AVB
Anti short circuit PCB transformer
Mold, PRI 2 x 115 Vac, SEC 2 x 6 – 2 x 24 Vac, 0,35 – 3,2 VA
General data
Insulation material grade B
Protection level IP 00
Effectiveness up to 59%
The maximum ambient temperature is 70 ° C (AVB 3,2 maximum 50 ° C)
Measure output voltage 6-2 x 24 Vac
Measurement power: 0.35-3.2 VA
Measure input voltage 2 x 115 Vac
advantage
Suitable for high ambient temperatures
Mandatory short-circuit prevention
Ensure minimum specifications at high power
Series or parallel connection is also suitable for dual output voltage
Durable corrosion protection, high insulation value, and extremely high electrical reliability brought by the use of mold resin mold XtraDenseFill
Suitable for series or parallel dual input voltage
Self extinguishing mold material
standard
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
license
UL 5085-1/-2, CSA 22.2 No.66
application
As a power transformer used for matching voltage and simple electrical isolation.
A protective transformer used for safe electrical isolation of input and output terminals. By limiting the output voltage, this transformer is suitable for circuit construction of SELV and PELV.
Anti short circuit PCB transformer
Mold, PRI 2 x 115 Vac, SEC 2 x 6 – 2 x 24 Vac, 0,35 – 3,2 VA
General data
Insulation material grade B
Protection level IP 00
Effectiveness up to 59%
The maximum ambient temperature is 70 ° C (AVB 3,2 maximum 50 ° C)
Measure output voltage 6-2 x 24 Vac
Measurement power: 0.35-3.2 VA
Measure input voltage 2 x 115 Vac
advantage
Suitable for high ambient temperatures
Mandatory short-circuit prevention
Ensure minimum specifications at high power
Series or parallel connection is also suitable for dual output voltage
Durable corrosion protection, high insulation value, and extremely high electrical reliability brought by the use of mold resin mold XtraDenseFill
Suitable for series or parallel dual input voltage
Self extinguishing mold material
standard
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
The protection transformer complies with VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66
license
UL 5085-1/-2, CSA 22.2 No.66
application
As a power transformer used for matching voltage and simple electrical isolation.
A protective transformer used for safe electrical isolation of input and output terminals. By limiting the output voltage, this transformer is suitable for circuit construction of SELV and PELV.
variant | Measure input voltage | Measure output voltage | measured power |
AVB 0,35/2/6 | 2 x 115 Vac | 2 x 6 Vac | 0,35 VA |
AVB 0,35/2/9 | 2 x 115 Vac | 2 x 9 Vac | 0,35 VA |
AVB 0,35/2/12 | 2 x 115 Vac | 2 x 12 Vac | 0,35 VA |
AVB 0,35/2/15 | 2 x 115 Vac | 2 x 15 Vac | 0,35 VA |
AVB 0,35/2/18 | 2 x 115 Vac | 2 x 18 Vac | 0,35 VA |
AVB 0,35/2/24 | 2 x 115 Vac | 2 x 24 Vac | 0,35 VA |
AVB 0,5/2/6 | 2 x 115 Vac | 2 x 6 Vac | 0,5 VA |
AVB 0,5/2/8 | 2 x 115 Vac | 2 x 8 Vac | 0,5 VA |
AVB 0,5/2/9 | 2 x 115 Vac | 2 x 9 Vac | 0,5 VA |
AVB 0,5/2/12 | 2 x 115 Vac | 2 x 12 Vac | 0,5 VA |
AVB 0,5/2/15 | 2 x 115 Vac | 2 x 15 Vac | 0,5 VA |
AVB 0,5/2/18 | 2 x 115 Vac | 2 x 18 Vac | 0,5 VA |
AVB 0,5/2/24 | 2 x 115 Vac | 2 x 24 Vac | 0,5 VA |
AVB 1,0/2/6 | 2 x 115 Vac | 2 x 6 Vac | 1 VA |
AVB 1,0/2/9 | 2 x 115 Vac | 2 x 9 Vac | 1 VA |
AVB 1,0/2/12 | 2 x 115 Vac | 2 x 12 Vac | 1 VA |
AVB 1,0/2/15 | 2 x 115 Vac | 2 x 15 Vac | 1 VA |
AVB 1,0/2/18 | 2 x 115 Vac | 2 x 18 Vac | 1 VA |
AVB 1,0/2/24 | 2 x 115 Vac | 2 x 24 Vac | 1 VA |
AVB 1,5/2/6 | 2 x 115 Vac | 2 x 6 Vac | 1,5 VA |
AVB 1,5/2/8 | 2 x 115 Vac | 2 x 8 Vac | 1,5 VA |
AVB 1,5/2/9 | 2 x 115 Vac | 2 x 9 Vac | 1,5 VA |
AVB 1,5/2/12 | 2 x 115 Vac | 2 x 12 Vac | 1,5 VA |
AVB 1,5/2/15 | 2 x 115 Vac | 2 x 15 Vac | 1,5 VA |
AVB 1,5/2/18 | 2 x 115 Vac | 2 x 18 Vac | 1,5 VA |
AVB 1,5/2/24 | 2 x 115 Vac | 2 x 24 Vac | 1,5 VA |
AVB 2,0/2/12 | 2 x 115 Vac | 2 x 12 Vac | 2 VA |
AVB 2,3/2/6 | 2 x 115 Vac | 2 x 6 Vac | 2,3 VA |
AVB 2,3/2/8 | 2 x 115 Vac | 2 x 8 Vac | 2,3 VA |
AVB 2,3/2/9 | 2 x 115 Vac | 2 x 9 Vac | 2,3 VA |
AVB 2,3/2/12 | 2 x 115 Vac | 2 x 12 Vac | 2,3 VA |
AVB 2,3/2/15 | 2 x 115 Vac | 2 x 15 Vac | 2,3 VA |
AVB 2,3/2/18 | 2 x 115 Vac | 2 x 18 Vac | 2,3 VA |
AVB 2,3/2/24 | 2 x 115 Vac | 2 x 24 Vac | 2,3 VA |
AVB 3,2/2/6 | 2 x 115 Vac | 2 x 6 Vac | 3,2 VA |
AVB 3,2/2/9 | 2 x 115 Vac | 2 x 9 Vac | 3,2 VA |
AVB 3,2/2/12 | 2 x 115 Vac | 2 x 12 Vac | 3,2 VA |
AVB 3,2/2/15 | 2 x 115 Vac | 2 x 15 Vac | 3,2 VA |
AVB 3,2/2/18 | 2 x 115 Vac | 2 x 18 Vac | 3,2 VA |
AVB 3,2/2/24 | 2 x 115 Vac | 2 x 24 Vac | 3,2 VA |