DCLRY-9High precision microcomputer based coal calorimeter(Can be dual controlled)Oxygen bomb automatic lifting,Automatic oxygenation
Related Name: Biomass Particle Fuel Calorimetry Analyzer Coal Briquette Calorimetry MeterFully automatic calorimeter; Microcomputer fully automatic calorimeter; Calorific value instrument
DCLRY-9High precision microcomputer based coal calorimeterScope of application
DCLRY-9High precision microcomputer fully automatic calorimeter/calorimeterUsed for measuringcoalCombustible solid or viscous liquid substances such as fuel oil, biomass particles, gangue bricks, etcCalorific value, in accordance withGB/T213-2008The CoalCalorific valueThe requirements of the measurement method.be used forCoal calorific valueBiomass fuel calorific valueBiomass pellet heat, fuel heat, brick body heatCoal fired calorific value、Biofuel truckThe calorific value of fuel oil is high,Oil heatCoal gangue bricks have a high calorific value, heavy oil fuel oil has a high calorific value, and straw has a high calorific valueTesting and analysis of the calorific value of methanol oil.
DCLRY-9High precision microcomputer based coal calorimeter(Technical parameters
Measurement accuracy: superior to national standardsGB/T213-2008
Usage environment:5-40℃(The temperature change should be measured every time)≤1℃)Relative humidity≤80﹪
Temperature resolution:0.0001℃
electricitySource:AC220V±15﹪50Hz
DCLRY-9High precision microcomputer based coal calorimeter((Can be dual controlled)It has the following performance characteristics
Oxygen bomb automatic lifting, easy to operate.
useComputer fully automatic controlThe advanced compressor electronic refrigeration technology is completely unaffected by changes in ambient temperature, ensuring that the temperature difference between the inner and outer cylinders of the instrument meets national standards. Can work continuously for 24 hours., Automatically adjust the temperature of the inner and outer cylinders, reduce the cooling correction factor, and make the measurement results more accurate. Adopting a unique refrigeration and temperature control system, the temperature rise and fall during the experimental process is0This ensures the stability and accuracy of the experimental results. The unique semiconductor refrigeration water circulation system can customize the cooling capacity based on the previous heat generation, balance the circulating water system, keep the water temperature relatively constant, reduce environmental impact, and perfectly solve the problem of continuous operation of calorimeter in the past4~5After the second experiment, the water temperature in the outer bucket exceeded room temperature1.5℃The common problem that leads to the inability to conduct continuous experiments is that the national standard requires that the temperature of the outer chamber and the room temperature during the experiment should not exceed1.5℃),Make the experimental results more accurate,Truly leveraging the advantages of a fully automatic calorimeter.
Stainless steel vacuum inner cylinder. The mixing system adoptsGerman original imported motor.
Fast testing speed, testing cycle ≤8min(Quick method)≤15min(National standard)GB/T213-2008).(National standard)GB/T213-2008).
Thermal capacity stability<0.2%Precision<0.1%temperature resolution0.0001K
such productEven in harsh environments, it has excellent performance and precision.
Compact structure, beautiful appearance, easy installation and maintenance, low failure rate.
Compact in size,Extensive use of molds for manufacturing, high precision.
The repeatability and reproducibility of coal calorific value testing are superior to the national standardGB/T212-2008The requirements.
High degree of automation, automatic utilization of the water volume in the built-in fixed container, automatic control of the temperature difference between the inner and outer buckets of the instrument, and automatic completion of the entire experimental process.
useWindowsXPThe operating system enables multiple controls on one machine, with no impact on each other's testing and high software stability.
The data processing function is rich, and users can easily query historical experimental data, current day data, parallel sample data, etc.
Meet national standardsGB/T213-2008The regulations“At the end, the inner cylinder is higher than the outer cylinder1Kabout”.
DCLRY-9High precision microcomputer based coal calorimeter((Can be dual controlled)It maintains all the functions of the microcomputer system and can run general software for other transaction processing. At the same time, starting the calorimeter measurement system can automatically calibrate the energy equivalent (heat capacity) and measure the heat generation of the calorimeter system. Input data such as sulfur, moisture, hydrogen, etc. to convert and print out data such as cylinder heat generation, high-level heat generation, low-level heat generation, etc.
The internal cylinder of the calorimeter device adopts electric stirring with sheet-like blades, and the external cylinder adopts submersible electric stirring, making the stirring more uniform and convenient. The instrument adopts a fused cotton thread ignition method.
Microcomputer calorimeter operationWinsowsXPOperating systems with Chinese character prompts and human-computer interaction throughout the entire process, ready to learn and use. Follow the prompts to complete the experiment.
DCLRY-9High precision microcomputer based coal calorimeter((Can be dual controlled)Standard configuration
Equipped with one computer, one printer, one oxygenator, one pressure reducer, one oxygen bomb, one bottle of potassium benzoate, five stainless steel or quartz crucibles, three sets of oxygen bomb sealing gaskets, and two rolls of ignition wire.
Hebi Dingcheng Thermal Analysis Instrument Co., Ltd——Mainly engaged in the research and production of high, medium, and low-end calorific value detection, fuel calorific value meters, coal quality analysis instruments, coal detection equipment, and fuel oil calorific value analysis instruments. It is a specialized high-tech enterprise with years of design and manufacturing experience, integrating product research and development, production, sales, and technical services. The main series of products includeThe main products of the company are:Determination of calorific value of coalInstrument, biomass fuel calorific value detectorBiomass pellet heat detectorFuel calorific value testerBrick body calorific value and heat detectioninstrument、Coal fired calorific value tester、Biofuel large card detectorFuel oil calorific value large card detector,Oil heat detector、Coal gangue brick body calorific value detector, heavy oil fuel oil calorific value large card detector, straw calorific value large card detectorA calorimeter for measuring the calorific value of methanol oil,Coal thermal analyzer、High calorific value of biofuelsDetector, Biomass Particle Fuel Calorimeter, Heavy Oil Fuel Calorimeter, Straw CalorimeterParticle fuel sulfur analyzerThermal analysis instrument.