared heating method, the heating speed is fast and uniform, and the service life is longer
After digestion is completed, the instrument automatically sounds a warning and stops heating work
Water saving, energy-saving, low thermal radiation, and small space occupation
Easy to operate, can effectively reduce costs and improve work efficiency

Technical indicators

Measurement range: 4-700mg/L, 700-1000mg/L (requires diluted water sample)

Measurement time:≤ 150 minutes (can be set according to user needs)

Measurement error: Potassium hydrogen phthalate standard solution (500mg/L), relative standard deviation not exceeding 5.0%, industrial organic wastewater (500mg/L), relative standard deviation not exceeding 8.0%

Environmental temperature:- 5~40℃

Display mode: LCD display

Dissolved samples: 10 per batch

Dissolving time:Users can set their own time according to their needs, ranging from 1-999 minutes

Fan settings: automatic/manual

Heating power: 1200W (AC 220V ± 22V, 50HZ)



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!