BINDER KBWF240 Growth Box
1、 Product Introduction:
1. Temperature range: 0 ℃ to 70 ℃
2. Temperature range with illumination: 10 ℃ to 60 ℃
3. Humidity range: 10% relative humidity to 80% relative humidity
4. 2 variable positioning lighting boxes, each with 5 fluorescent tubes
5 APT.line ™ Preheating chamber technology
6. Adjustable fan speed
7. Using capacitive humidity sensors and steam humidification for humidity regulation
8. Intuitive touch screen controller using interval programming and real-time programming
9. Internal data logger and open format measurement values can be read through USB
10. Equipment self-test is used for comprehensive status analysis
11. The sealed inner door is made of safety glass (ESG)
12. Preventing corrosion of glass through special TIMELESS coating
13. Display through LCD color monitor
14. Two sockets made of stainless steel
15. Access hole with silicone plug 30mm, left
16. Independently adjustable temperature safety device Class 3.1 (DIN 12880), equipped with optical and acoustic temperature alarms
17. Computer interface: Ethernet
18. Door heating
2、 Technical parameters:
PRODUCT MODEL | KBWF240-230V1 |
Choose a model | standard |
Item code | 9020-0336 |
measure | |
Internal volume [L] | 247 |
Net weight of equipment (unloaded) [kg] | 214 |
Maximum total load [kg] | 100 |
Maximum load per partition [kg] | 30 |
The dimensions of the casing do not include additional components and connectors | |
Net weight width [mm] | 925 |
Net weight at height [mm] | 1465 |
Depth net weight [mm] | 800 |
Wall distance from rear [mm] | 100 |
Wall to side distance [mm] | 100 |
Internal dimensions | |
Width [mm] | 650 |
Height [mm] | 785 |
Depth [mm] | 485 |
The number of doors | |
Inner door | 1 |
Outer door | 1 |
Data related to the environment | |
Energy consumption at 37 ℃ and 75% relative humidity [Wh/h] | 760 |
Sound pressure level [dB (A)] | 53 |
firmware | |
Number of partitions (hours/maximum) | 2/7 |
Number of Lighting Boxes (Standard/Maximum) | 2/2 |
Temperature performance data | |
Temperature range without lighting box [℃] | 0…70 |
Temperature range with 100% illumination [℃] | 10…60 |
Climate performance data | |
Temperature range without lighting box [℃] | 10…70 |
Temperature range with 100% illumination [℃] | 10…60 |
Humidity range without lighting box [% relative humidity] | 10…80 |
Humidity range with lighting box, with lighting [% relative humidity] | 10…75 |
Lighting data for each lighting box | |
Fluorescent lamp [W/m2]* | 24 |
Fluorescent lamp [lx]* | 9000 |
Fluora ® Cultivation lamp [W/m2]* |
23 |
Fluora ® Cultivation lamp [lx]* | 7500 |
Arabidopsis lamp [W/m2]* |
32 |
Arabidopsis lamp [lx]* | 11000 |
Electric data | |
Rated voltage [V] | 200…240 |
Power frequency [Hz] | 50 |
Rated power [kW] | 2.4 |
Equipment safety device [A] |
16 |
Phase (rated voltage) | 1~ |
1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes* The average value measured under the illumination box using a spherical sensor (± 10%) 12 cm at 25 ℃. The measurement unit is W/m2, which involves total radiation.