AA3510 flame atomic absorption spectrometer standard typeProduct engineer and application engineer with decades of experience in atomic absorptionproduction,The personnel are from the original Agilent atomic absorption design team. The main products of the company at present are:Atomic absorption spectrophotometerAA-3510Series products. include3510FFlames3510Flame rapid multi-element analyzer, etc., currently available3510The model is from the original Agilent4510It is based on optimizing and upgrading some performance.

AA3510 flame atomic absorption spectrometer standard typemain features

All functions are provided byPCControl operation,Flexible selection of flame and graphite furnace. Unique optical mechanical design,Safe and convenient flame system,Advanced temperature control technology for graphite furnaces,Optional deduction background technology,And various convenient functions provided by the workstation,Adapt to your pursuit of precise automated measurement results.

AA3510In the original AgilentAA4510On the basis of this, the following improvements have been made:
. Using highly sensitive flame sensors to eliminate interference from external light
. Realize safer control over abnormal situations, such as insufficient pressure, air leakage, engine shutdown, etc
. The simple lifting platform structure makes it easier for users to adjust
. Added working software for the hydride generator method
. provide4Gap slit0.1, 0.2 , 0. 4, one
.
Can be installed simultaneously4A hollow cathode lamp
. The software has added a method storage function, allowing users to retrieve standard curves at any time after storage, which can save analysis time

Technical indicators

host

Wavelength Range 190900nm

4/6Lamp lighthouse No need to replace the lamp during multi-element analysis

Wavelength repeatability ±0.1nm

Wavelength accuracy Full band ±0.2nm

Range of absorbance 02.5ABS

resolving power Spectral bandwidth0.2nmCan separate manganese double lines at different times(279.5and279.8)And valley peak energy ratio<30%

Spectral bandwidth(4File)0.1nm,0.2nm,0.4nm,1.0nm

Static baseline drift 0.002ABS/30min(Cu)

weight80kg

size500*450*430(mm)

Grating number 1800strip/mm

D2Background deduction method Background signal1ABSWhen deducting background ability ≥50times

Self absorption background deduction method Power Supply220V AC

Flame system

Air acetylene flame combustion head100mm

Laughing gas - acetylene flame combustion head50mm(Optional laughing gas function)

Dynamic baseline drift of ignition 0.004ABS/30min(Cu)

Precision relative standard deviation 0.5%(Cu,absorbance>0.8ABS)

detection limitCu0.008ug/ml

safety system Automatically cut off gas in case of insufficient pressure, power interruption, abnormal flameout, or mismatched combustion head