VIP member
Agilent 1100HPLC Liquid Chromatography System
Second hand Aglient1100HPLC liquid chromatograph ● Standard manual second-hand liquid chromatograph Agilent 1100HPLC sampler (analytical or preparatio
Product details
Second hand liquid chromatography Agilent 1100HPLC
Product Introduction: | Second hand Aglient1100 HPLC liquid chromatograph |
Agilent 1100 series injection system with a complete range of varieties Standard manual sampler (analytical or preparation type) ● Standard automatic sampler Sample bottle capacity: up to 100 pieces (2mlx100) Injection volume: 0.1-100ul (0.1-1800ul) optional ● Micro disc automatic sampler Sample bottle capacity: 2x96 (orifice plate), 2x386 (orifice plate) or 100x2ml Injection volume: 0.1-100ul (standard part) 0.1-1500ul optional ● Micro standard automatic sampler/micro disc automatic sampler Injection volume: 0.01-8ul (standard); 0.01-40ul (optional) ● Constant temperature standard automatic sampler/micro disc automatic sampler Temperature range: 4-40 ℃ with adjustable step size of 1 ℃ 220 type microporous plate automatic sampler - combined chemical sample management system Sample bottle capacity: up to 12 microplates (96 well plate, 384 well plate) for various specifications of test tubes Injection volume: 0.1-5ul; 0.1-20ul Agilent 1100 series detectors Variable wavelength scanning ultraviolet detector (VWD) Wavelength range: 190? 600nm ● Multi wavelength detector (MWD) Wavelength range: 190? 950nm (dual light source) ● Diode Array Detector (DAD) Wavelength range: 190? 950nm (dual light source) Fluorescence detector (FID) Excitation wavelength: 200-700nm; Emission wavelength: 280-900nm Spectral storage: Full spectrum Differential Refraction Detector (RID) Temperature control: Room temperature 5 ℃ to 55 ℃ Built in automatic purge valve and automatic solvent circulation valve Electrochemical detector (ECD) LC/MS quadrupole mass detector (MSD) LC/MS ion trap mass detector (Trap MSD) Column temperature box and deaerator components |
|
Technical parameters: | |
Agilent 1100 liquid chromatograph The capillary liquid phase pump system controlled by an electronic flow control valve (EFC) has high accuracy and a wide flow rate range. The column flow rate range is 1-20ul/min; 10-100ul/min (optional) 0.001-2.5m/min (EFC closed state) High pressure preparation pump system, unit or dual high-pressure preparation pump Flow rate range: 0.001-100m1/min Analytical pump system Flow rate range: Unit pump: 0.001-10m3/min Binary pump: 0.001-5m3/min Four element pump: 0.001-10m3/min |
Product Introduction: | |
Agilent 1100 series injection system with a complete range of varieties Standard manual sampler (analytical or preparation type) ● Standard automatic sampler Sample bottle capacity: up to 100 pieces (2mlx100) Injection volume: 0.1-100ul (0.1-1800ul) optional ● Micro disc automatic sampler Sample bottle capacity: 2x96 (orifice plate), 2x386 (orifice plate) or 100x2ml Injection volume: 0.1-100ul (standard part) 0.1-1500ul optional ● Micro standard automatic sampler/micro disc automatic sampler Injection volume: 0.01-8ul (standard); 0.01-40ul (optional) ● Constant temperature standard automatic sampler/micro disc automatic sampler Temperature range: 4-40 ℃ with adjustable step size of 1 ℃ 220 type microporous plate automatic sampler - combined chemical sample management system Sample bottle capacity: up to 12 microplates (96 well plate, 384 well plate) for various specifications of test tubes Injection volume: 0.1-5ul; 0.1-20ul Agilent 1100 series detectors Variable wavelength scanning ultraviolet detector (VWD) Wavelength range: 190? 600nm ● Multi wavelength detector (MWD) Wavelength range: 190? 950nm (dual light source) ● Diode Array Detector (DAD) Wavelength range: 190? 950nm (dual light source) Fluorescence detector (FID) Excitation wavelength: 200-700nm; Emission wavelength: 280-900nm Spectral storage: Full spectrum Differential Refraction Detector (RID) Temperature control: Room temperature 5 ℃ to 55 ℃ Built in automatic purge valve and automatic solvent circulation valve Electrochemical detector (ECD) LC/MS quadrupole mass detector (MSD) LC/MS ion trap mass detector (Trap MSD) Column temperature box and deaerator components |
|
Technical parameters: | |
Agilent 1100 liquid chromatograph The capillary liquid phase pump system controlled by an electronic flow control valve (EFC) has high accuracy and a wide flow rate range. The column flow rate range is 1-20ul/min; 10-100ul/min (optional) 0.001-2.5m/min (EFC closed state) High pressure preparation pump system, unit or dual high-pressure preparation pump Flow rate range: 0.001-100m1/min Analytical pump system Flow rate range: Unit pump: 0.001-10m3/min Binary pump: 0.001-5m3/min Four element pump: 0.001-10m3/min |
Online inquiry