1、 Product Introduction:

1. Temperature range: ambient temperature plus 15 ℃ to 200 ℃

2 APT.lineTMPreheating chamber technology

3. Controller using interval programming and real-time programming

4. 2 aluminum expansion brackets

5. Inert gas interface

6. Anti impact safety glass panel with spring plates

7. Independent adjustable temperature safety device level 2 (DIN 12880) with optical alarm

8. Computer interface: RS 422

9. Two switches output 24V DC(Maximum 0.4 A)

2、 Technical parameters:

Product model VD023-230V1 VD023UL-120V1
Choose a model standard standard
Item code 9030-0029 9030-0035
measure
Internal volume [L] 23 23
Net weight of equipment (unloaded) [kg] 63 63
Maximum total load [kg] 35 35
Maximum load per partition [kg] 20 20
The dimensions of the casing do not include additional components and connectors
Net weight width [mm] 515 515
Net weight at height [mm] 665 665
Depth net weight [mm] 500 500
Wall to side distance [mm] 135 135
Wall distance from rear [mm] 100 100
Observation window width [mm] 250 250
Observation window height [mm] 207 207
Internal dimensions
Width [mm] 285 285
Height [mm] 285 285
Depth [mm] 295 295
The number of doors
Outer door 1 1
firmware
Number of partitions (hours/maximum) 2/4 2/4
Temperature performance data
The temperature range exceeds the indoor temperature by 15 ℃ to [℃] 200 200
Temperature deviation within 100 ℃ [± K] 1.5 1.5
Temperature fluctuation [± K] 0.1 0.1
Heating time to 100 ℃ [min] 65 65
Vacuum data
Allowable maximum vacuum [mbar] 0.01 0.01
Leakage rate [bar/h] 0.01 0.01
Electrical data
Rated voltage [V] 230 120
Power frequency [Hz] 50/60 60
Rated power [kW] 0.8 0.8
Equipment safety device [A] 10 12.5
Phase (rated voltage) 1~ 1~
Connecting components
Vacuum interface with small flange [DN mm] 16 16
Test hole with small flange [DN mm] 16 16
Inert gas interface with flow restrictor (RP) 3/8 3/8

1. All technical data is only applicable to standard specifications of unloaded equipment at an ambient temperature of 22 ± 3 ℃ and a power supply voltage fluctuation of ± 10%. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. We reserve the right to make technical changes.