Shanghai Huanao Technology Co., Ltd
Home>Products>BINDER KB53 Low Temperature Incubator
BINDER KB53 Low Temperature Incubator
BINDER KB53 Low Temperature Incubator
Product details

BINDER KB53 Low Temperature Incubator

1、 Product Introduction:

1. Temperature range: -5 ℃ to 100 ℃

2 APT.line ™ Internal preheating technology

3. Compared to the previous generation product, it can save up to 30% energy consumption

4. Cooling through a compression cooler

5. Adjustable fan speed

6. Controller using interval programming and real-time programming

7. Interior door made of safety glass (ESG)

8. Two sockets made of stainless steel

9. Stackable

10. Independent adjustable temperature safety device, Class 3.1 (DIN 12880), equipped with optical and sound alarms

11. Computer interface: Ethernet

2、 Technical parameters:

PRODUCT MODEL KB053-230V1 KB053UL-120V1
Choose a model standard standard
Item code 9020-0199 9020-0302
measure
Internal volume [L] 53 53
Net weight of equipment (unloaded) [kg] 78 78
Maximum total load [kg] 40 40
Maximum load per partition [kg] 15 15
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 635 635
Net weight at height [mm] 835 835
Depth net weight [mm] 580 580
Wall distance from rear [mm] 100 100
Wall to side distance [mm] 100 160
Internal dimensions
Width [mm] 400 400
Height [mm] 400 400
Depth [mm] 330 330
The number of doors
Inner door 1 1
Outer door 1 1
Data related to the environment
Energy consumption at 37 ℃ [Wh/h] 70 70
Sound pressure level [dB (A)] 49 49
firmware
Number of partitions (hours/maximum) 2/4 2/4
Temperature performance data
Temperature range [℃] -5…100 -5…100
The temperature deviation is 37 ℃ [± K] 0.2 0.2
Temperature fluctuation at 37 ℃ [± K] 0.1 0.1
Heating time to 37 ℃ [min] 5 5
The recovery time after opening the door in 30 seconds is 37 ℃ [min] 2 2
Electric data
Rated voltage [V] 230 120
Power frequency [Hz] 50 60
Rated power [kW] 0.6 0.6
Equipment safety device [A] 10 12.5
Phase (rated voltage) 1~ 1~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.