Wuhan Huaju Cold Refrigeration Electromechanical Co., Ltd
Home>Products>Air-cooled box type chiller unit
Air-cooled box type chiller unit
Energy saving economy: The digital electronic thermostat can accurately control the cold water temperature between+3 ℃ and 50 ℃, thereby controlling t
Product details

Air-cooled box type chiller unit

Product Description:

characteristic:The refrigeration heart adopts a fully sealed low-noise, low vibration, high-efficiency and energy-saving imported branded compressor. All electrical controls use imported branded components, and the heat exchanger adopts a shell and tube condenser with high heat transfer efficiency and easy cleaning and maintenance.

Energy saving economy:The digital electronic thermostat can accurately control the cold water temperature between+3 ℃ and 50 ℃, thereby controlling the normal operation of the unit and ensuring energy saving. All assembly, internal wiring, refrigerant filling, and debugging of the unit are completed in the factory. This model can be customized for both hot and cold use.

Safe operation:The machine is equipped with a compressor delay start protector, overcurrent relay, high and low voltage protector, fuse plug, and electronic time protection safety valve to ensure the normal operation of the unit.

Condenser:The air-cooled condenser adopts a steel tube aluminum sheet heat exchanger, designed and manufactured for single and multiple circuits, and the coil heat transfer area is larger than the general standard design. The surface wind speed is uniform, the heat transfer is stable, and the efficiency is long-lasting.

High efficiency threaded steel pipes are used, and the two end covers can be interchanged to change the direction of the water pipes. The water pipe process has multiple circuits, and each condenser is compatible with the compressor capacity. The straight through water pipe is easy to clean and maintain.

remarks:The whole machine can be customized according to process requirements, including explosion-proof chillers, acid resistant chillers, dual-purpose chillers, stainless steel food grade chillers, and supports foreign 60Hz-420v-480V voltage standards.

HJL-WFASpecification parameters of air-cooled box type chiller (I)/SPECIFICACATIONS

parameterParameter

modelModel

1/2WFA

01WFA

02WFA

03WFA

04WFA

05WFA

06WFA

08WFA

Refrigeration capacity
Cooling Capacity

Kw
50Hz/60Hz

1.53
1.79

2.94
3.44

5.67
6.63

8.39
9.82

10.9
12.75

13.95
16.32

16.9
19.77

21.8
25.51

Kcal/h
50Hz/60Hz

1316
1540

2528
2958

4872
5701

7216
8442

9374
10968

11990
14028

14530
17000

18748
21935

total input power
Total input

KW

0.68

1.31

2.6

3.6

4.5

5.5

6.6

8.6

Maximum operating current
Maximum Running Current

A

4.1

8

15.8

8.8

10.9

13.4

16

20.9

power supplyPower Supply

Volt

1N-220V 50Hz/60Hz

3N-380V/415V 50Hz/60Hz

refrigerantRefrigerant

nameName

R22

ChargeFill

Kg

0.6

0.8

1.8

2.7

3.5

4.3

5

3.5x2

Control methodcontrol type

capillaryCapillary Tube

compressorCompressor

typeType

Fully enclosed rotary type
Hermetic Rotary

Fully rotating or piston type enclosed vortex
Hermetic Scroll or Piston

powerMotor

Kw

0.55

0.75

1.5

2.25

3

3.75

4.5

3x2

Cooling air volumeAir Flow

m3/h

800

1000

2000

3000

4000

5000

6000

8000

chilled waterChilled
Water

amount of waterFlow

m3/h

0.26
0.31

0.51
0.59

0.97
1.14

1.44
1.68

1.87
2.19

2.4
2.81

2.91
3.41

3.75
4.39

water tankTank

m3

0.022

0.028

0.038

0.038

0.065

0.065

0.11

0.11

Inlet and outlet pipe diameter
In/Out pipe size

G1/2'

G1/2'

G3/4'

G3/4'

G3/4'

G1'

G1'

G1'-1/2'

water pumpPump

powerMotor

Kw

0.375

0.375

0.55

0.55

0.55

0.75

0.75

0.75

pressurePressure

KPa

180

180

250

242

242

290

290

290

External dimensions
Dimension

longLength

mm

600

600

820

945

945

1035

1200

1470

wideWidth

mm

400

400

460

550

550

610

650

710

tallHeight

mm

940

940

1170

1370

1370

1385

1480

1700

weightWeight

Kg

45

60

120

130

160

170

250

270

Remarks:

1.The cooling system is based on the inlet temperature of ice water12,Export temperature7;Cooling air inlet temperature35℃, outlet temperature40Calculated at ℃.

Note:

1.Nominal cooling capacity conditions: chilled water in 12, out7; cooling water in 35, out40.

2.If there are any changes to the catalog specifications,No further notice will be given.

2.Specifications are subject to change without notice for further improvement.

HJL-WFASpecification parameters of air-cooled box type chiller (II)/SPECIFICACATIONS

parameterParameter

modelModel

10WFA

12WFA

H15WFA

20WFA

25WFA

30WFA

40WFA

50WFA

60WFA

Refrigeration capacity
Cooling Capacity

Kw
50Hz/60Hz

28.01
32.78

33.79
39.53

44.15
51.65

59.08
69.12

71.72
83.91

87.2
102.02

113.58
132.89

135.49
158.52

181.68
218.02

Kcal/h
50Hz/60Hz

24089
28184

29059
33999

37965
44419

50805
59442

61683
72169

74992
87741

97675
114280

116521
136330

156249
187499

total input power
Total input

KW

11

13.3

17

22.8

27.7

33.7

42.8

51.1

68.8

Maximum operating current
Maximum Running Current

A

26.7

32.3

41.3

55.4

63.1

76.8

97.5

116.5

143.1

power supplyPower Supply

Volt

3N-380V/415V 50Hz/60Hz

refrigerant
Refrigerant

nameName

R22

ChargeFill

Kg

4.3x2

5x2

6.5x2

8.5x2

10.5x2

12.5x2

17x2

20.5x2

24.9x2

Control method
control type

capillary
Capillary Tube

External balanced thermal expansion valve
With hermetic gyral or piston

compressor
Compressor

type
Type

Fully enclosed vortex or piston type
With hermetic gyral or piston

powerMotor

Kw

3.75x2

4.5x2

5.5x2

7.5x2

9.4x2

11.3x2

15x2

18.8x2

22.5x2

Cooling air volumeAir Flow

m3/h

10000

12000

15000

20000

25000

30000

40000

48000

66000

chilled water
Chilled
Water

amount of waterFlow

m3/h

4.82
5.64

5.81
6.8

7.6
8.89

10.16
11.89

12.34
14.44

15
17.55

19.53
22.85

23.3
27.27

30.52
36.63

water tankTank

m3

0.188

0.188

0.285

0.285

0.405

0.405

0.61

0.61

0.7

Inlet and outlet pipe diameter
In/Out pipe size

G1-1/2'

G1-1/2'

G2'

G2'

G2-1/2'

G2-1/2'

G3'

G3'

G3'

water pump
Pump

power
Motor

Kw

1.5

1.5

1.5

2.2

2.2

4

4

4

4

pressurePressure

KPa

205

205

205

220

220

250

250

250

250

External dimensions
Dimension

longLength

mm

1475

1460

1800

1960

2080

2080

2300

2300

3556

wideWidth

mm

715

800

890

940

1000

1000

1220

2200

2200

tallHeight

mm

1695

1780

1880

1960

2055

2055

2310

2210

2210

weightWeight

Kg

350

370

520

590

790

880

1100

1280

1420

Note:

1.The measurement conditions for the above specification parameter capabilities are: chilled water inlet temperature of 12 ℃, outlet temperature of 7 ℃, cooling air inlet temperature of 35 ℃, outlet air temperature of 40 ℃, and fouling coefficient of 0.0001m2. c \ \ w;

2.The above specifications may change due to product improvements without prior notice. If there are special requirements, please specify them before placing an order

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!