test method |
visible light/UV Absorption Spectra
|
Fluorescence intensity(FI)Including FRET
|
Time-resolved fluorescence(TRF)Including TR-FRET
|
AlphaScreen ® |
polarization |
Glowing(FlashandGlow)Including BRET
|
detection mode | Top and bottom detection |
Endpoint and dynamic testing |
Continuous dual excitation luminescence detection |
Continuous dual emission detection |
Spectral scanning |
Pore scanning |
Read Mode | Top and bottom reading |
light source |
High intensity flashing xenon lampAlphaScreen for high-speed lasers ® / AlphaLISA ®
|
detector | Low noise photomultiplier tube and CCD spectrometer |
Wavelength selection | Linear Variable Filter (LVF) Monochromator:Separate excitation and emission using linearly variable bidirectional colors |
Filter: 4 excitation and 4 emission filters each |
LVF monochromator+filter: Ex 1, Em Other |
wavelength range | 240 - 750 nm or 240 - 900 nm for FI, FP, FRET, TRF, TR-FRET (filters) 320 - 850 nm for FI, FRET, TRF (monochromators) 240 - 750 nm for LUM (filters) 320 - 750 nm for LUM (monochromator) 220 - 1000 nm for ABS |
light path |
Top and bottom: Top and bottom: enclosed, with motor-driven mirrors and dichroic guidance to freely switch optical paths |
Z-axis adjustment | Automatic focus height adjustment (0.1 mm resolution) |
injector |
The biggest2A built-in sampler
|
compatible384Orifice plate, injection at measurement position
|
The injection volume of each detection hole can be adjusted(3…350μL)
|
Adjustable injection speed(100…420μL/s)
|
Each hole can be set as many as possible4Different injection volumes
|
Reagent recycling function |
incubator |
Room temperature+5℃ to45℃(65℃ optional)
|
Temperature Stability<0.2℃
|
Temperature uniformity<0.5℃
|
oscillating | Linear, track, and double track, custom time and speed |
Microplate type |
6…1536Orifice plate, custom plate,
|
Absorption spectrophotometer | wavelength range | 220nm…1000nm |
Wavelength Resolution | 1nm |
ODValue Range
| 0…4 |
accuracy |
2ODplace<0.1%
|
accuracy |
1ODplace<0.5% 2ODplace<0.8%
|
sensitivity | FI filter (top): 0.4 pM (< 8 amol/well Fluorescein, 384sv, 20 μL) FI filter (bottom): 1.0 pM (<50 amol/well Fluorescein, 384g, 50 μ L) FI monochromator (top): 0.5 pM (<10 amol/well Fluorescein, 384sv, 20 μ L) FI monochromator (top): 4.0 pM (<200 amol/well Fluorescein, 384g, 50 μ L) FP: 1.0 mP SD at 1 nM Fluorescein (384sv, 20 μL) TRF:0.1 pM (< 2 amol/well Europium, 384sv, 20 μL) LUM:0.75 pM (< 15 amol/well ATP, 384sv, 20 μL) AlphaScreen ® : 6 pM (< 100 amol/well P-Tyr-100, 384sv, 17 μL) ABS spectrophotometer: Wavelength range: 220 - 1000 nm Full wavelength scanning<1 s/well Optional wave width: 1, 2, 5, and 10 nm OD range: 0 - 4 OD Accuracy:< 1% at 2 OD Accuracy:< 0.5% at 1 OD and < 0.8% at 2 OD |
Reading board time |
Flyingmode
|
9s(96Orifice plate) 14s(384Orifice plate) 27s1536
|
software | Integrated fluorescence image library, multi-user control software, and MARS statistical analysis software, includingFDA 21 CFR Part 11 compliant
|
volume |
Width:45cm/Long:51cm/High:40cm
|
weight |
32kg
|
Stack IIAutomatic board feeder |
Zui can automatically inject samples50Block microporous plate
|
Continuous board entry mode |
Bar code reader |
Microplate incubator | Incubation and oscillation of microplates with 96 or more holes |
optical filter | The optimized fluorescence staining can be used for special analysis Filter can detect anything including UV to NIR Customer customized filter |
upgrade | It can be easily upgraded, such as detection mode and reagent injection |
| LOD = 3 x SD (20 blanks) / slope (6 pt std curve) AlphaScreen ® P-Tyr-100 assay kit, PerkinElmer, #6760620C Microplatets: white for LUM, AlphaScreen ®, TRF; black for FI, FP; clear for ABS 96 = 96-well microplates 384sv = 384-well small volume microplates 384g = 384-well glass bottom microplates 1536 = 1536-well microplates |