Shanghai Huanao Technology Co., Ltd
Home>Products>BINDER KMF240 Constant Temperature and Humidity Chamber
BINDER KMF240 Constant Temperature and Humidity Chamber
BINDER KMF240 Constant Temperature and Humidity Chamber
Product details

BINDER KMF240 Constant Temperature and Humidity Chamber

1、 Product Introduction:

1. Temperature range: -10 ℃ to 100 ℃

2. Larger humidity range: 10% relative humidity to 98% relative humidity

3 APT.lineTMPreheating chamber technology

4. Using capacitive humidity sensors and steam humidification for humidity regulation

5. The interior is entirely made of stainless steel

6. BINDER communication software APT-COM ™ 3 Basic versions

7. Intuitive touch screen controller using interval programming and real-time programming

8. Internal data logger and open format measurement values can be read through USB

9. Equipment self-test is used for comprehensive status analysis

10. The sealed inner door is made of safety glass (ESG)

11. Prevent corrosion of glass through a special TIMELESS coating.

12. 1 socket made of stainless steel

13. Access hole with silicone plug 30mm, left

14. Independently adjustable temperature safety device Class 3.1 (DIN 12880), equipped with optical and acoustic temperature alarms

15. Computer interface: Ethernet

16. Door heating

2、 Technical parameters:

Product model

KMF240-230V1

KMF240-240V1
Choose a model standard standard
Item code 9020-0343 9020-0344
measure
Internal volume [L] 247 247
Net weight of equipment (unloaded) [kg] 179 179
Maximum total load [kg] 100 100
Maximum load per partition [kg] 30 30
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 930 930
Net weight at height [mm] 1465 1465
Depth net weight [mm] 800 800
Wall to side distance [mm] 100 100
Wall distance from rear [mm] 100 100
Internal dimensions
Width [mm] 650 650
Height [mm] 785 785
Depth [mm] 485 485
The number of doors
Inner door 1 1
Outer door 1 1
Data related to the environment
Energy consumption at 85 ℃ and 85% relative humidity [Wh/h] 570 570
Sound pressure level [dB (A)] 52 52
firmware
Number of partitions (hours/maximum) 1/9 1/9
Temperature performance data
Temperature range [℃] -10…100 -10…100
The average heating rate is based on IEC 60068-3-5 [K/min] 0.8 0.8
The average cooling rate is based on IEC 60068-3-5 [K/min] 0.4 0.4
The maximum thermal compensation is at 25 ℃ [W] 200 200
Climate performance data
Temperature range [℃] 10…90 10…90
The temperature deviation depends on the set value [± K] 0.1…1 0.1…1
The temperature fluctuation depends on the set value [± K] 0.1…0.3 0.1…0.3
Humidity range [% relative humidity] 10…98 10…98
The humidity fluctuation depends on the set value ≤ 2 ± relative humidity ≤ 2 ± relative humidity
Condensation temperature range of condensate water [℃] 5…90 5…90
Electrical data
Rated voltage [V] 200…230 200…240
Power frequency [Hz] 50/60 50/60
Rated power [kW] 2.1 2.1
Equipment safety device [A] 16 16
Phase (rated voltage) 1~ 1~

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!