Czech Norton Coating Thickness Gauge
Usage: 1. Electroplating layer on steel products (zinc, chromium, nickel, cadmium, silver, tin, and other coatings). $n2、 Electroplating layers (zinc,
Product details

Product advantages:

  1. Automatically calculate the upper and lower limits of the average band.
  2. The measurement results are displayed in the statistical sample.
  3. Scan mode with upper and lower limit values.
  4. Diagonal2.4inchTFTColor display screen with built-in lithium battery.
  5. Ergonomic shock-absorbing design with rubber protection at the corners.
    6The keyboard comes with function keys that can be adjusted according to the device's working mode; The user interface is user-friendly and intuitive.
  6. Additional modes and device settings.
  7. Ergonomically designed small-sized wear-resistant sensor expansion component.
  8. Sensors that support multiple calibration features (forPH3Series probes, multiple supports6One; regardingNF-GProbe, multiple supports4One; regardingF-GProbe, multiple supports2A).
  9. 0.5 µm120 mm
  10. Additional single point calibration
  11. Two-point calibration
  12. Single point (with automatic multiplication correction)

USB 2.0thoroughfare

  • For devices:-30……+40
  • For sensors:-40……+50
  • +350
  • 3.74.2 V, 15001700 mАh
  • ×125×25mm
  • More than hours
  • hour
  • -3year
  • -2year

mini-USBUSB AType computer connection cable

FNF

  • 0-1500μm(1.5mm)
  • (0.015T + 1)μm
  • 6mm
  • Convex surface/concave surface Φ4mm/Φ12mm
  • :Φ21×90mm

  • K6-CofFThe series probe includes a calibration characteristic curve.

  • sexually
  • 0300μm 0.3mm
  • 0.02T+1) µm
  • :Φ3mm
  • straightfootpath:Φ4.5mm(Φ1 mm
  • :Φ9 ×34 mm
  • completeNot subject toThe influence of coating conductivity.

  • sexually
  • 0300μm 0.3mm
  • 0.02T+1) µm
  • :Φ3mm
  • straightfootpath:Φ4.5mm (Φ1 mm)
  • :Φ20×127 mm

  1. Cadmium, etc)Metal coatings are particularly suitable for insulation coatings (such as plastics, paints, etc.).

  • sexually
  • 0-500μm 0.5mm
  • ±(0.02T+1) µm
  • :Φ4mm
  • straightfootpath:Φ4.5mm (Φ1 mm)
  • :Φ9 ×65 mm
  • Wear resistant probe equipped with spring measurement systemHead, used for controlElectroplated coating, completelyNot subject toThe influence of coating conductivity.

  1. 2Millimeters.

  • 02000μm 2mm
  • ±0.02Tµm
  • :Φ6mm
  • straightfootpath:Φ9mm (Φ1.5 mm)
  • :Φ19 ×83 mm

Note: Probe equipped with spring measurement system. Use hard metal material as the probe front end to prevent probe wear.

  1. 6Millimeters.

  • 06000μm6mm
  • 0.02Tμm
  • :Φ8mm
  • straightfootpath:Φ10.5mm (Φ2.5 mm)
  • :Φ19 ×83 mm

Note: The probe with a spring measurement system is used for thick coating measurement.

F4

Measure the thickness of asphalt, plastic, metal foil, refractory materials, and other non ferromagnetic coatings (including specially designed coatings) on rough steel substrate surfaces.

Technical features:
Measurement range: 0-8mm

Measurement accuracy within the given range: 0-6 mm: ≤± (0.015T+0.01) mm; 6-8mm:≤±0.02T
Small substrate diameter: inner/outer diameter Φ 5mm/Φ 18.5mm

Diameter of measurement area: 12mm

Size: Φ 15 × 49mm

F5

Measure the thickness of asphalt, plastic, metal foil, refractory materials, and other non ferromagnetic coatings (including specially designed coatings) on rough steel substrate surfaces.

Technical features:

Measurement range: 0-10mm

Measurement accuracy within the given range: 0-8 mm: ≤± (0.015T+0.01) mm; 8-10mm:≤±0.02T

Small substrate diameter: inner/outer diameter Φ 7/Φ 57mm

Diameter of measurement area: 17mm

Size: Φ 23 × 58mm

  • K6-CofNFThe series probe includes a calibration characteristic curve.
  • 0.5Millimeters.

  • 0500μm0.5mm
  • :±0.02T+1) µm
  • :Φ1.5mm
  • :Φ6 ×35mm

  1. 2Millimeters.

  • 0-2000μm(2mm
  • :±0.02T µm
  • :Φ4.7mm
  • :Φ6 ×35mm
    Note:Probe and Spring Measurement SystemCombined,The use of modern materials ensures the high strength andSteel properties.

  • 0-15000μm(15mm)
  • µm
  • Φ20mm
  • Xiao Zhifootpath:Φ12mm(Φ5 mm
  • :Φ15 ×85mm

  • 030mm
  • µm
  • Φ40mm
  • straightfootpath:Φ45mm(Φ15mm
  • :Φ23 ×88mm

  • 070mm
  • 0-40mm:(1%±0.1)40-70mm: 2%
  • Φ90mm
  • straightfootpath:Φ270mm(Φ80mm
  • :Φ80×60mm

  • ofPHThe series probe includes a "coating/Matrix characteristic curve.

  • 0300μm
  • ≤±(0.03T + 1)µm
  • Φ4.7mm
  • Diameter: Φ1mm
  • :Φ12 ×40mm

  • PH3-0,2 || PH3-1,8
  • 0-120μm ||100μm
  • ≤±(0.03T + 1) ||≤±(0.03T + 1)µm
  • Φ1 mm ||Φ1mm
  • Diameter: Φ1 mm ||Φ75mm
  • :Φ6 ×50mm||Φ6×50mm