Guangdong Wanmu Instrument Co., Ltd
Home>Products>Chemical Luminescence Nitrogen Analyzer GWM-N200
Chemical Luminescence Nitrogen Analyzer GWM-N200
Working Principle: 1. The instrument adopts the principle of chemiluminescence detection. The sample undergoes high-temperature oxidation reaction, an
Product details

Working Principle

1The instrument adopts the principle of chemiluminescence detection. The sample undergoes high-temperature oxidation reaction, and the nitrogen compounds in it are quantitatively converted into NO2. The sample gas is dehydrated by a membrane dryer and enters the reaction chamber. The metastable NO reacts with O3 from the ozone generator in the reaction chamber and is converted into excited NO2. When the excited state of NO2 transitions to the ground state, photons are emitted, and the light signal is detected and received by a photomultiplier tube at a specific wavelength. By amplifying microcurrents and processing computer data, it can be converted into an electrical signal proportional to the intensity of light. The intensity of chemiluminescence is proportional to NO, and the amount of NO generated is proportional to the total nitrogen content in the sample. Therefore, the total nitrogen content in the sample can be determined by measuring the intensity of chemiluminescence.

2Execution standards: GB/T 17674、SH/T 0657、ASTM D5453-9


Product Overview

1、 The GWM-N200 chemiluminescence nitrogen analyzer is currently the most advanced nitrogen element synchronous analyzer in China, widely used to detect nitrogen content in liquid, solid, and gas samples.

2The instrument uses chemiluminescence to determine the total nitrogen content, and the key components of the system are imported, ensuring reliable performance of the entire machine.

3The instrument is suitable for measuring the total nitrogen content of paraffin oil, diesel, gasoline, lubricating oil, fuel oil, liquefied gas and natural gas, as well as other oil products, chemical raw materials and finished products.

Technical Parameters:

project

total nitrogen determination

Various types of samples

liquid

solid

gas

Measurement method

Chemiluminescence method (N)

Sample injection volume

1~50uL

1~100mg

1~10mL

measuring range

0.2~10000mg/L

measurement accuracy

Concentration value (ppm)

Injection volume (uL)

RSD(%)

0.2

20

25

5

10

10

50

10

8

100

10

5

More than 5000

5

3

Temperature control range and accuracy

Room temperature~1100 ℃, ± 1 ℃

Air source requirements

Argon: purity above 99.995%, oxygen: purity above 99.99%

Power requirements

AC220V±22V, 50Hz±0.5Hz,1500W

Instrument dimensions

660×510×420

Instrument weight

35Kg(Net weight 30kg)