The wire and cable carbon black content tester is suitable for determining the carbon black content in polyethylene, polypropylene, and polybutene plastics. The testing of carbon black is obtained by weight analysis of the sample after high-temperature decomposition under nitrogen protection. This instrument has the advantages of easy use, simple operation, accurate measurement, high precision, and high degree of automation. This product has obtained a national patentCN304128957S

Compliant with standards: ISO 6964,GB/T 13021,IEC 60811-4-1,GB/T 2951.41,JTG E50 T1165, Wait.
Instrument features:
The appearance and structure of the instrument are beautiful, and the operation is simple;
The furnace door structure is an open type, which facilitates the placement of samples and the determination of their positions;
★ High degree of automation, simply set the temperature value and heating time, and the instrument will automatically heat up to the set value;
★ High temperature control accuracy, wide temperature range, and high uniformity of furnace temperature;
★ 7-inch LCD touch screen display, can be started with one click operation
★ It has excellent temperature control function and can set the temperature control time, with high temperature control accuracy;
The instrument can be set to 30 different heating time periods, with different heating temperatures, heating rates, and constant temperature times;
★ Comprehensive parameter display, showing the number of set groups, theoretical temperature, actual temperature, heating time (or constant temperature time);
During the operation of the instrument, the set parameters and the time for heating or constant temperature can be viewed;
model |
HS-TH-3500 |
Display mode |
7-inch LCD touch screen display |
Furnace tube size |
Inner diameter Ø 40 × 750mm |
Heating element |
Resistance wire |
Heating zone length |
200mm |
Length of constant temperature zone |
100mm |
working temperature |
≤1100℃ |
temperature range |
1200℃ |
temperature control |
Intelligent 30 segment programmable control |
Temperature control accuracy |
±2℃ |
Furnace door structure |
Open type |
Working power supply |
AC220V/50HZ/60HZ |
External dimensions Power |
540 * 300 * 460 [Width * Depth * Height] 3KW |
Standard configuration
Serial number |
describe |
quantity |
1 |
Atmosphere device |
1 unit |
2 |
Small tube furnace |
1 unit |
3 |
Burning Boat |
10 pieces |
4 |
Pipe blockage |
2 of them |
5 |
Crucible pliers |
1 piece |
6 |
High temperature gloves |
1 pair |
7 |
Quartz tube |
1 piece |
8 |
Rubber tube (1 meter, 3 meters) |
1 each |
Operation method of carbon black content detector:
1. Heat the combustion boat until it is scorching hot, then cool it in a dryer for at least 30 minutes, weigh it to the nearest 0.0001g. Place a polyethylene sample of (1.0 ± 0.1) g into a combustion boat and weigh it together, accurate to 0.0001g. Subtract the weight of the combustion boat from this weight to obtain the weight A of the polyethylene sample, accurate to 0.0001g. (The dryer needs to be self equipped)
2. First, place the combustion boat containing the sample in the middle of the quartz tube of the heating furnace, and then insert a rubber plug of an exhaust glass tube into one end of the glass combustion tube. Adjust the atmosphere device to allow nitrogen with an oxygen content of less than 0.5% to pass through the quartz tube at the required flow rate, and maintain this flow rate during the subsequent heating process.
3. Move the combustion boat to the instrument port and do not immediately remove it; After the combustion boat has cooled slightly in nitrogen, remove it and cool it in a dryer for 20-30 minutes before reweighing. Subtract the weight of the combustion boat and measure the weight of the residue to the nearest 0.0001g (residue weight B).
4. Then place the combustion boat into the glass combustion tube, and in step 4, adjust the atmosphere device to replace nitrogen with oxygen at an appropriate flow rate into the quartz tube of the glass combustion tube, so that the residual carbon black is completely burned. Take out the combustion boat and cool it down, weigh it, subtract the weight of the combustion boat, and measure the weight of the residue to the nearest 0.0001g (residue weight C).
5. Method for representing experimental results
Partial procurement customer cases