BINDER KBF P 240 Constant Temperature and Humidity Chamber
1、 Product Introduction:
1. Temperature range: 0 ℃ to 70 ℃
2. Temperature range with illumination: 10 ℃ to 60 ℃
3. Humidity range: 10% relative humidity to 80% relative humidity
4. 2 variable positioning lighting boxes with UV/Vis illumination that meets ICH requirements
5 APT.lineTMPreheating chamber technology
6. Using capacitive humidity sensors and steam humidification for humidity regulation
7. The interior is entirely made of stainless steel
8. Intuitive touch screen controller using interval programming and real-time programming
9. Internal data logger and open format measurement values can be read through USB
10. Equipment self-test is used for comprehensive status analysis
11. The sealed inner door is made of safety glass (ESG)
12. Preventing corrosion of glass through special TIMELESS coating
13. Two sockets made of stainless steel
14. Access hole with silicone plug 30mm, left
15. 4 stable casters, 2 with brakes
16. Independently adjustable temperature safety device Class 3.1 (DIN 12880), equipped with optical and acoustic temperature alarms
17. Computer interface: Ethernet
18. Door heating
2、 Technical parameters:
PRODUCT MODEL | KBFP240-230V1 | KBFP240UL-240V1 |
Choose a model | standard | standard |
Item code | 9020-0328 | 9020-0329 |
measure | ||
Internal volume [L] | 247 | 247 |
Net weight of equipment (unloaded) [kg] | 213 | 213 |
Maximum total load [kg] | 100 | 100 |
Maximum load per partition [kg] | 30 | 30 |
The dimensions of the casing do not include additional components and connectors | ||
Net weight width [mm] | 925 | 925 |
Net weight at height [mm] | 1460 | 1460 |
Depth net weight [mm] | 800 | 800 |
Wall to side distance [mm] | 100 | 100 |
Wall distance from rear [mm] | 100 | 100 |
Internal dimensions | ||
Width [mm] | 650 | 650 |
Height [mm] | 785 | 785 |
Depth [mm] | 485 | 485 |
The number of doors | ||
Inner door | 1 | 1 |
Outer door | 1 | 1 |
Data related to the environment | ||
Energy consumption at 40 ℃ and 75% relative humidity [Wh/h] | 760 | 760 |
Sound pressure level [dB (A)] | 53 | 53 |
firmware | ||
Number of partitions (hours/maximum) | 2/7 | 2/7 |
Number of Lighting Boxes (Standard/Maximum) | 01 | 01 |
firmware | ||
Number of Lighting Boxes (Standard/Maximum) | 2/2 | 2/2 |
Temperature performance data | ||
Temperature range without lighting box [℃] | 0…70 | 0…70 |
Temperature range with 100% illumination [℃] | 10…60 | 10…60 |
The maximum thermal compensation is at 40 ℃ [W] | 400 | 400 |
Climate performance data | ||
Temperature range with 100% illumination [℃] | 10…60 | 10…60 |
Temperature range without lighting box [℃] | 10…70 | 10…70 |
Temperature deviation with illumination, at 40 ℃ and 75% relative humidity [± K] | 0.6 | 0.6 |
Temperature deviation with illumination, at 25 ℃ and 60% relative humidity [± K] | 0.6 | 0.6 |
Temperature fluctuation with illumination, at 25 ℃ and 60% relative humidity [± K] | 0.2 | 0.2 |
Temperature fluctuation with illumination, at 40 ℃ and 75% relative humidity [± K] | 0.2 | 0.2 |
Humidity range with lighting box, with lighting [% relative humidity] | 10…75 | 10…75 |
Humidity range without lighting box [% relative humidity] | 10…80 | 10…80 |
Humidity fluctuation with illumination, at 40 ℃ and 75% relative humidity [± relative humidity] | 2 | 2 |
Humidity fluctuation with illumination, at 25 ℃ and 60% relative humidity [± relative humidity] | 1.5 | 1.5 |
The humidity recovery time after opening the door in 30 seconds is at 40 ℃ and 75% relative humidity, with lighting [min] | 6 | 6 |
The humidity recovery time after opening the door in 30 seconds is at 25 ℃ and 60% relative humidity, with lighting [min] | 4 | 4 |
Lighting data for each lighting box | ||
ICH compliant lighting (visible light) [lx]* | 7500 | 7500 |
ICH compliant illumination (UV light) [W/m2]* | 1.1 | 1.1 |
Electric data | ||
Rated voltage [V] | 200…230 | 200…240 |
Power frequency [Hz] | 50/60 | 50/60 |
Rated power [kW] | 2.4 | 2.4 |
Equipment safety device [A] | 16 | 16 |
Phase (rated voltage) | 1~ | 1~ |
1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes* The average value measured under the illumination box using a spherical sensor (± 10%) 12 cm at 25 ℃. The measurement unit is W/m2, which involves total radiation.