The most significant feature of corrosion-resistant magnetic float level gauges is that the liquid medium is completely isolated from the indicator, m
Product details
The most significant feature of corrosion-resistant magnetic float level gauges is that the liquid medium is completely isolated from the indicator, making them safe, reliable, and durable in any situation. Various models of level gauges are equipped with level alarms and control switches, which can achieve upper and lower limit alarms, control, or interlocking of the liquid level or boundary. When equipped with static pressure level transmitters or dry spring resistance level transmitters, the liquid level and boundary signals can be converted into two-wire 4-20mADC standard signals, enabling remote indication, detection, recording, and control. Suitable for liquid level measurement in corrosive media and high operating temperatures, with reliable structure and long service life. It is the best choice for measuring the liquid level of highly corrosive media such as hydrofluoric acid. Tailored for customers with low temperature and pressure requirements, our PP material level gauge can be used.
Anti corrosion magnetic flap level gauge
The stainless steel lined PTFE corrosion-resistant magnetic float level gauge adopts a stainless steel body lined with polypropylene (PP) and polytetrafluoroethylene (PTFE) technology, which has high structural strength and corrosion resistance, and can be applied to acidic liquids such as hydrochloric acid, alkaline liquids, and organic solvents. But it is not suitable for measuring concentrated nitric acid, chlorine containing solvents, aromatic agents, aliphatic and other medium liquids. There are two types of side mounted anti-corrosion magnetic float level gauges, with stainless steel body lined with polytetrafluoroethylene (PTFE) and stainless steel lined with polypropylene (PP), suitable for measuring corrosive media.
The side mounted lined magnetic float level gauge (PTFE) is suitable for measuring liquid levels in corrosive media and high operating temperatures. It adopts advanced stainless steel lined PTFE stretching and flanging technology, with reliable structure and long service life. It is the best choice for measuring the liquid level of highly corrosive media such as hydrofluoric acid.
The side mounted lined magnetic float level gauge (PP) is suitable for measuring inorganic corrosive liquids such as hydrochloric acid and dilute sulfuric acid. Due to the use of imported high-strength materials that can be close to metals, especially the unique insulation properties of PPR, this product is suitable for outdoor water tank level measurement and will not freeze inside in winter But it is not as good in temperature and pressure resistance as PTFE lining, and this product has a higher cost-effectiveness when the temperature and pressure are lower. Users can use remote transmitters according to engineering needs, which can achieve local digital display and output standard remote transmission electrical signals of 4-20mA to meet the needs of recording instruments or industrial process control. It can also be used in conjunction with magnetic control switches or proximity switches to monitor liquid level alarms or control inlet and outlet equipment.
Magnetic float level meter
Characteristics of corrosion-resistant magnetic float level gauge:
1. Using a float as the measuring element, the magnetic steel drives the float display without the need for energy.
2. Equipped with upper and lower limit switch outputs, it can achieve remote alarm and limit control.
3. Equipped with a transmitter, remote liquid level indication, detection, and control can be achieved.
Installation and maintenance of corrosion-resistant magnetic float level gauge
1. The installation of the liquid level gauge must be vertical to ensure that the float component can move freely up and down inside the main pipe.
2. Magnetic conductors are not allowed to approach the main body of the liquid level gauge, otherwise it will directly affect the correct operation of the liquid level gauge.
3. After the installation of the liquid level gauge is completed, it is necessary to calibrate the float with magnetic steel once to display red below zero and white above zero.
4. When the liquid level gauge is put into operation, the valve of the lower drainage pipe should be opened first to allow the liquid medium to smoothly enter the main pipe, avoiding the rapid rise of the liquid medium with the float component, which may cause the float to malfunction and flip randomly. If this phenomenon occurs, it can be recalibrated with magnetic steel after the liquid level stabilizes.
Basic technical parameters of corrosion-resistant magnetic float level gauge
1. Measurement range: 300-4000mm (can be specially customized when exceeding 5000mm)
2. Display accuracy: ± 10mm;
3. Work pressure: PP: Atmospheric pressure
4. Medium temperature: PP: -20~70 ℃;
5. Medium density: ≥ 0.5g/cm3;
6. Medium viscosity: ≤ 0.4Pa·S;
7. Process connection: DN2025/50/80/150 PN1.0 (executing standard HG20592~20635-97), if other standards are required, they can be manufactured according to customer requirements.
8. Liquid receiving material:/ PP and so on
9. Float material: 316L PVC/UPVC/CPVC/PP、PTFE、 Titanium, etc.