productpurpose
Scope of detection (object)
※ Aromatic compounds: a series of compounds containing benzene rings, such as benzene, toluene, naphthalene
※ Ketones and aldehydes: containingC=OCompounds with bonds, such as acetone
※ Ammonia and amines: containingNHydrocarbons such as dimethylamine
※ Halogenated hydrocarbons: Thiohydrocarbons
※ Unsaturated hydrocarbons: olefins, etc
※ alcohols
※ Inorganic gases without carbon: ammonia, arsenic, selenium, bromine and iodine, etc.
FEATURES
Photoionization detectorPIDYes, that's right30Multiple volatile organic compounds(VOCs)Benzene, toluene, and xylene have sensitive responses;
Suitable for various industrial environmentsVOCGas detection;
Automatic calibration can be achieved with isobutene;
The range switch can select multiple different ranges;
Fast response speed and high sensitivity;
Large touchscreen display, sound and light alarm, low/tall2An alarm point that can be set;
Built in sampling pump, sampling tube can be remotely sampled;
Built in condensation and water removal device;
Built in multi-stage particulate matter filtration device;
Intelligent zero point and range calibration function:BY-VOC-600PAdopting unique intelligent zero point tracking technology to obtain very accurate zero points for detectingppbofVOCGas.
Flexible unit conversion: for different factoriesVOCThe gas sources are different, so theirppmchangemg/m3The value is not a fixed value. Traditional instruments use isobutene2.5This is only suitable for detecting benzene derivatives in environments with high molecular weight, such as ethyl acetate,2.5Doubling is not enough,BY-VOC-600Pofppmchangemg/m3The relationship between units can be set by users themselves.
Technical Parameter
range |
0-100ppm-1000ppm |
Indication error |
±2%F.S. /day |
response time |
60second |
Working environment humidity |
(10%~95%)RHNo condensation |
Distance |
1000rice |
weight |
±5%F.S. /day |
Allowable error |
Fixed continuous measurement |
way of working |
-10℃~50℃(optional-20℃~50℃) |
Ambient Temperature |
two-wire4-20mAstandard output |
Analog signal output |
1300(High) ×800(Width) ×500(Deep)mm |
External dimensions |
±5%F.S. /day |