Beidou Star Odor Pollutant Detector
Beidou Star Odor Pollutant Detector, Beidou Star Instrument Odor Detector is mainly used for the emission of odorous gases from sewage treatment plant
Product details

PAir2000-EFF portable environmental atmospheric odor pollutant detector

[Instrument Introduction]

Beidou Star Odor Pollutant DetectorThe pAir2000-EFF portable ambient air odor pollutant detector combines the wisdom of several generations of Beidou experts from the Chinese Academy of Sciences over the past three decades, integrates all practical and reliable gas sensors in the world by studying different gas detection and sensing technologies, and establishes a multi application environment suitable for electrochemical method, gas sensing method, infrared method, catalytic combustion method, semiconductor method, PID photoion method, etc. By optimizing different gas combinations and interference factors, it can also meet the on-site, high-resolution gas detection combination mode. After more than 20 years of continuous exploration, testing and technology upgrading, it has formed six product series for odor gas emission detection, which are targeted for gas detection in various complex environments.

The pAir2000-EFF portable environmental atmospheric odor pollutant detector is designed specifically for detecting odor pollutants in the environment, in accordance with the requirements of the national standard GB14554-93 "Emission Standards for Odor Pollutants" of the People's Republic of China. The standard includes 4-23 built-in basic gas detection sensors, each of which can detect specific odor gases. The series of 6 models of instruments not only meet the gas pollution detection requirements of the national standard, but also meet the requirements of the "Local Pollutant Emission Standards" recently issued by local governments and the characteristics of industrial gas pollution source emissions.

The design concept of the pAir2000-EFF portable environmental atmospheric odor pollutant detector is to establish a gas detection combination mode that optimizes different gas combinations and interference factors for various on-site environments, meets on-site detection, and has high resolution. After more than 20 years of continuous exploration, testing, and technological upgrades, it has formed six product series, among which the pAir2000-EF-A type is a universal odor pollutant detector; The pAir2000-EFF-B type is a multi parameter gas detector in this series that meets the detection requirements of the national standard "Odor Pollutant Emission Standards". The pAir2000-EFF-C is designed specifically for industrial production, sewage treatment plants, biopharmaceuticals, and chemical pollution source emissions, including detection parameters for methane and chlorine, to meet the characteristics and requirements of industrial gas emissions;

*The application of module processing intelligent system and cross interference gas neural network correction mode analysis technology to achieve real-time correction compensation, obtain reliable and accurate test results, and provide reliable guarantee for the resolution of the instrument. The multi-functional integrated design of one machine also saves financial and manpower resources for society, and improves detection efficiency.

The pAir2000-EFF portable environmental atmospheric odor pollutant detector is widely used in industries such as petrochemicals, chemicals, wood, paper, environmental protection agencies, and environmental colleges. Its speed, convenience, reliability, and durability have been rated as competitive domestic gas detectors by users.

Beidou Star Odor Pollutant DetectorTechnical advantages

  • The standard built-in basic gas detection sensors range from 4 to 23, each sensor responding to different gases. Meet the requirements of national standards and local "Emission Standards for Odor Pollutants".

  • Conventional setup includes 6 channels for gas and 1 channel for temperature testing and 1 channel for humidity testing.

  • Support DKA (dual standard method) standard sample or substitute calibration, as well as single point pure inert gas calibration.

  • Providing cross interference gas neural network correction mode analysis technology has solved the problem of cross interference in gas detection.

  • The multi-functional integrated design of one machine saves users financial and human resources, and improves detection efficiency.

Beidou Star Odor Detector Function

  • The gas sensor adopts sensing technologies such as electrochemical method, gas sensing method, infrared method, catalytic combustion method, semiconductor method, PID photoionization method, etc.

  • Gas detection parameters can be selected according to the actual situation, and multiple gases can be detected simultaneously on one instrument.

  • Equipped with printing, capable of completing on-site and laboratory testing needs.

  • Pump sampling and sampling.

  • The sensor operates in real-time and continuously detects the working mode.

  • Power undervoltage and power failure alarm.

  • Quickly detect parameters and temperature values, and perform temperature correction and cross correction.

  • Inert gas software zeroing, standard sample or substitute calibration.

  • All operation keyboard settings, window prompts.

  • On site LCD 4 × 16 character rotating display of multiple environmental parameters.

  • The RS232/RS485 communication interface supports serial communication and can be connected to a computer.

  • Users can also calibrate or calibrate themselves.


Odor detector [Technical parameters]:

  • Response time:< 10ms

  • Long term stability: ± 10%/year (generally)

  • Host resolution: 0.1% FS

  • Sensor accuracy: ± 1-2% reading (general)

  • Probe response time:< 3mins(T90)

  • Instrument usage environment: Temperature: -10 ℃~60 ℃; Humidity: 10%~90% R (no condensation)

  • Instrument storage environment: temperature: 0 ℃~4 ℃; Humidity: 10%~80% R (no condensation)

  • Probe sampling requirements: temperature: 0~40 ℃; Pressure:< 1.1 kgf/cm2

  • Instrument power supply: 12V rechargeable battery

  • Instrument size: 400 × 300 × 200mm

  • Instrument weight: 4.5Kg


Typical Applications of Odor Analyzer

  • PAir2000-EFF-A configuration parameters (applicable for general odor pollutant detection)

  • PAir2000-EFF-B configuration parameters (applicable to the requirements of the national standard GB14554-93 "Emission Standards for Odor Pollutants")

  • PAir2000-EFF-C configuration parameters (applicable to industrial production, sewage treatment plants, biopharmaceuticals, and chemical pollution source emissions)

  • PAir2000-EFF-D configuration parameters (applicable to solid waste landfill pollution source emissions)

  • PAir2000-EFF-E configuration parameters (applicable for air pollutant emission gas detection)

  • PAir2000-EFF-F configuration parameters (applicable to expansion instruments, with the option to add gas)


PAir2000-EFF-A configuration parameters (applicable for general odor pollutant detection)

No

Main measured gas

Gas parameters

detection range

1

Ammonia and low molecular weight amines

NH3

0.5-50/200ppm

2

Hydrogen sulfide and sulfide

H2S

0.3-100mg/m3

3

Thiols and thioethers

CH3SH

0.5-50mg/Nm3

4

Volatile Organic Compounds

EVOC

0.1-100ppm

5

Odor concentration

ODU

0-500 dimensionless


PAir2000-EFF-B configuration parameters (applicable to the requirements of the national standard GB14554-93 "Emission Standards for Odor Pollutants")

Serial Number

Main measured gas

range

Zui low lower limit

1

Ammonia NH3

0~100 ppm

0.1ppm

2

Hydrogen sulfide H2S

0~100 ppm

0.1ppm

3

Styrene C8H8

3.0~19 ppm

0.02ppm

4

Sanjia amine (CH3) 3N

0~5 ppm

0.005ppm

5

Methyl mercaptan CH3SH

0~14 ppm

0.01ppm

6

Sulfide (CH3) 2S

0~300ppm

0.3ppm

7

Carbon disulfide CS2

0~100 ppm

0.1ppm

8

Dimethyl disulfide (CH3) 2S2

0.03~30ppm

0.03ppm

9

Organic volatile gas TVOC

0-200ppm

0.2ppm

10

Odor concentration

0-10000

10


PAir2000-EFF-C configuration parameters (applicable to pollution source emissions from sewage treatment plants, biopharmaceuticals, and chemical plants)

Serial Number

gas

Main measured gas

sensor

Range of measurement

1

ammonia

NH3

electrochemistry

0.75-75 mg/m3

2

hydrogen sulfide

H2S

electrochemistry

0.15-75/750 mg/m3

3

Chlorine Qi

CL2

electrochemistry

0.05-5/50ppm

4

methane

CH4

infrared

0-4%;

5

Odor concentration

ODU


0-500 dimensionless


PAir2000-EFF-D configuration parameters (applicable to solid waste landfill pollution source emissions)

No.

Main measured gas

Gas parameters

detection range

1

Ammonia and low molecular weight amines

NH3

0.5-50/200ppm

2

Hydrogen sulfide and sulfide

H2S

0.3-100mg/m3

3

Thiols and thioethers

CH3SH

0.5-50mg/Nm3

4

hydrogen

H2

0-1%

5

oxygen

O2

0-25%

6

carbon dioxide

CO2

0-50%;

55-100%;

7

carbon monoxide

CO

0-2000ppm

8

Organic gas

VOC

0-5% 5-100%

9

Non methane organic gas

NMOCs


10

Chlorofluorocarbons

CFC

0-3000ppm

11

Other organic toxic gases

EVOC

0.1-100ppm

12

Other toxic gases

C6H5CH3

0.1-30ppm

13

Odor concentration

ODU

10-10000


PAir2000-EFF-E configuration parameters (applicable for air pollutant emission gas detection)

No

Gas name

Gas parameters

detection range

1

temperature

T

-40-100℃

2

humidity

RH

0-99%RH

3

velocity of flow

Air velocity

0.01-20m/s

4

sulfur dioxide

SO2

0.025-10/100ppm

5

hydrogen sulfide

H2S

0.1-50/500ppm

6

carbon monoxide

CO

0.1-500/1000ppm

7

carbon dioxide

CO2

2-2000ppm

8

nitrogen dioxide

NO2

0.02-10/100ppm

9

nitric oxide

NO

0.5-100/300ppm

11

ammonia

NH3

1-100ppm

12

Volatile organic gases

VOCs

0.1-100ppm

13

ozone

O3

0.02-2/5ppm

14

Total suspended particulate matter

TSP

0.01-2/20mg/M3

14

PM10

PM10

0.01-2/20mg/M3

14

PM2.5

PM2.5

0.01-100mg/M3

15

hydrogen fluoride

HF

0.25-10ppm

16

benzopyrene

B[a]P

0.015-1.5mg/NM3

17

formaldehyde

CH2O

0.05-10.0ppm

18

benzene

C6H6

0.03-30ppm

19

toluene

C7H8

0.04-50ppm

20

xylene

C8H10

0.04-50ppm

21

radon

Rn

0-1000Bq/NM3

22

Total bacterial count

TNB

0-25000CFU/NM3

23

lead

Pb


24

noise

Noise

35-130dB

25

methanol

CH3OH

0.05-50ppm

26

Chlorine Qi

Cl2

0.05-5ppm

27

Odor concentration

ODU

10-10000


PAir2000-EFF-F configuration parameters (applicable to expansion instruments, with the option to add gas)

No

Gas name

Gas parameters

1

sulfur dioxide

SO2,

2

hydrogen sulfide

H2S,

3

nitrogen dioxide

NO2,

4

nitrogen dioxide

NO2,

5

nitric oxide

NO,

6

nitric oxide

NO,

7

carbon monoxide

CO,

8

carbon dioxide

CO2

9

air quality index

AQI

10

Volatile organic gases

TVOC

11

ozone

O3,

12

ammonia

NH3,

13

ammonia

NH3,

14

Fluoride ion

F-

15

fluorine gas

F2

16

Chloride ion

Cl-

17

Chlorine Qi

Cl2

18

SCN

CN-

19

formaldehyde

CH2O

20

carbon disulfide

CS2

21

methyl mercaptan

CH3SH

22

methyl mercaptan

CH3SH

23

Disulfide dimethyl

C2H6S2


Typical users:

PetroChina Jinxi Petrochemical Plant, Ningbo Asia Pulp and Paper Industry, Keno (Beijing) Wood Industry Co., Ltd., Jinhu Tire (Tianjin) Co., Ltd

China University of Aeronautics and Astronautics, Yaobai Special Cement Group of China Western Cement Co., Ltd., Dalian University for Nationalities, Wuhu Solid Waste Treatment Project

Manufacturer, quotation, Beijing Beidouxing Industrial Chemistry Research Institute



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!