Taizhou Zhonghuan Analytical Instrument Co., Ltd
Home>Products>Automatic tube bending kinematic viscometer
Automatic tube bending kinematic viscometer
Brief description: RPP-ND200 automatic tube bending kinematic viscosity meter is an automated instrument for quickly measuring the kinematic viscosity
Product details
Details Introduction

performance index

According to the standard:ASTM D7279D445D446NB/SH/T 0956-2017T/CEC 127-2016The measurement results meet and are superior toGB/T265Standard requirements.

Measurement range:0.36000mm2/sThe measurement span of two viscosity tubes is100times

Sample dosage:0.31 mL

Bath capacity:5.5 L

Temperature control range:20100℃ (target temperature below)40Need to prepare a separate cooler)

Temperature control accuracy:0.01

Timing accuracy:0.01 S

Repeatability:≤0.5%

Whole machine power:≤1200 W

Host size:450×500×580mm

work environment

Working power supply:AC220V±10% 50Hz±10%

Environmental temperature:1028

Relative humidity:80%RH

his He: There is no strong vibration, airflow, strong electromagnetic interference, or corrosive gas around the laboratory.

Instrument features

1Fast measurement speed. The fastest1The results are usually obtained in minutes35Results will be available in minutes. The entire process of injection, measurement, cleaning, drying, and result calculation generally does not exceed10minute.

2High degree of automation. Measurement, cleaning, drying, result calculation, and repeatability calculation are all automatically completed.

3There are many types of samples for measurement. It can measure both transparent and opaque samples, including Newtonian liquids such as gasoline, diesel, kerosene, cutting fluid, new lubricating oil, and in use oil.

4Accurate measurement data.The instrument has a secondary precise quantification function, automatically cutting the sample liquid column, accurately controlling the sample volume, no longer relying on micro pipettes for quantification, avoiding the limitations and deviations of pipette quantification, and ensuring accurate data.

5Automatic dual solvent cleaning, fast cleaning, low cleaning cost. A cleaning process generally consumes no more than cleaning solution20milliliter.

6Multiple auxiliary functions. Includes: constant calibration, temperature calibration, internal clock timing verification, automatic calculation of viscosity index, and kinematic viscosity-Enzhi viscosity automatic conversion, repeatability automatic calculation.

7Dual over temperature protection for software and hardware, over temperature alarm, and anti dry burn protection function.

8The temperature rise and fall speed is fast. The fastest temperature rise and fall rate is5/minute.

9Adopting a double-layer glass cylinder, the temperature is more uniform.

10AdoptingPT500High precision temperature sensor, stable and accurate temperature in the constant temperature bath, with temperature control accuracy reaching0.01℃.

11Can be equipped with disposable filters, greatly reducing the workload of experimental personnel in sample pretreatment.

12The viscometer can be quickly replaced without the need to empty the constant temperature bath.

13, can be done throughWIFIWireless data transmission, connectionLIMSSystem.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!