AvaSpec-ULS2048XL-EVO High UV Near Infrared Sensitivity Back Illumination CCD Spectrometer
AvaSpec-ULS2048XL-EVO is a fiber optic spectrometer that successfully combines high quantum efficiency and high measurement speed. Unlike other back illuminated CCD detectors that use a planar array, the AvaSpec-ULS2048XL-EVO spectrometer uses a linear array large-sized pixel detector (14 × 500 μ m), which has very high efficiency in both ultraviolet (200-400nm) and near-infrared (950-1160nm). The AvaSpec-ULS2048XL-EVO spectrometer is also equipped with an electronic shutter, allowing for an integration time of up to 2 microseconds. To further increase sensitivity, there is also a sensitivity enhancement lens option that can increase sensitivity by 60% when used with large core diameter fibers.
technical data
Spectrometer model |
AvaSpec-ULS2048XL-EVO |
optical table |
symmetryCzerny-Turner, focal length75mm |
wavelength range |
200 – 1160 nm |
Resolution(FWHM) |
0.09 –20 nm, depending on the spectrometer configuration |
stray |
< 0.5% |
sensitivity |
460,000(Unit: Count)/Micro watt integration time per millisecond |
UV quantum efficiency |
60% (200-300nm) |
detector |
CMOS2048pixelCCDlinear array |
Signal to Noise Ratio |
525:1 |
ADconverter |
16 bit, 1 MHz |
integration time |
2us–20s |
communication interface |
USB 3.0High speed,5 GbpsGigabit Ethernet1 Gbps |
Sample Rate |
2.44 ms / scan |
Readout Noise |
9.8 cnt RMS |
dark noise |
4.5 cnt RMS |
dynamic range |
13,700 |
Data transmission speed |
2.44 ms / scan (USB3) |
digitI/Ointerface |
HD-26Connector,2An analog input,2An analog output,3Input a number,12Number output, trigger, synchronize |
Power requirements |
defaultUSBPower Supply,700 mAOr external12VDC,360 mA |
Dimensions and weight |
175 x 127 x 44.5 mm(Single channel), 1180g |
Grating selection table
Application scope | Available wavelengths | Spectral range (nm) | Number of grating lines/mm | Sparkling wavelength (nm) | Grating model |
UV/VIS/NIR | 200-1160** | 960** | 300 | 300 | UA |
UV/VIS/NIR | 200-1160** | 900** | 300 | 300/1000 | UNA-DB |
UV/VIS | 200-850 | 520 | 600 | 300 | UB |
UV | 200-750 | 250-220* | 1200 | 250 | UC |
UV | 200-650 | 165-145* | 1800 | UV | UD |
UV | 200-580 | 115-70* | 2400 | UV | UE |
UV | 200-400 | 70-45* | 3600 | UV | UF |
UV/VIS | 250-850 | 520 | 600 | 400 | BB |
VIS/NIR | 300-1160** | 860** | 300 | 500 | VA |
VIS | 360-1000 | 500 | 600 | 500 | VB |
VIS | 300-800 | 250-200* | 1200 | 500 | VC |
VIS | 350-750 | 145-100* | 1800 | 500 | VD |
VIS | 350-640 | 75-50* | 2400 | VIS | VE |
NIR | 500-1050 | 500 | 600 | 750 | NB |
NIR | 500-1050 | 220-150* | 1200 | 750 | NC |
NIR | 600-1160 | 350-300 | 830 | 800 | SI |
NIR | 600-1160** | 560** | 300 | 1000 | IA |
NIR | 600-1160 | 500 | 600 | 1000 | IB |
*Depends on the starting wavelength of the grating; The higher the wavelength, the greater the dispersion, and the smaller the selection range** Please note that not all 2048 pixels will be used for the available range.
Resolution Table of Spectrometer
Slit width (μ m) | ||||||
Logarithms of grating lines (lines/mm) | 10 | 25 | 50 | 100 | 200 | 500 |
300 | 1.4 | 1.5 | 2.5 | 4.8 | 9.2 | 21.3 |
600 | 0.70-0.80* | 0.75-0.85* | 1.2 | 2.4 | 4.6 | 10.8 |
830 | 0.42-0.48* | 0.50-0.58* | 0.93 | 1.7 | 3.4 | 8.5 |
1200 | 0.25-0.31* | 0.37-0.43* | 0.52-0.66* | 1.1 | 2.3 | 5.4 |
1800 | 0.17-0.21* | 0.26-0.32* | 0.34-0.42* | 0.8 | 1.6 | 3.6 |
2400 | 0.12-0.18* | 0.18-0.24* | 0.26-0.34* | 0.44-0.64* | 1.1 | 2.7 |
3600 | 0.09-0.12* | 0.11-0.15* | 0.19 | 0.4 | 0.8 | 1.8 |
*Depends on the starting wavelength of the grating; The higher the wavelength, the greater the dispersion, and the smaller the range of choices.
ordering information
AvaSpec-ULS2048XL-EVO | 75mm AvaBench, 2048 large 500 μ m pixel back thin CCD detector, USB power supply, high-speed USB3 and ETH interface, including AvaSoft Basic, USB interface cable. Specify grating, wavelength range, and options. |
PS-12V / 1.0A | The external power required to run in ETH mode. |