CV voltammetry electrochemical workstation experimental testing system
Measurement based on CV voltammetry electrochemical workstation experimental testing system: cyclic voltammetry CV, linear sweep voltammetry LSV, step
Product details

be based onCV voltammetry electrochemical workstation experimental testing systemMeasurement: cyclic voltammetry CV, linear sweep voltammetry LSV, step wave voltammetry SCV, chronoamperometry CA, chronoamperometry CC, current time curve I-t, electrolytic coulombic method BE, open circuit potential, battery charging and discharging, potential measurement, electrodeposition, electrochemical etching, leakage current, resistivity, etc.

Professional instrument equipment and testing solution supplier - JETYOO Industrial&Jianyou (Shanghai) Measuring Instrument Co., Ltd, formerly a product technical support engineer at Agilent (now KEYSIGHT) in Germany——Jian JETKEITHLEY, a loyal user engineer at Tektronix——RongyooCo founded in 2012, with the aim of breaking through the old and establishing the new! Fill the gap in the electronic measurement industry where agent distributors only specialize in business sales, lack expertise in pre-sales testing solutions, and lack expertise in after-sales training. Our technical sales engineers have a bachelor's degree or above and have over 10 years of work experience in the instrument industry, specializing in providing services to users in Chinabe based onCV voltammetry electrochemical workstation experimental testing system, a company located in the East China region of ShanghaiTechnology orientedA comprehensive service provider for instruments and equipment.

Preface:
The source meter can only measure small voltage, current, and resistance values, andKeithleybe based onCV voltammetry electrochemical workstation experimental testing systemBy applying algorithms, the measured values can be converted into the data and curve graphs you need. With this software, you only need one set of software for your source table, which is equivalent to adding several instrument testing functions. This source table+software is widely used in dozens of universities and research institutes across the country, greatly helping and enhancing professors in conducting scientific research experiments and writing papers and reports.


Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Dalian Institute of Physical Chemistry, Chinese Academy of Sciences, ShanghaiTech University, Southern University of Science and Technology, Peking University, Tsinghua University, Beijing Institute of Technology, Beijing Normal University, Beihang University, Beijing University of Posts and Telecommunications, East China Normal University, Donghua University, East China University of Technology, Shanghai Jiao Tong University, Fudan University, Shanghai University, Tongji University, ShanghaiTech University, Dalian University of Technology, Northeastern University, Jilin University, Northeastern Normal University, Harbin Institute of Technology, Harbin Engineering University, Nanjing University, Suzhou University, Jiangnan University, Nanjing University of Aeronautics and Astronautics, Southeast University, Nanjing Normal University, Nanjing University of Technology, Zhejiang University, University of Science and Technology of China, Hefei University of Technology, Anhui University, Xiamen University, Fuzhou University, Nanchang University, Shandong University, Ocean University of China, Zhengzhou University, Wuhan University, Wuhan University of Technology, Huazhong Normal University, Huazhong University of Science and Technology, Hunan University, Central South University, Sichuan University, University of Electronic Science and Technology of China, Northwest University, Northwestern Polytechnical University, Xi'an Jiaotong University, Lanzhou University are all being selectedbe based onCV voltammetry electrochemical workstation experimental testing system.

Keithleybe based onCV voltammetry electrochemical workstation experimental testing systemSupports 2601B, 2602B, 2604B, 2611B, 2612B, 2614B, 2634B, 2635B, 2636B source tables.
Due to the powerful features of this software, equipping your instrument with it is equivalent to adding the following instruments:
1. Authentic high-precision electrochemical workstation (DC).
2. Signal generator (sine wave, square wave, ramp wave, pulse).
3. Solar cell IV testing system.
4. Automated characteristic tester.
5. Modules can be freely combined to create your "customized instrument".
,,,,,,


Keithleybe based onCV voltammetry electrochemical workstation experimental testing systemThe main functions are summarized as follows:
1. Single order constant current/voltage output, applied to output constant current, voltage, measured voltage, current and resistance, can output V-T (voltage time), I-T (current time), R-T (resistance time) curves, three sampling modes (real-time single point, scan sampling, pulse sampling), can set sampling interval, arbitrarily define sampling duration, and can be used as constant current meter and constant potential meter in electrochemical applications.
2. Multi stage constant current/constant voltage output, capable of defining up to 20 different current and voltage segments for continuous output. Each segment can be set with output values, sampling intervals, and output times, and can be cyclically and continuously output. This function can form any order of current and voltage waveform output.
3. Segmented current/voltage scanning
Integrate 1 or N independent current and voltage scans into one testing function for output, with each interval independently defined starting and ending values, step sizes, and scanning intervals; Can automatically repeat loop execution. The following is a discontinuous three-stage scan


4. Continuous current/voltage scanning
Continuous current/voltage scanning divides a complete current scan into several intervals, and users can customize the starting and ending values and step sizes for each interval. The software combines these intervals to form a complete scan, and users can easily achieve unidirectional, bidirectional, and non-uniform scanning. The combination of these intervals is continuous and seamless during the scanning process, and the interval time between each scanning point is equal, without any output shutdown or pause in between.
Supports both DC and pulse scanning methods, and can automatically repeat the cycle execution.
5. Dual channel synchronous current/voltage scanning (limited to dual channel models only), can perform dual channel synchronous current/voltage scanning, supports both DC and pulse output modes, can automatically repeat the cycle execution, for both ends of the device, it is equivalent to testing two samples at the same time, increasing efficiency by 1 times.
6. Sine wave output, with defined amplitude and frequency, up to a maximum of 1KHz.


7. Square wave output, which can define high level, low level, duty cycle, and period.


8. Diagonal wave output


9. Pulse wave output
10. Electrochemical cyclic voltammetry measurement, directly realizing the cyclic voltammetry measurement of the electrochemical workstation, can set the starting and ending potential and scan rate, and can be automatically cycled.


11. Electrochemical multi current/potential step, up to 12 current/potential STEPS can be defined, with precise control of STEP time, sampling interval, cycle number, and higher accuracy than general electrochemical workstations.


12. Solar cell IV measurement: Conduct IV testing on solar cells and directly calculate the short-circuit current, open circuit voltage, maximum power, conversion efficiency, fill factor, and other results of solar cells based on irradiance, area, ambient temperature, temperature coefficient, and IV scan data.


13. Dual channel constant current and constant voltage output (limited to dual channel models only) can set channels A and B to constant current source and constant voltage source modes, while synchronously measuring.
14. Field effect transistor transfer curve measurement (limited to dual channel models only) supports unidirectional and bidirectional gate voltage scanning, as well as DC and pulse scanning.
15. Measurement of output curve of field-effect transistor (limited to dual channel models only) supports unidirectional and bidirectional drain scanning, as well as DC and pulse scanning.
16. Field effect transistor switch measurement (limited to dual channel models only) can define different voltage waveform measurements at the gate, measure drain current, and can be measured continuously and cyclically.
,,,,,,

,,,,,,

,,,,,,