COD-60A Oxygen Consumption/Permanganate Index Rapid Analyzer - Huilong Huanke 010-59483667
Keywords: COD-60A oxygen consumption/permanganate index rapid analyzer, oxygen consumption/permanganate index rapid analyzer, American Hash, Huilong Huanke
COD-60A oxygen consumption/permanganate index rapid analyzer introduction:
The COD-60A oxygen consumption/permanganate index rapid analyzer adopts acidic (alkaline) potassium permanganate titration method and a heating/titration integrated measurement system. Through unique control methods, the digestion and titration determination processes have been fully automated. Easy to operate, convenient and fast. This instrument can be widely used for rapid determination of oxygen consumption/permanganate index in drinking water, surface water, groundwater, seawater, industrial water and other fields. COD-60A Oxygen Consumption/Permanganate Index Rapid Tester Product Features:
The titration method is reliable and the data is accurate;
Rapid measurement;
Multi range, directly read COD value;
Easy to operate;
Can be converted into standard method measurement values;
Automatic standard program control to reduce operational errors;
Diverse maintenance/inspection functions;
Data storage function (100 sets), built-in printer and clock
COD-60A oxygen consumption/permanganate index rapid measuring instrument technical indicators:
Determination method: Acidic (or alkaline) potassium permanganate method
Determination principle Coulombic titration method (endpoint detection is oxidation-reduction potential method)
Titration temperature 65 ℃
Display graphic LCD display during measurement: real-time display of sequence status, measurement solution temperature, titration curve and other error messages: titration cannot be performed, blank error, outside effective range
Measurement range standard: 10~800s adjustable
arbitrarily: 0~(10~2000mg/L can be set)
Dilution is required for concentrations above 0-20mg/L
Reproducibility ± 2% F S
Resolution 0.01mg/L
Program control from oxidation to titration, fully automated measurement and processing (acid method only)
Calculation function, regression formula conversion function
Statistical calculation (average value)
Automatic input of blank values (or manual input)
Data storage of 100 data (measurement time, sample number, results)
Built in printer
Output RS-232C, External printer
Power supply AC220V 50/60Hz
Weight: Approximately 3.5kg
The digestion time can be adjusted from 10 to 800 seconds
COD-60A oxygen consumption/permanganate index rapid measuring instrument, oxygen consumption/permanganate index rapid measuring instrument, American Hash, Huilong Environmental Science
24-hour sales hotline: 010-59483667