D10P-26Cyanide ion measuring instrumentDual channel structure with dual channelsBNCInterface, dual reference interface, dualATCInterface, can simultaneously connect twopHElectrode or ion selective electrode, for detecting impurities in the samplepHOr measure and display ion concentration simultaneously. Can easily, quickly, accurately, and economically measure cyanide ions in aqueous solutions.
D10P-26Cyanide ion measuring instrumentcharacteristic:
large screenLCDCan display measurement readings and temperature, as well as icons for battery level, electrode status, and calibration information
The prompt information at the bottom of the screen can help you with measurement, calibration, and menu settings
AUTO-READTMThe function can lock the reading and display an indicator icon when the data is stable
Calibration results can be viewed
Desktop instrument protection levelIP54Portable instrument protection levelIP67
All instruments can use power adapters orAAbattery
Automatically recognizableUSA/NIST/DINBuffer
D10P-26Cyanide ion measuring instrumentTechnical indicators:
PH: |
|
measuring range: |
-2.000 - 19.999 |
resolution: |
0.1 / 0.01 / 0.001 pH |
relative accuracy: |
±0.001 pH |
Correction point |
1 - 6drop |
Automatic buffer recognition |
US,NIST,DINCustomize with users |
ion concentration |
|
measuring range |
0 – 19900 M/ppm |
resolution |
1,2,3 Significant digits |
relative accuracy |
±0.1 mVperhaps0.05%(Choose the larger one) |
unit |
ppm,mg/L,M,%Or no unit |
measuring method |
Single known dosage/Reduction method; Double known dosage/decrement method |
Correction point |
2 - 6drop |
Oxidation-reduction potentialORP |
|
measuring range |
±1999.9(mV/RmV/EH) |
resolution |
0.1 mV |
relative accuracy |
±0.1 mVperhaps0.05%(Choose the larger one) |
temperature: |
|
measuring range/resolution: |
-5arrive105 °C / 99.9 °Cbelow0.1, 99.9 °Cthe above1.0 |
relative accuracy: |
± 0.1 °C |
display: |
Large screen backlightLCDSimultaneously display the measurement values of two channels |
input/output: |
|
Electrode input: |
twoBNCInterface, two reference electrode interfaces, twoMiniDINInterface (temperature probe) |
communication: |
two-wayRS232interface,optionalUSBcable |
GLPSoftware Features: |
|
Storage: |
1000 group |
Correction record: |
*After10Group correction data |
User method storage: |
20individual |
Superior self inspection: |
have |
Password protection: |
have |
Network software upgrade/download method: |
have |
power supply: |
Desktop:4 x AABattery; Universal power adapter |
safety certification: |
CE, CSA, UL, T? V, FCC Class A |
Suitable operating temperature: |
5 to 45 °C |
relative humidity: |
5 to 85% |
IPgrade: |
Desktop:IP54,Dustproof and splash proof |