The DR1010 COD analyzer from Hash Company is a photometric COD analyzer developed specifically for Chinese users based on their water quality, usage habits, and regulatory requirements. Meets the requirements of HJ/T 399-2007 "Determination of Chemical Oxygen Demand in Water Quality - Rapid Digestion Spectrometric Method" for COD determination in environmental protection systems using rapid digestion spectrophotometry, and supports the classic 2-hour digestion COD determination method of Hash Company. The instrument has a built-in standard COD test curve and supports users to create their own curves. The DR1010 COD tester adheres to Hash Company's rigorous product development style and features compliance with standards, high precision, and high flexibility in use.
COD analyzer DR1010Performance:
The experimental results are displayed in terms of concentration, absorbance, or transmittance. Automatically select the wavelength when selecting the corresponding testing program. Data storage and retrieval of data records can be carried out in the laboratory or on-site. The functions of reagent blank correction and standard adjustment can be utilized to compensate for the differences between batches of reagents. During the testing process, there is an icon prompt function. The RS232 port allows the measuring instrument to connect to an external printer or computer. You can input user-defined measurement methods or new hash measurement methods. Display error signals for troubleshooting program or instrument malfunctions. |
Hash DR1010 technical parameters:
Wavelength range: 420nm and 610nm |
Battery power supply: 190~240VAC 50Hz input, Suitable for 6VDC output power supply |
DR1010 single parameter COD analyzer panel functions:
Choose a high range two-hour digestion method. When the "#" graphic is displayed below the screen, it can also be used as the number key 7. |
|
Choose a low range two-hour digestion method. When the "#" graphic is displayed below the screen, it can also be used as the number key 4. |
|
Choose a high range 15 minute digestion method. When the "#" graphic is displayed below the screen, it can also be used as the number key 1. |
|
Choose the low range 15 minute digestion method. When the "#" graphic is displayed below the screen, it can also be used as the number key 1. When the "#" graphic is displayed below the screen, pressing the CE key will clear the most recent operation (deleting the entire input character, not just the digits after the last digit). |
|
Print the currently displayed data. Print the call data under the historical data menu. When the "#" graphic is displayed below the screen, it can also be used as the number key 8. |
|
When conducting analysis, this key allows the user to store the current reading in one of the 1000 sample data storage locations. Users can store readings with serial numbers from 1 to 1000 by pressing the "OK" button. Use the "△" and "▽" keys to find the unused storage serial number or use the numeric keys to directly enter the sample serial number. When the "#" graphic is displayed below the screen, this key can also be used as the number key 5. |
|
Start calling to store sample data (RECALL icon displayed in the upper left corner of the screen). When the "#" graphic is displayed below the screen, this key can also be used as the number key 2. |
|
Zero the instrument using the current sample blank. When the "#" graphic is displayed below the screen, it can also be used as the numeric key 0. |
|
Enter the settings menu (SETUP icon displayed in the upper left corner of the screen). The settings menu provides some options, such as reagent blank, standard adjustment, user input program, and instrument configuration. When the "#" graphic is displayed below the screen, it can also be used as the number key 9. |
|
Display the current time or date. Press once to display the date, press twice to display the time. Under the "Historical Data" menu, it is used to display the date or time of the called samples stored in the instrument. When the "#" graphic is displayed below the screen, this key can also be used as the number key 6. In the SETUP menu, this key is used to set the current date or time. |
|
Transform between displaying COD concentration, absorbance, and% transmittance. Press once to display concentration, press twice to display absorbance, and press three times to display% transmittance. Press again to return to the concentration display. When the "#" graphic is displayed below the screen, this key can also be used as the number key 3. |
|
When the READ icon is displayed at the bottom of the screen, pressing this key will read and display the sample concentration. When the "#" graphic is displayed below the screen, this key can also be used as a numeric key; Press once to display decimal numbers, and press twice or more to switch between positive and negative signs. |
|
When the 'back' icon is displayed below the screen, press the 'back' button to cancel the current input or selection. |
|
Scroll up within the selected menu. |
|
Scroll down within the selected menu. |
|
Select the displayed menu item in the menu. When entering a number, pressing this key indicates accepting the displayed value. |
The COD analyzer DR1010 kit includes the following types: (suitable for rapid detection)
The host includes:1.DR1010host2.The power adapter3.Data transmission cable(RS232Port, black, used for connecting computers)4.File package—Including instrument operation manual (including quick reference card), instrument method manual, and certificate of conformity.
DR1010 set includes:1. DR1010One set of instruments (9185000)2. DRB200A set of digestion equipment (LTV082.99.40001)
DR1010Package 2 includes:1. DR1010One set of instruments (9185000)2. DRB200A set of digestion equipment (LTV082.99.40001)3. Bottle mouth separator 2branch (9185400) 4. A set of high range large bottle reagents (2968000)5. One box of empty test tubes25branch (2517600) 6. One box of test tube caps25individual (2241125)
DR1010 set three includes:1. DR1010One set of instruments (9185000)2. DRB200A set of digestion equipment (LTV082.99.40001)3. Bottle mouth separator 2branch (9185400) 4. A set of low range large bottle reagents (2967900)5. One box of empty test tubes25branch (2517600) 6. One box of test tube caps25individual (2241125)
DR1010 set four includes:1. DR1010One set of instruments (9185000)2. DRB200A set of digestion equipment (LTV082.99.40001)3. Bottle mouth separator 3branch (9185400) 4. A set of high range large bottle reagents (2968000)5. A set of low range large bottle reagents (2967900) 6. One box of empty test tubes25branch (2517600)7. One box of test tube caps25individual (2241125)
The physical and chemical laboratory needs to analyze various data every day, especially a large amount of production wastewater analysis. The application of COD DR1010 greatly liberates manual laboratory testing time, and the timing function allows laboratory technicians to no longer be distracted by focusing on heating time, nor do they need to perform data calculations, reducing data errors caused by human factors. The data can be directly read by the instrument more accurately and quickly. The liberation of manpower and the saving of time are the improvement of production efficiency. The more links in the process, the more points where problems arise. HACH enables most of the links that are prone to problems to be controlled by itself, achieving fast and accurate analysis results.
In order to be closer to the Chinese market, better meet the needs of Chinese users, and help more and more domestic users solve the problems they encounter in the field of water quality monitoring, Hash (HACH) has started the localization of its products. While ensuring product quality, it has reduced many complex work processes, allowing more customers to use high-quality products with Hash (HACH) technology. HACH attaches great importance to the needs of Chinese users. Currently, products such as CODmax chromium method COD analyzer, 1900C portable turbidity meter, and DR1010 COD analyzer tailored specifically for the Chinese market have been favored by a large number of users for their product technology and quality. Localized production is becoming increasingly convenient for customers, shortening product delivery times and providing convenient and timely after-sales service support.
Hash COD analyzerIn addition to DR1010, various spectrophotometers can also be selected, such asDR3900 Hash Spectrophotometer、Portable photometer DR1900Wait.
HACH, Making water quality testing simple is worth having.