1Connection data collection |
![]() |
||||||||
Digital control connection: 5D&6D terminals; Power control connection: 12V&DGND terminals; Simulation control connection: *,+, -, #, each CEM20 module is connected to an independent simulation channel; Maximum distance between data acquisition and module: 100m; |
|||||||||
2. Multi channel converter | |||||||||
Type: Relay multiplexer; Maximum input voltage: 30Vdc; Maximum sampling rate: 12Hz; |
|||||||||
3System Information | |||||||||
LED indicator light: indicating sampling function; Module address selection: 4-digit dip switch; |
|||||||||
4Power supply | |||||||||
Recommended power supply: Data collector 12V power output; Variable power supply: external 12Vdc power supply, power supply variation ± 5%; Sampling power consumption: 0.36W (12Vdc 30mA); Non working state: When not samplingCEM20The module will automatically shut down and restart during sampling |
|||||||||
5. Size and environment | |||||||||