Chemical pressure storage tank
Chemical pressure storage tank
Product details
Chemical pressure storage tank


Product parameters:
Product Name: Gas Storage Tank FLR-2000TS
Design pressure: 2.0MPa
Pressure vessel category: II

Design temperature: 80 ℃
Voltage resistance test: 2.5/MPa
Volume: 2.0m ³
Main material: Q345R
Working medium: 02
Manufacturing unit: Weifang Fulai Boiler Energy saving Equipment Technology Co., Ltd
Product Introduction:
A gas storage tank refers to a device specifically designed to store gases, while also stabilizing system pressure. Gas storage tanks are commonly used for storing and transporting gases. According to the different bearing pressures of gas storage tanks, they can be divided into ultra-high pressure gas storage tanks, high pressure gas storage tanks, low pressure gas storage tanks, and medium pressure gas storage tanks; According to the different metal materials used in gas storage tanks, they can be divided into stainless steel gas storage tanks, carbon steel stainless steel gas storage tanks, and alloy material stainless steel gas storage tanks. Gas storage tanks (pressure vessels) generally consist of parts and components such as cylinder, head, flange, connecting pipe, sealing element, and support.

Production and usage requirements for gas storage tanks:
Gas storage tanks are pressure vessels and must be manufactured and inspected by a pressure vessel manufacturing license unit before they can be installed and used. The commonly used media for gas storage tanks include compressed air, steam, water vapor mixtures, oxygen, other inert gases, etc. The pressure, temperature, and volume can be customized according to user needs.
Purpose of gas storage tank:
Function of gas storage tank: mainly used for medium pressure balance, buffering, and as a power source for transportation. The
Quality requirements for production of gas storage tanks:
Weifang Fulai Boiler Energy saving Equipment Technology Co., Ltd. has a special equipment manufacturing license for manufacturing D1 and D2 level pressure vessels. Weifang Fulai Boiler Energy saving Equipment Technology Co., Ltd. has established a rigorous quality assurance management system for "boilers" and "pressure vessels", and has integrated quality control throughout the entire process of marketing, design, procurement, production, inspection, and service, ensuring that users can receive good service.

1. Design control: In the product design process, strict adherence to relevant national standards and regulations, and the use of CAD assisted design effectively ensure the design quality of the product.
2. Material control: The company has equipment for testing the mechanical properties of materials and chemical analysis instruments, which monitor the main raw materials and ensure their reliable quality.
3. Inspection control: The company has multiple non-destructive testing personnel and complete testing methods, capable of conducting multiple tests such as X-ray abrasion, ultrasonic, surface testing, etc., ensuring material and welding process testing and quality control.
4. Process control: Standardize the process behavior of product components and the entire assembly process to ensure the stability and improvement of component and product quality.
5. Welding control: Strictly control the welding of the components, conduct welding tests and welding process evaluations in a timely manner. The company has welding personnel and certified projects that fully meet the requirements of boiler and pressure vessel manufacturing.

1、 Precautions for installation of gas storage tank
1. Environmental temperature: The environmental temperature at the installation site of the gas storage tank should be within the operating temperature range of this equipment. If it exceeds this range, measures should be taken to insulate or move it indoors with temperature regulation.
2. The installation environment should be free of corrosive media (gas or liquid). When designing the gas storage tank, slight corrosion (annual corrosion rate ≤ 0.14mm/year) is considered. If the annual corrosion rate exceeds 0.14mm/year in the usage environment, anti-corrosion treatment should be carried out to ensure safe operation of the equipment within the recommended service life of 10 years.
3. No valve shall be installed between the safety valve and the gas storage tank.
If the maximum intake flow exceeds the safe release capacity of the air storage tank, the user should install a pressure relief device in their system.
5. A hard pipe connection should be used between the gas storage tank and the gas source, and a buffer bend should be added.

2、 Management of gas storage tank usage
1. The user unit is responsible for the safety management of the use of the gas storage tank. Gas storage tanks that comply with the Safety Technical Supervision Regulations for Fixed Pressure Vessels need to obtain a registration certificate for use and undergo regular inspections by local testing departments. Gas storage tanks that fall within the scope of the "Regulations on Safety Technology Supervision of Simple Pressure Vessels" do not need to be registered for use and should be used according to their designed service life. If they need to continue to be used after reaching their service life, the using unit should report to a special equipment inspection and testing institution for regular inspection in accordance with the "Rules for Periodic Inspection of Pressure Vessels".
2. The user unit should establish a safety management file for each gas storage tank, conduct regular maintenance, inspection, and record storage of the gas storage tank. When abnormal situations are discovered, special equipment inspection and testing institutions should be promptly requested for inspection.
3. The unit using the gas storage tank should strictly follow the operating procedures, and regular professional training and safety education should be provided to the operators.
4. It is strictly prohibited to use the gas storage tank over temperature or pressure. The equipment should be regularly drained and cleaned to ensure that the gas storage tank is in normal working condition.
5. The safety accessories of the gas storage tank should be regularly calibrated according to relevant regulations to ensure that the safety accessories work properly.
6. In the event of an accident involving a gas storage tank, the unit responsible for the accident should promptly take effective measures, organize rescue efforts, prevent the accident from escalating, and report and handle it in accordance with the requirements of the "Regulations on the Handling of Special Equipment for Pressure Vessels". It is not allowed to conceal, delay reporting, or make false reports.