VIP member
BYG400-NX Multi in One Gas Environment Online Detector
BYG400-NX Multi in One Gas Environment Online Detector Introduction BYG400-NX Series Multi in One Gas Environment Online Detector is a comprehensive a
Product details
2、 Application of Multi in One Gas Environment Online Detector Equipment
The BYG400-NX series multi in one gas environment online detector is suitable for embedded matching and system integration of air environment monitoring equipment; Places such as smart office building environmental monitoring systems, smart home environmental monitoring systems, school and hospital environmental monitoring systems, hotel environmental monitoring systems, public environmental monitoring systems, online monitoring of toxic and harmful gases in factories, and environmental detection in ship cabins and stations.
3、 Characteristics of Multi in One Gas Environment Online Detector
1. Stable and reliable communication, wide range power supply DC12-24V;
2. Complete anti reverse, overvoltage, overcurrent, and inter line protection capabilities;
3. Carefully designed circuit software and hardware, with low failure rate and short stability time;
4. Original imported sensors and professional grade signal processing chips ensure the accuracy of sensor data;
5. The measurable environmental parameters cover a wide range and can meet various detection environment requirements;
6. RS485 industrial grade signal output, with a long transmission distance of over 1 kilometer;
7. Aerodynamic breathable through-hole, built-in blower to accelerate air flow, real-time sampling, stable and reliable;
8. Measurement parameters can be customized according to customer requirements, with flexible and convenient parameter combinations.
4、 Electrical characteristics of multi in one gas environment online detector
4、 Electrical characteristics of multi in one gas environment online detector
operation parameters | work environment | -20~60℃; 0-95% RH (no condensation) |
Environment | -40~70℃; 0-100% RH (no condensation) | |
power input | DC 12~24V; Equipped with a power adapter that can supply 220V power | |
current consumption | The average value is 250mA, and the peak value is 500mA | |
signal output | RS485 modbus RTU、 Ethernet WIFI、GPRS、 433 optional | |
Installation method | Wall mounted (fixed with bottom mounting plate) | |
Shell material | Cast Aluminium material | |
protection grade | IP65 | |
size | 300× with connector; 270× 100mm |
5、 Technical parameters of multi in one gas environment online detector
BYG400-NX series | parameter selection (If you need to order parameters, please type "radic") |
||||
Detection parameters | principle | range | resolution | accuracy | |
noise | Electrified capacitor type | 30-130dB | 0.1dB | ± 1.5dB | |
PM2.5 | Laser optics | 0 ~ 1000ug/m³ | 1ug/m³ | ± 10% F.S | |
PM10 | Laser optics | 0 ~ 2000ug/m³ | 1ug/m³ | ± 10% F.S | |
CO | electrochemical principle | 0 ~ 500ppm | 1ppm | ﹤± 3% F. S | |
TVOC | electrochemical principle | 0 ~ 10ppm | 0.01ppm | ﹤± 5% | |
SO2 | electrochemical principle | 0 ~ 20ppm | 0.01ppm | ﹤± 5% | |
NO2 | electrochemical principle | 0 ~ 100ppm | 0.01ppm | ﹤± 5% | |
H2S | electrochemical principle | 0 ~ 20ppm | 0.01ppm | ﹤± 5% | |
O3 | electrochemical principle | 0 ~20ppm | 0.01ppm | ﹤± 5% | |
…& hellip; | |||||
*When placing an order, it is necessary to specify the required parameters and determine the order selection. A maximum of five toxic and harmful gas parameters can be selected. |
6、 Installation of Multi in One Gas Environment Online Detector
1. First, fix the installation disk on the wall
2. After connecting the equipment, fix it on the installation disk.
3. Do not connect the transmitter to a voltage higher than 24VDC. To prevent excessive voltage from burning out the sensor.
4. Install the transmitter at the location that needs to be tested, away from the heating element or steam source, and prevent direct sunlight.
5. When wiring the circuit, connect the wires to the terminal blocks to ensure that the wiring is correct and secure.
Online inquiry