RPP-BSD automatic closed flash point tester
1.Scope of application:
Suitable for determining the content of petroleum products inGB/T 261-2008Under standard conditions, when the mixture of steam and air heated to it comes into contact with a flame and flashesCritical temperature, i.e. the closed cup method for determining the flash point of petroleum products.
The standard specifies the use of Binsky-The Martin closed flash point tester is used to determine the flash point of flammable liquids, liquids with suspended particles, liquids that tend to form a film on the surface under test conditions, and other liquids. This standard is applicable to flash points higher than40℃The sample.
Applicable standards:GB/T261-2008Determination of flash point Binsky Martin's closed cup method,ASTM D93
2.technical parameter:
RPP-BSDAutomatic flash point testerIt is the latest fully automatic analytical instrument developed by our company. The instrument adopts a mechanical arm structure, which truly realizes one click operation and improves work efficiency. Design strictly in accordance with national standardsGB/T261-2008Conduct experiments, or follow the instructions providedASTM D93Standard execution. Binsky-The Martin closed flash point tester is used to determine the flash points of flammable liquids, liquids with suspended particles, liquids that tend to form a film on the surface under test conditions, and other liquids. Suitable for flash points higher than40Samples at ℃. The instrument adopts high precisionPt100Temperature sensor and flash point detector, electronic ignition. The software has complete functions. And it has multiple protection functions to prevent accidents, and the instrument can be directly connectedLIMSSystem. If you need to print the test results, you can choose the corresponding printer for printing.
3.Performance characteristics:
1) Industrial computer control,7Inch high brightnessTFTLCD display screen, four wire resistive touch screen
2) Automatic lifting and lowering of oil cup cover assemblyAutomatic ignition and flash point capture, automatic stirring, lid opening, automatic fault protection, automatic printing of test results (with optional printer), automatic cooling, automatic detection and correction of atmospheric pressure results
3) Flash point detection: thermocouple detection
4) Data storage: Micro hard disk storage is larger than1000Group data
5) Temperature measurement:Pt100
6) Test temperature: Room temperature~400℃
7) Temperature accuracy:0.1℃
8) Heating rate control5-6℃/min、1-1.5℃/min;
9) Repeatability: ≤2℃;
10)Reproducibility: ≤4℃;
11)Mixing method: A:90to120rpm, B:250±10rpm
12)Heating power:400W
13)Cooling method: Strong wind cooling
14)Ignition method:Optional gas ignition and electronic ignition
15)data input/Output:RS232CConnection standards.Can be connectedLIMSsystem
16)Printer output:USB2.0
17)automatic alarm:After the experiment is completed, the instrument will automatically sound an alarm, indicating to the operator that the experiment has ended; Error alarm
18)Power interface:220V 50Hz
19)Other interfaces: connectableUSB2.0Interface standard mouse and keyboard
20)Calibrate the instrument using standard oil
21)Automatic atmospheric pressure flash point temperature calibration, automatic atmospheric pressure detection
22)External dimensions:490*280*580 mm