Shanghai Zequan Technology Co., Ltd
Home>Products>DBSA710A DaqLink Temperature Collector
DBSA710A DaqLink Temperature Collector
Instrument Introduction: DBSA710A DaqLink Temperature Collector is an independent collector with USB communication interface
Product details

Instrument Introduction





DBSA710A_01.jpg

DBSA710AtypeDaqLinkThe temperature collector hasUSBIndependent collector for communication interface. built-in1A temperature sensor, the instrument has4Two extension interfaces with two wires, capable of measuring signals such as voltage, current, temperature, pulse, frequency, etc. Suitable for indoor and outdoor temperature monitoring.











Instrument characteristics





DBSA710A_02.jpg

ØAt most, it can be accurately measured16Bit resolution5An input signal

Øpass throughUSBConnect the data cable directly to the computer

ØCan be achieved throughLCDViewing data on the display screen

ØMeasurement can be started or stopped through panel buttons

ØCan be powered by rechargeable batteries for long-term field monitoring













Main technical parameters









ØInput Type

4to20mAsensor

Range: 4 to 20mA

Resolution: 47.6 μ A

Accuracy: ± 0.5%

Loop impedance: 21 Ω

0to50mVsensor

Range: 0 to 50mV

Resolution: 37 μ V Accuracy: ± 0.5%

Loop impedance: 25M Ω

Maximum voltage: 3.2V

0to1Vsensor

Range: 0 to 1V

Resolution: 200 μ V

Accuracy: ± 0.5%

Loop impedance: 25M Ω

Maximum voltage: 3.2V

PT-1002Line) temperature sensor

Range: -200 to 400 ℃

Resolution: 0.1 ℃

Accuracy: -200 to -60 ℃ ± 0.5%; 60 to 400 ℃ ± 0.5%- 60 to 60 ℃±0.3

JType thermocouple temperature sensor

Range: -200 to 1000 ℃

Resolution: 0.1 ℃

Accuracy: -200 to -60 ℃ ± 0.5%; 60 to 1000 ℃ ± 0.5%- 60 to 60 ℃± 0.5 ℃

Cold end temperature compensation: ± 0.3 ℃

KType thermocouple temperature sensor

Range: -200 to 1000 ℃

Resolution: 0.1 ℃

Accuracy: -200 to -60 ℃ ± 0.5%; 60 to 1000 ℃ ± 0.5%- 60 to 60 ℃± 0.5 ℃

Cold end temperature compensation: ± 0.3 ℃

TType thermocouple temperature sensor

Range: -200 to 400 ℃

Resolution: 0.1 ℃

Accuracy: -200 to -60 ℃ ± 0.5%; 60 to 400 ℃ ± 0.5%- 60 to 60 ℃± 0.5 ℃

Cold end temperature compensation: ± 0.3 ℃

Position Switch Scope: On/Off

Pulse counter (port only)4

Range: 1 to 65536

Resolution: 1 count frequency

Range: 0 to 4000Hz

Input signal: 0 to 3.2V

Input impedance: 470 Ω

Frequency (limited to ports only)4

Range: 20Hz to 4KHz

Input signal: 0 to 5V

Input impedance: 470 Ω

Built in temperature sensor

Range: -20 to 50 ℃

Resolution: 0.1 ℃

Accuracy: ± 0.3 ℃

Øtype of output

External power activation (for sensor use):

12VDC 300mA

Equipped with overload protection

Dry contact alarm output:

open-collector

Close position resistor:50Ω

Maximum load:50mA3VDC

Sampling characteristics:

Storage space: 59000 samples, depending on specific settings

Sampling interval:1sto18hOptional channel spacing:80dB

ØHardware parameters

display/key

2-line 16 character LCD display

2Independent button operation

Storage method

Cyclic/Non cyclic

storageButton Start

Storage pause

operate temperature

-20 to 50 ℃

Host placement box

ABS clinker boxSize:10.4 x 9.3 x 2.7 cm

Weight:153g

Can be fixed on a table or wall

Compatibility standards

CE/FCC/IC

Waterproof and dustproof standards:IP54
















Place of Origin:Fourtec, USA





Online inquiry