Shandong Chuangxin Huayi Environmental Engineering Co., Ltd
Home>Products>CXLDF series environmentally friendly medical waste incinerator
CXLDF series environmentally friendly medical waste incinerator
CXLDF series environmentally friendly medical waste incinerator
Product details
The principle of incinerator is to use the combustion of coal, fuel oil, gas and other fuels to burn and carbonize the objects to be processed at high temperature, in order to achieve the purpose of disinfection.
At present, incinerators have significant application value in the harmless treatment of animal carcasses affected by diseases, as well as in the disposal of medical waste and toxic and hazardous solid waste.
Garbage enters the inclined downward grate through the feeding hopper (the grate is divided into a drying zone, a combustion zone, and a burnout zone). Due to the staggered movement between the grates, the garbage is pushed downward, allowing it to pass through various areas on the grate in sequence (when garbage enters another area from one area, it plays a large turning role), until it is completely burned and discharged from the furnace. Combustion air enters from the lower part of the grate and mixes with garbage; High temperature flue gas generates hot steam through the heating surface of the boiler, and the flue gas is also cooled. Then, the flue gas is treated by the flue gas treatment device and discharged.
Medical waste is mostly composed of plastic products, glass products, and residual drugs. If left untreated and discarded, it can greatly pollute the living environment and pose safety hazards to people's health. Medical waste incinerators are specialized equipment for incinerating medical waste and are essential waste disposal machinery in hospitals.
The medical waste incinerator consists of four major systems: waste pre-treatment system, incineration system, smoke biochemical dust removal system, and gas generator (auxiliary ignition incineration).
The medical waste incinerator integrates automatic feeding, screening, drying, incineration, ash cleaning, dust removal, and automation control.
The medical waste incinerator adopts high-tech measures such as high-temperature combustion, secondary oxygenation, and automatic slag discharge to meet the monitoring requirements of pollutant discharge.

1 LDFTechnical parameters of series incinerators

model

project

CXLDF-30

CXLDF-50

CXLDF-150

CXLDF-300

CXLDF-500

Incineration capacity

20-30/Times (can be burned every day)3-6Next time)

30-50/Times (can be burned every day)3-6Next time)

100-150/Times (can be burned every day)3-6Next time)

200-300/Times (can be burned every day)3-6Next time)

300-400/Times (can be burned every day)3-6Next time)

Incinerator sizemL×H×B

1.45×0.9×1.75

1.8×1.15×3

2×1.4×3.5

2.2×1.4×3.8

3×2×4.8

Size of garbage inlet()

480×600

620×800

760×960

900×1100

1080×1280

chimney()

outside diameterØ280

outside diameterØ280

outside diameterØ300

outside diameterØ400

outside diameterØ460

Induced draft fan

0.37kw

0.37kw

0.5kw

1.1kw

1.1kw

0.55kw

Combustion assisting burner

power0.11kw,Fuel consumption4-6/h

power0.11kw,Fuel consumption4-10/h

power0.11kw,Fuel consumption4-10/h

power0.22kw,Fuel consumption7-14/h

power0.22kw,Fuel consumption7-14/h

Reburning burner

power0.11kw,Fuel consumption4-6/h

power0.11kw,Fuel consumption4-10/h

power0.22kw,Fuel consumption7-14/h

power0.37kw,Fuel consumption10-20/h

power0.37kw,Fuel consumption15-26/h

operating voltage

380Vperhaps220V

380Vperhaps220V

380Vperhaps220V

380Vperhaps220V

380Vperhaps220V

Weight approximately(㎏)

2300

4000

7000

8000

13000

Note: Technical parameters are subject to change without prior notice.

II LDFIncineration technical indicators of series incinerators

Indicator waste type

Incinerator

Temperature (℃)

Smoke stop

Leave time(S

burn

Efficiency(%

Burn it down

Removal rate(%

Burning residues

Heat loss rate(%

Hospital clinical waste

850

2.0

99

99

95

IIILDFEmission standards for incinerator flue gas

Serial Number

Pollutant name

unit of measurement

GB18484-2001

1

Smoke blackness

Lingman level

1

2

smoke and dust

mg/m3

100

3

Carbon monoxide(CO

mg/m3

100

4

Sulfur dioxide(SO2

mg/m3

400

5

Hydrogen fluoride(HF

mg/m3

9.0

6

Hydrogen chloride(HCL

mg/m3

100

7

Nitrogen oxides(NO2

mg/m3

500