Shanghai Ziyi Automation Instrument Co., Ltd
Home>Products>sheath thermocouple
sheath thermocouple
sheath thermocouple
Product details

ZY Armored Thermocouple
Product features:
● Less thermal response time, reducing dynamic errors;
● Flexible installation and use;
● Large measurement range;
High mechanical strength and good pressure resistance.
sheath thermocoupleDetailed information:



sheath thermocouple

application
Usually used in conjunction with display instruments, recording instruments, etc. Directly measure the temperature of liquid, vapor, gas media, and solid surfaces within the range of 0-1300 ℃ in various production processes.
characteristic
● Less thermal response time, reducing dynamic errors;
● Flexible installation and use;
● Large measurement range;
High mechanical strength and good pressure resistance.
Working principle
sheath thermocoupleThe two electrodes are composed of different conductor materials. When there is a temperature difference between the measuring end and the reference end, a thermoelectric potential is generated, and the working instrument displays the temperature value corresponding to the thermoelectric potential.
Main technical parameters
● Product execution standards
IEC584 IEC1515 GB/T16839-1997 JB/T5582-91
● Room temperature insulation resistance
Armored tropical dollAt an ambient temperature of 20 ± 15 ℃, relative humidity not exceeding 80%, and a test voltage of 500 ± 50V (DC), the insulation resistance between the electrode and the outer sleeve is ≥ 1000M Ω. m. The insulation resistance of a 1m long sample is 1000M Ω; The insulation resistance of a 10m long sample is 100M Ω.
● Temperature measurement range and allowable deviation
点击看大图
● Temperature measurement range and allowable deviation
model Graduation Allowable error and material grade
Level I class ii
Allowable deviation Temperature measurement range ℃ Allowable deviation Temperature measurement range ℃
WRNK K ±1.5℃ -40~+375 ±2.5℃ -40~+333
±0.004│t│ 375~1000 ±0.0075│t│ 333~1200
WRMK N ±1.5℃ -40~+375 ±2.5℃ -40~+333
±0.004│t│ 375~1000 ±0.0075│t│ 333~1200
WREK E ±1.5℃ -40~+375 ±1.5℃ -40~+333
±0.004│t│ 375~800 ±0.004│t│ 333~900
WRFK J ±1.5℃ -40~+375 ±1.5℃ -40~+333
±0.004│t│ 375~750 ±0.004│t│ 333~750
WRCK T ±1.5℃ -40~+125 ±1℃ -40~+333
±0.004│t│ 125~350 ±0.0075│t│ 133~350
WRPK S ±1℃ 0~+1100 ±2.5℃ 0~600
±[1+0.003(t-1100)] 1100~1600 ±0.0025│t│ 600~1600
Temperature measurement range and allowable deviation
Code and size
Outer diameter of armor doll
Φ8
Φ6
Φ5
Φ4
Φ3
Φ2
M
M16×1.5
M12×1.5
S
22
19
点击看大图
Code and size
Outer diameter of armor doll
Φ8
Φ6
Φ5
Φ4
Φ3
Φ2
D
Φ60
Φ50
D0
Φ42
Φ36
D1
Φ24
Φ20
S
22
19
d0
Φ9
Φ7
点击看大图
点击看大图
Anti spray type
点击看大图
Waterproof type

点击看大图
Flat plug-in type
点击看大图
Circular plug-in type
点击看大图
Handle type
点击看大图
Compensation wire type
sheath thermocoupleRecommended temperature for use
variety
Sleeve Material
Outer diameter (mm)
Operating temperature (℃)
Long term use temperature
Short term usage temperature
Armored nickel chromium nickel silicon
1Cr18Ni9Ti
2.0
600
700
3.0,4.0,5.0,6.0,8.0
800
900
GH3030
2.0,3.0
800
900
4.0,5.0
900
1000
6.0,8.0
1000
1100
Armored nickel chromium silicon nickel silicon
1Cr18Ni9Ti
2.0
600
700
GH3030
3.0,4.0,5.0,6.0,8.0
800
900
2.0,3.0
900
1000
4.0,5.0
1000
1100
GH3039
6.0.8.0
1100
1200
2.0,3.0,4.0
1000
1100
5.0.6.0.8.0
1100
1200
Armored nickel chromium copper nickel
1Cr18Ni9Ti
2.0
500
600
3.0.4.0.5.0
600
700
6.0.8.0
700
800
Armored Iron Copper Nickel
1Cr18Ni9Ti
2.0
400
500
3.0.4.0.5.0
500
600
Armored copper copper nickel
1Cr18Ni9Ti
6.0.8.0
600
700
2.0,3.0.4.0.5.0
250
300
Armored Platinum Rhodium 10 Platinum
GH3039
6.0.8.0
300
350
2.0.3.0.4.0.
5.0.6.0.8.0
1000
1100
1100
1200
Additional device form

Hoop type
Thermal block type
Model naming method
W Temperature instrument

|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
R thermocouple
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Index number of temperature sensing element material
M
N
E
F
C
P
Q
R
Nickel chromium silicon nickel silicon N
Nickel chromium nickel silicon K
Nickel chromium copper nickel E
Iron Copper Nickel J
Copper Copper Nickel T
Platinum rhodium 10 platinum S
Platinum rhodium 13 platinum R
Platinum rhodium 30- Platinum 6B
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K
Armored type
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Even number of threads
not have
2
Single tube
Double branch

|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Installation fixed form
1
2
3
4
5
No fixed device
Fixed card sleeve thread
Activity card sleeve thread
Fixed card sleeve flange
Activity card sleeve flange
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Form of junction box
2
3
6
7
8
9
Anti spray type
Waterproof type
Circular plug-in type
Flat plug-in type
Handle type
Compensation wire type
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Workplace format
1
2
Insulated type
Shell type
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Additional device form
M
G
Contact block type
Hoop type
|
|
|
|
|
|
|
|
|
|
|
W R N K 2 - 2 3 1 M Typical Model Example
Selection Notice
1) Model number
2) Dividing number
3) Accuracy level
4) Installation fixed form
5) Material of protective tube
6) Length or insertion length
Example A:sheath thermocouple, K-type, Class I, fixed sleeve thread, protective tube GH3030, length 450mm, insertion length 300mm, WRNK-231, K, L × l=450 × 300, Class I, protective tube GH3030.
Model and specifications
temperature-sensing element
name
model
Graduation
specifications
Workplace format
d L1
Single Platinum Rhodium 10 Platinum
WRPK-101
S
Φ2
Φ3
Φ4
Φ5
Φ6
Φ8
75
100
150
200
250
300
400
500
750
1000
2000
3000
4000
5000
7500
10000
15000
20000
25000
Insulated type
WRPK-102 Shell type
Double platinum rhodium 10 platinum
WRPK2-101
Insulated type
WRPK2-102 Shell type
Single nickel chromium silicon nickel silicon
WRMK-101
N
Insulated type
WRMK-102 Shell type
Double branch nickel chromium silicon nickel silicon
WRMK2-101
Insulated type
WRMK2-102 Shell type
Single nickel chromium nickel silicon
WRNK-101
K
Insulated type
WRNK-102 Shell type
Double branch nickel chromium nickel silicon
WRNK2-101
Insulated type
WRNK2-102 Shell type
Single nickel chromium nickel silicon
WREK-101
E
Insulated type
WREK-102 Shell type
Single nickel chromium copper nickel
WREK2-101
Insulated type
WREK2-102 Shell type
Single copper copper nickel WRCK-101 T
Insulated type
WRCK-102 Shell type
Double copper copper nickel WRCK2-101
Insulated type
WRCK2-102 Shell type
Single iron copper nickel
WRFK-101
J
Insulated type
WRFK-102 Shell type
Double iron copper nickel
WRFK2-101
Insulated type
WRFK2-102 Shell type




Online inquiry