Beidou Star Instrument Portable Gas Liquefied Gas Calorific Value Analyzer
The portable gas liquefied gas calorific value analyzer pGas2000-FGA5s is mainly used for rapid analysis and detection of the composition and calorifi
Product details

Beidou Star Instrument Portable Gas Liquefied Gas Calorific Value AnalyzerInstrument features:

Built in microcontroller microcomputer

Quickly detect parameters and temperature values, and perform temperature correction and cross correction

24 sets of data records, can be set to automatic or manual recording

RS232/485 duplex interface, capable of online sampling with microcomputers

Inert gas software zeroing, standard sample or substitute calibration

All operation keyboard settings, window prompts

Instrument function:

Beidou Star Instrument Portable Gas Liquefied Gas Calorific Value AnalyzerFunction:

On site LCD 4 × 16 character rotating display of multiple environmental parameters

Over limit alarm, alarm limit can be set

RS232/RS485 communication interface supports serial communication and can be connected to a computer

Comes with a serial micro printer

100 sets of data records. Readable, output or print

Optional pump sampling or depressurization sampling

Can enhance gas filter columns or other filters

Users can also calibrate or calibrate themselves

Calculation of calorific value through whole component analysis

Technical specifications of pGas200 gas calorific value meter:

BD4 host testing ADC resolution: 0.025%FS

BD4 host test repeatability accuracy: 0.05%FS

Electrochemical probe accuracy: ± 1-2% reading (general)

Long term stability:+/-10%/year (generally)

Analyzer response time:< 10ms;

Probe response time:< 1min;

Instrument usage environment: Temperature: -10 ℃ to 60 ℃; Humidity: 10% to 90% R (no condensation)

Instrument storage environment: temperature: 0 ℃~50 ℃; Humidity: 10% to 80% R (no condensation)

Electrochemical probe direct sampling: temperature: 0-40 ℃; Pressure:< 1.1 kgf/cm2

Power supply: 6V rechargeable battery

Continuous usage time:> 24 hours per charge; The battery should be stored for one week.

Electrical function and performance:

Please refer to the introduction of BD4/BD5 intelligent transmitters/controllers

Chassis packaging: NEMA 1/IP10;

Chassis size: 700*360*250

Instrument quality assurance: 1 year

Technical specifications of pGas2000-FGA-5s portable liquefied gas gas analyzer:

Professional analysis system

Professional analysis system

repeatability

accuracy

stability

technology

notes


C/C2/C3/C4

0-50%

<± 1% FS or ± 1% Rel, whichever is greater;

<± 1% abs @ standard gas

<0.05% in 20 seconds, constant temperature< 2% per year

IRS

Infrared Spectral Analysis of CH4 and CnHm


H2

0-100%

<1%R

<±2%R

<2%/year

TCD

heat conductance


CO

0-100%

<± 1.5% FS or ± 1% Rel, whichever is greater;

<± 1.5% abs @ standard gas

<10%/year

NIR

Non dispersive infrared


CO2

0-20%

<± 1% FS or ± 1% Rel, whichever is greater;

<± 1% abs @ standard gas

<2%/year

NIR

Non dispersive infrared


H2O

100ppm-3%

<1%R

<1.5%

<1.5%/year

SMC

semiconductor


Calorific value range

0-40MJ/NM3


<1.5%



count


Usage of portable gas calorimeter:

At the sampling port, first use a pressure reducing valve to reduce the pressure to below 0.1kgf/cm2, and then use the instrument's fine-tuning to adjust it to around 10Pa for testing and analysis. This process should take 3-5 minutes to complete.

A simple and practical method that is not standardized enough is to take a plastic bag, put the gas from the pipeline into the plastic bag, maintain the minimum flow rate, insert the instrument sample tube into the plastic bag, and start the test. It is necessary to ensure that there are no ignition hazards in the environment before operation.

Instrument usage and maintenance:

If conditions permit, portable analyzers can generally be calibrated once a month, with a maximum of once a year; Before each use, an air test can be conducted. If there are obvious erroneous values, air zeroing can be performed to greatly overcome sensor drift;

The instrument is divided into three modes: natural gas, liquefied gas, and other organic fuels, each with its own calibration table. When analyzing a certain gas, use the keyboard to call up the response mode for testing.