Beijing volatile organic solvent concentration alarmCPT2312-ADE22T
Name |
Volatile organic solvent concentration alarm |
|
|||||
Transmitter Specification and model |
CPT2312-ADE22T |
||||||
monitor Specification and model |
XM3.5-1 |
||||||
|
|
||||||
Probe requirements |
model:
|
convention |
unconventional |
|
|
|
|
Test conditions |
Range: 50-5000ppm |
Tested substance:
|
Temperature:
|
Pressure:
|
|
||
Transmitter Output |
4-20mA |
0-20mA√ |
|
|
|
||
Transmitter On site power supply |
24V |
12V |
|
|
|
||
Secondary table Output |
4-20mA 0-20mA |
RS485 RS232 |
Switching output (requires linkage with fire protection system)√
|
||||
Secondary table On site power supply |
220V√ |
110V |
24V |
12V |
|
||
Wiring |
two-wire |
Three-wire |
four-wire system
|
|
|
|
|
Explosion proof requirements |
Intrinsically safe type |
|
|
|
|
||
Installation method |
Indoor wall mounted: |
The Conduit: |
|
|
|
||
Cable length/meter |
standard |
||||||
Alarm point setting |
|
Beijing volatile organic solvent concentration alarmCPT2312-ADE22T, CPT2000 series gas alarm (transmitter)
- Product Introduction:
The CPT2000 series gas detection alarm adopts catalytic combustion, electrochemical, and semiconductor sensors with * level. The internal circuit is designed with a single-chip microcomputer, LED digital display, sound and light alarms, and is powered by the power grid. This alarm device has the advantages of long lifespan, good stability, strong anti-interference ability, small size, light weight, and simple and convenient installation. Simultaneously equipped with digital display and sound and light alarm functions. It can continuously detect the gas concentration in the surrounding environment, and once the gas concentration reaches the preset alarm value, it will emit sound and light alarms.
IITechnical performance indicators: (See the attached table for different gas indicators))
1. Detection error: ≤ ±5%(F.S);≤ ± 0.5% (oxygen)
2. Temperature display range: -20 ℃ to+40 ℃
3. Alarm method: The buzzer emits a sharp sound and has an alarm light on
4. Power supply voltage: 220V, 50HZ
5. Working hours: Can work continuously for 24 hours without interruption
6. Sensor lifespan: guaranteed for one year (if the sensor is damaged within one year, our company is responsible for replacing it free of charge, except for damage caused by improper use by the user)
7. Explosion proof mark: ExiaIICT5 Gb
8. Environmental conditions for use: temperature -20 ℃ to+40 ℃, humidity ≤ 85% RH, atmospheric pressure 86-106KPa
9. Weight: ≤ 5kg
, Gas Monitoring Alarm, Gas Alarm, Beijing Beidouxing Industrial Chemistry Research Institute, -805