The full wavelength and full function enzyme-linked immunosorbent assay (ELISA) reader, one of the new members of the BMGLABTECH family, was launched
Product details

Purpose:
  • High throughput rapid testing in cellular and molecular biology, chemistry, immunology, physiology, pharmacology, and other fields,
  • Intermolecular interactions,
  • Report genes,
  • Enzyme activity and kinetic studies,
  • ATPContent determination,
  • Cell proliferation, cytotoxicity,PCRQuantitative,
  • Membrane potential, ion channels, signal transduction, etc.
Main features:
  • Can be used for full wavelength fluorescence intensity, time-resolved fluorescence, UV visible absorption lightContinuous wavelength scanningDetection of chemiluminescence and bioluminescence;
  • Fluorescence polarization test
  • Alyha test
  • Top and bottom two reading modes
  • Two sets of samplers can be equipped as needed, with a pipetting range of5~350 μl0.5μLIncremental, each hole can add different volumes, and each hole can add up to4Secondary sample
  • 45incubationselectable60℃, and can be placed in a cold room for low-temperature detection
  • Slow and Fast DynamicsThe fastest speed can reach every second50Secondary test reading
  • Can be doneBRET / FRETtest
  • It can simultaneously perform fluorescence and luminescence dual emission optical reading, and dual excitation detection is currently the fastest among similar brandsFRETperhapsBRETFluorescence intensity measurement analyzer


    CLARIOstar is a modular, full wavelength, and fully functional enzyme-linked immunosorbent assay (ELISA) reader that combines advanced LVF monochromator, high-sensitivity filter technology, and ultrafast spectrophotometer technology. It has 8 different detection modes, including: FI fluorescence intensity, FRET, Fluorescence polarization luminescence, BRET, UV/Vis absorption, time-resolved fluorescence, TR-FRET, And AlphaScreen ® / AphaLISA ®.

characteristic
Full spectrum UV/visible absorbance (220 to 1000nm) and BMG's unique ultrafast spectrometer (<1 second/well); AlphaScreen and AlphaLISA detection have high-energy lasers, kinetics, and cell analysis that can accommodate reagent injection. The integrated fluorescence library makes it easier to conduct experimental development.
Advanced LVF monochromator and filter selection system
*The measurement and development of fluorescence detection methods, CLARIOstar has an advanced monochromator flexibility that can be combined with higher sensitivity filters. Advanced monochromators with continuously adjustable wavelengths (320 to 850nm) and bandwidths (8 to 100nm) for excitation and emission,
Compared to traditional monochromatorsSignificantly enhanced performance.

The technical parameters are as follows:
test method
visible light/UV Absorption Spectra
Fluorescence intensity(FI)Including FRET
Time-resolved fluorescence(TRF)Including TR-FRET
AlphaScreen ®
polarization
Glowing(FlashandGlow)Including BRET
detection mode
Top and bottom detection
Endpoint and dynamic testing
Continuous dual excitation luminescence detection
Continuous dual emission detection
Spectral scanning
Pore scanning
Read Mode
Top and bottom reading
light source
High intensity flashing xenon lampAlphaScreen for high-speed lasers ® / AlphaLISA ®
detector
Low noise photomultiplier tube and CCD spectrometer
Wavelength selection
Linear Variable Filter (LVF) Monochromator:Separate excitation and emission using linearly variable bidirectional colors
Filter: 4 excitation and 4 emission filters each
LVF monochromator+filter: Ex 1, Em Other
wavelength range
240 - 750 nm or 240 - 900 nm for FI, FP, FRET, TRF, TR-FRET (filters)
320 - 850 nm for FI, FRET, TRF (monochromators)
240 - 750 nm for LUM (filters)
320 - 750 nm for LUM (monochromator)
220 - 1000 nm for ABS
light path
Top and bottom:
Top and bottom: enclosed, with motor-driven mirrors and dichroic guidance to freely switch optical paths
Z-axis adjustment
Automatic focus height adjustment (0.1 mm resolution)
injector
The biggest2A built-in sampler
compatible384Orifice plate, injection at measurement position
The injection volume of each detection hole can be adjusted(3…350μL
Adjustable injection speed(100…420μL/s
Each hole can be set as many as possible4Different injection volumes
Reagent recycling function
incubator
Room temperature+5℃ to45℃(65℃ optional)
Temperature Stability<0.2℃
Temperature uniformity<0.5℃
oscillating
Linear, track, and double track, custom time and speed
Microplate type
6…1536Orifice plate, custom plate
Absorption spectrophotometer
wavelength range
220nm…1000nm
Wavelength Resolution
1nm
ODValue Range
0…4
accuracy
2ODplace<0.1%
accuracy
1ODplace<0.5%
2OD
place<0.8%
sensitivity
FI filter (top): 0.4 pM (< 8 amol/well Fluorescein, 384sv, 20 μL)
FI filter (bottom): 1.0 pM (<50 amol/well Fluorescein, 384g, 50 μ L)
FI monochromator (top): 0.5 pM (<10 amol/well Fluorescein, 384sv, 20 μ L)
FI monochromator (top): 4.0 pM (<200 amol/well Fluorescein, 384g, 50 μ L)
FP: 1.0 mP SD at 1 nM Fluorescein (384sv, 20 μL)
TRF:0.1 pM (< 2 amol/well Europium, 384sv, 20 μL)
LUM:0.75 pM (< 15 amol/well ATP, 384sv, 20 μL)
AlphaScreen ® : 6 pM (< 100 amol/well P-Tyr-100, 384sv, 17 μL)
ABS spectrophotometer:
Wavelength range: 220 - 1000 nm
Full wavelength scanning<1 s/well
Optional wave width: 1, 2, 5, and 10 nm
OD range: 0 - 4 OD
Accuracy:< 1% at 2 OD
Accuracy:< 0.5% at 1 OD and < 0.8% at 2 OD
Reading board time
Flyingmode
9s96Orifice plate)
14s
384Orifice plate) 27s1536
software Integrated fluorescence image library, multi-user control software, and MARS statistical analysis software, includingFDA 21 CFR Part 11 compliant
volume
Width:45cm/Long:51cm/High:40cm
weight
32kg
Stack IIAutomatic board feeder
Zui can automatically inject samples50Block microporous plate
Continuous board entry mode
Bar code reader
Microplate incubator
Incubation and oscillation of microplates with 96 or more holes
optical filter
The optimized fluorescence staining can be used for special analysis
Filter can detect anything including UV to NIR
Customer customized filter
upgrade
It can be easily upgraded, such as detection mode and reagent injection
LOD = 3 x SD (20 blanks) / slope (6 pt std curve)
AlphaScreen ® P-Tyr-100 assay kit, PerkinElmer, #6760620C
Microplatets: white for LUM, AlphaScreen ®, TRF; black for FI, FP; clear for ABS
96 = 96-well microplates
384sv = 384-well small volume microplates
384g = 384-well glass bottom microplates
1536 = 1536-well microplates
Online inquiry