AEROQUAL Series 300 Portable Gas Detector
Purpose: AEROQUAL Series 300 intelligent portable gas detector, which can be used in atmospheric environment monitoring, environmental research and ot
Product details

Purpose:

AEROQUAL Series 300 intelligent portable gas detector can be used in fields such as atmospheric environment monitoring and environmental research Superior cost-effectiveness, suitable for both outdoor and indoor use.

AEROQUAL Series 300便携式气体检测仪

Characteristics:

Easy to use, easy to maintain, wide range of applications

The sensor is replaceable

Lithium batteries can be directly replaced on site (can be used for about 8 hours)

Minimum, maximum, and average readings

Zero degree calibration, gain adjustment

Alarm for high or low values

Analog output (0-5V)


Environmental gas sensor:

Gases suitable for field environmental monitoring: anchor carbon monoxide, carbon dioxide, hydrogen sulfide, nitrogen dioxide, non methane hydrocarbons, ozone

Gases suitable for indoor monitoring: carbon monoxide, carbon dioxide, ozone

Gases suitable for monitoring in the field of industrial safety: ammonia, carbon monoxide, carbon dioxide, hydrogen, hydrogen sulfide, methane, ozone, carbon tetrachloride, sulfur dioxide, volatile organic compounds


Technical specifications:

Measurement unit

Ppm or mg/m3 | Temperature: ℃ | Humidity:% RH

Reading function

Instantaneous, minimum, maximum, average

sensor

Removable/replaceable pre calibrated sensors

Display screen status display

Battery level, sensor, backup

calibration

Zero value calibration, gain calibration

output signal

0-5V signal output

power supply

12VDC (power adapter, charging power supply 12VDC, 800mA)

Rechargeable Battery

Lithium battery 12V DC 2700 mA/h

audible alarm

High and low alarms can be set

Housing material

PC and ABS materials, IP20 or NEMA 1 protection level

External dimensions

195x122x54(mm); (with sensor head)

weight

<460g

work environment

Temperature: 5-45 ℃ Humidity: 0-95% RH (without condensation)

Product Certification

Part15 of FCC Rules

EN50082-1:1997

EN50081-1:1992

Measurement range of temperature and humidity sensor

Temperature: -40-124 ℃ Humidity: 0-100% RH (without condensation)

The sensor types and parameters are as follows:

gas

Sensor code

Sensor type 1

Range (ppm)

Minimum detection limit (ppm)

Factory calibration accuracy 2

Resolution (ppm)

Response time (s) 3

Operating condition 4

temperature

humidity

Ammonia (NH3)

NH/NH2

GSS

0-1000

2

<±5 ppm +15%

1

30

0~40℃

10~90%

Ammonia (NH3)

ENG/ENG2

GSE

0-100

0.2

<±0.5ppm + 10%

0.1

120

0~40℃

15~ 90%

Carbon monoxide (CO)

ECM / ECM2

GSE

0-25

0.05

<±0.5 ppm 0-5 ppm

<±10% 5-25ppm

0.01

60

0~40℃

15~90%

Carbon monoxide (CO)

ECN / ECN2

GSE

0-100

0.2

<±1 ppm 0-10 ppm

<±10% 10-100ppm

0.1

30

0~40℃

15~90%

Carbon monoxide (CO)

SH CO / SH CO2

GSE

0-1000

1

<±2ppm + 15%

1

30

0~40℃

10~95%

Carbon dioxide (CO2)

CD

NDIR

0-2000

10

<±10ppm + 5%

1

120

0~40℃

10~95%

Carbon dioxide (CO2)

CE

NDIR

0-5000

20

<±20ppm + 5%

1

120

0~40℃

10~95%

CO2,CO

MS1

NDIR

GSE

0-2000

0-100

10

0.2

See CD and ECN data

1

0.1

120

0~ 40℃

15~90%

CO2,CO,PID

MS2

NDIR GSE

PID

0-2000

0-1000

0-20

10

0.2

0.01

See CD, ECN and PDL data

1

0.1

0.01

120

0 ~ 40℃

15~90%

Chlorine gas (Cl2)

ECL/ECL2

GSE

0-10

0.01

<±0.02ppm + 10%

0.01

30

0~40℃

15~90%

Formaldehyde (CH2O)

EF / EF2

GSE

0-10

0.01

<±0.05 ppm 0-0.5 ppm

<±10% 0.5-10ppm

0.01

120

0~40℃

15~90%

Hydrogen (H2)

HA / HA2

GSS

0-5000

5

<±10ppm + 10%

1

30

0~40℃

10~90%

Methane (CH4)

MT / MT2

GSS

0-10000

10

<±20ppm + 15%

1

60

0~40℃

10~90%

Hydrogen sulfide (H2S)

EHS / EHS2

GSE

0-10

0.04

<±0.05 ppm 0-0.5 ppm

<±10% 0.5-10ppm

0.01

30

0~40℃

15~90%

Hydrogen sulfide (H2S)

EHT / EHT2

GSE

0-100

0.4

<±0.5 ppm 0-5 ppm

<±10% 5-100ppm

0.1

30

0~40℃

15~90%

Nitrogen dioxide (NO2)

ENW

GSE

0-1

0.005

<±0.02 ppm 0-0.2 ppm

<±10% 0.2-1 ppm

0.001

30

0 ~ 40℃

15 ~90%

NMHC

VN

GSS

0-25

0.1

<±0.1 ppm + 10%

0.1

60

0 ~ 40℃

10 ~ 90%

Ozone (O3)

OZS

GSS

0-0.05

0.001

<±0.002 ppm

0.001

240

0 ~ 40℃

10 ~90%

Ozone (O3)

OZU

GSS

0-0.15

0.001

<±0.005 ppm

0.001

60

0 ~ 40℃

10 ~90%

Ozone (O3)

OZL

GSS

0-0.5

0.001

<±0.008 ppm 0-0.1 ppm

<±10% 0.1-0.5 ppm

0.001

60

0 ~ 40℃

10 ~90%

Ozone (O3)

EOZ

GSE

0-10

0.01

<±0.01 ppm + 7.5%

0.01

5

0 ~ 40℃

15 ~90%

Perchloroethylene (C2Cl4)

PE

GSS

0-200

1

<±5 ppm 0-50 ppm

<±10% 50-200 ppm

1

30

0 ~ 40℃

10 ~90%

Sulfur dioxide (SO2)

ESO

GSE

0-10

0.04

<±0.05 ppm 0-0.5 ppm

<±10% 0.5-10ppm

0.01

60

0 ~ 40℃

15~90%

Sulfur dioxide (SO2)

ESP

GSE

0-100

0.4

<±0.5 ppm 0-5 ppm

<±10% 5-100ppm

0.1

30

0~40℃

15~90%

VOC

VM

GSS

0-25

0.1

<±0.1 ppm + 10%

0.1

60

0~40℃

10~90%

VOC

VP

GSS

0-500

1

<±5ppm + 10%

1

30

0~40℃

10 to 90%

VOC

PDL

PID

0-20

0.01

<±0.02ppm + 10%

0.01

30

0~40℃

0~95%

VOC

PDH

PID

0-1000

0.1

<±0.2ppm + 10%

0.1

30

0~40℃

0~95%


Attention:

1. Sensor types: Gas sensitive semiconductor (GSS), Gas sensitive electrochemistry (GSE), Non dispersive infrared (NDIR), photoionization detector (PID)

2. The accuracy is valid for the conditions described in the calibration certificate, excluding gas tolerance correction, and the relative error of the reading is%. The response time is the time (T90) when the reaction to a step change in gas concentration reaches 90% of the final reading. The actual response time will vary depending on gas exchange factors and concentration gradients.

3. The performance of the sensor will decrease beyond the described conditions to avoid condensation and damage to the sensor. The sensor will exhibit temperature and humidity interference, which will affect accuracy. Additional shell protection will expand the operating environment conditions, and contact points will gain further understanding of technology. Note that sensor design is intended to operate under conditions equivalent to the ambient air oxygen level.

4. Not all sensors can be used in conjunction with the 200, 300, and 500 series when in water and dust-proof enclosures (HH ENC). Please contact DianDian Technology for specific application suggestions.


The optional accessories are as follows:

AEROQUAL Series 300便携式气体检测仪

Place of Origin:New Zealand


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!