Lufthansa Technology Group Co., Ltd
Home>Products>Chlorolab2+liquid-phase oxygen electrode
Chlorolab2+liquid-phase oxygen electrode
2. Automatically collect data. Automatically calculate photosynthetic rate or respiration rate.
Product details

1. Highly integrated controller. Powerful control software. Control the light intensity and agitator speed

2. Automatically collect data. Automatically calculate photosynthetic rate or respiration rate.

3. Equipped with a controllable light source, the desired light intensity can be set by oneself, and photosynthesis can be automatically performed-Measurement of light intensity response curve and automatic calculation of photosynthetic quantum efficiency.

4. Can be withHANSATECHThe company'sFMS-2Simultaneous measurement of photosynthetic oxygen release rate and changes in chlorophyll fluorescence using a fluorescence analyzer



Origin and Manufacturer: UKHansatech


  • Sample dosage: 0.2-2.5ml (when light is required, the sample is prohibited from using vocabulary dosage of 1.5ml)

  • Measurement range: 0-100% O2

  • Oxygen resolution: 24 bit high-resolution measurement of O2At 20 ℃, the resolution is 10-3p mol· ml-1

  • Controller: Computer controller and integrated magnetic stirrer, capable of controlling light intensity and stirring rotor speed (150-900rpm), automatic data acquisition (0.1-10 times/second), 61 × 2 character LCD display, USB2.0 digital communication, supporting dual channel parallel use

  • Three types of light sources are available, all of which are fully automatic and controllable; The basic configuration is a white light source

  1. (1) Neutral white light source, maximum intensity 2000 μ mol · m-2·s-1You can set the required light intensity by yourself;

  2. (2)Red light source, wavelength 620-645nm, maximum intensity 2000 μ mol · m-2·s-1You can set the required light intensity by yourself;

  3. (3)Blue light source, wavelength 460-490nm, maximum intensity 2000 μ mol · m-2·s-1You can set the required light intensity by yourself;

  • Light source interface: 4 16mm diameter light source interfaces, which can also integrate fluorescence adapters to achieve integration with chlorophyll fluorescence meters. It can simultaneously measure parameters related to photosynthesis and chlorophyll fluorescence of experimental materials

  • Temperature control: The sample reaction chamber has a circulating water bath interlayer, which can be connected to an external circulating water bath for temperature control

  • Light/Temperature Gauge: Temperature Measurement Range: 0~50 ℃; Light intensity measurement range: 0~50000 μ mol · m-2·s-1