BINDER KBF240 Constant Temperature and Humidity Chamber
1、 Product Introduction:
1. Temperature range: 0 ℃ to 70 ℃
2. Humidity range: 10% relative humidity to 80% relative humidity
3 APT.lineTMPreheating chamber technology
4. Using capacitive humidity sensors and steam humidification for humidity regulation
5. Intuitive touch screen controller using interval programming and real-time programming
6. Internal data logger and open format measurement values can be read through USB
7. Equipment self-test is used for comprehensive status analysis
8. The sealed inner door is made of safety glass (ESG)
9. Prevent corrosion of glass through a special TIMELESS coating.
10. The interior is entirely made of stainless steel
11. A bracket made of stainless steel
12. Access hole with silicone plug 30mm, left
13. 4 stable casters, 2 with brakes, starting from 240 liters
14. Independently adjustable temperature safety device Class 3.1 (DIN 12880), equipped with optical and acoustic temperature alarms
15. Computer interface: Ethernet
16. Door heating
2、 Technical parameters:
PRODUCT MODEL | KBF240-230V1 | KBF240UL-240V1 |
Choose a model | standard | standard |
Item code | 9020-0322 | 9020-0323 |
measure | ||
Internal volume [L] | 247 | 247 |
Net weight of equipment (unloaded) [kg] | 184 | 184 |
Maximum total load [kg] | 100 | 100 |
Maximum load per partition [kg] | 30 | 30 |
The dimensions of the casing do not include additional components and connectors | ||
Net weight width [mm] | 925 | 925 |
Net weight at height [mm] | 1460 | 1460 |
Depth net weight [mm] | 800 | 800 |
Wall to side distance [mm] | 100 | 100 |
Wall distance from rear [mm] | 100 | 100 |
Internal dimensions | ||
Width [mm] | 650 | 650 |
Height [mm] | 785 | 785 |
Depth [mm] | 485 | 485 |
The number of doors | ||
Inner door | 1 | 1 |
Outer door | 1 | 1 |
Data related to the environment | ||
Energy consumption at 40 ℃ and 75% relative humidity [Wh/h] | 650 | 650 |
Sound pressure level [dB (A)] | 52 | 52 |
firmware | ||
Number of partitions (hours/maximum) | 2/9 | 2/9 |
Temperature performance data | ||
Temperature range [℃] | 0…70 | 0…70 |
Temperature deviation at 40 ℃ [± K] | 0.3 | 0.3 |
Temperature fluctuation [± K] | 0.1 | 0.1 |
The maximum thermal compensation is at 40 ℃ [W] | 300 | 300 |
Climate performance data | ||
Temperature range [℃] | 10…70 | 10…70 |
Temperature deviation at 40 ℃ and 75% relative humidity [± K] | 0.3 | 0.3 |
Temperature deviation at 25 ℃ and 60% relative humidity [± K] | 0.3 | 0.3 |
Temperature fluctuation at 40 ℃ and 75% relative humidity [± K] | 0.1 | 0.1 |
Temperature fluctuation at 25 ℃ and 60% relative humidity [± K] | 0.1 | 0.1 |
Humidity range [% relative humidity] | 10…80 | 10…80 |
Humidity fluctuation at 25 ℃ and 60% relative humidity | 1.5 ± relative humidity | 1.5 ± relative humidity |
Humidity fluctuation at 40 ℃ and 75% relative humidity | 1.5 ± relative humidity | 1.5 ± relative humidity |
The humidity recovery time after opening the door in 30 seconds is at 40 ℃ and 75% relative humidity [min] | 11 | 11 |
The humidity recovery time after opening the door in 30 seconds is at 25 ℃ and 60% relative humidity [min] | 5 | 5 |
Electric data | ||
Rated voltage [V] | 200…230 | 200…240 |
Power frequency [Hz] | 50/60 | 50/60 |
Rated power [kW] | 2.1 | 2.1 |
Equipment safety device [A] | 16 | 16 |
Phase (rated voltage) | 1~ | 1~ |
1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.