Product details

1、 Product Overview:
The automatic balance recorder is produced using years of accumulated experience, the latest electronic technology, and precision machinery. There are nine hundred models to choose from according to various combinations, with recording methods including single stroke, double stroke, triple stroke, and pen writing, as well as line marking from 6 to 12 o'clock and 24 o'clock; The adjustment methods include 2-position, 3-position, and PID, while the alarm methods include upper limit, upper limit, and upper/lower limit. By combining these, high-quality recorders that users are eagerly anticipating can be provided.
Automatic balance recorder is a highly sensitive electronic automatic balance recorder. Its effective recording format is 250mm. According to the number of recorded strokes, there are four models: single stroke, double stroke, triple stroke, and quadruple stroke. This instrument has the characteristics of high precision, high sensitivity, high pen speed, high reliability, and modular components. The automatic balance recorder can not only serve as a single recording device, but also as a backup testing recording device.
2、 Automatic balance recorder parameters:
Input signal: mV - DC3 mV or above, thermal resistance -30 ℃ or above (Pt100)
Scale length: 180mm
Indication accuracy: ± 0.5% of input range
Indication hysteresis: 0.25% of input range
Balance time: Input range shifts by approximately 2 seconds (50Hz)
Single stroke, multi-point

E
H
1) Thermocouple type
2) Thermal resistance type
8) Millivolt type
9) Current type
26) Upper (or lower) limit alarm
36) Upper and lower limit alarms
27) Multiple points with two fixed positions for adjustment
28) Multiple fixed upper limit alarms
37) Adjust three positions at each point
38) Multiple points with set upper and lower limits for alarm
21) Two position adjustment
32) Three position adjustment (single stroke only)
00) Record
61) PID switch shape (single pen only)
62) PID servo shape (single pen only)
63) PID current waveform (single pen only)
01) Single transaction
06) Six o'clock
12) At twelve o'clock
24) 24:00