Shanghai Xuke Electric Appliance Co., Ltd
Home>Products>DL-10 series current relay
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15800491905
  • Address
    No. 618 Jianyun Road, Zhoupu Town, Pudong New Area, Shanghai
Contact Now
DL-10 series current relay
Application scope: The DL-10 series current relay is an electromagnetic instantaneous overcurrent relay widely used in power systems
Product details


DESCRIPTION

DL-10 seriescurrent relay

1、 Application scope
DL-10 seriescurrent relayIt is an electromagnetic instantaneous overcurrent relay widely used in secondary circuit relay protection devices of power systems as an overcurrent starting element.
2、 Main technical reference data

model Maximum setting value setting range Coil series connection Parallel connection of coils power Number of contact points return
action current action current consume Dynamic combination Dynamic interruption coefficient
DL-11/12/13 0.01A 0.0025-0.01A 0.0025-0.005A 0.005-0.01A ≤7VA 1 1 ≥0.8
DL-11/12/13 0.04A 0.01-0.04A 0.01-0.02A 0.02-0.04A ≤7VA 1 1
DL-11/12/13 0.05A 0.0125-0.05A 0.0125-0.025A 0.025-0.05A ≤7VA 1 1
DL-11/12/13 0.2A 0.05-0.2A 0.05-0.1A 0.1-0.2A ≤7VA 1 1
DL-11/12/13 0.6A 0.15-0.6A 0.15-0.3A 0.3-0.6A ≤7VA 1 1
DL-11/12/13 2A 0.5-2A 0.5-1A 1-2A 0.5-1A 1 1
DL-11/12/13 6A 1.5-6A 1.5-3A 3-6A ≤3.5VA 1 1
DL-11/12/13 10A 2.5-10A 2.5-5A 5-10A ≤3.5VA 1 1
DL-11/12/13 15A 3.75-15A 3.75-7.5A 7.5-15A ≤3.5VA 1 1
DL-11/12/13 20A 5-20A 5-10A 10-20A ≤3.5VA 1 1
DL-11/12/13 50A 12.5-50A 12.5-25A 25-50A ≤3.5VA 1 1
DL-11/12/13 100A 25-100A 25-50A 50-100A ≤3.5VA 1 1
DL-11/12/13 200A 50-200A 50-100A 100-200A ≤3.5VA 1 1 ≥0.7

Action time: At 1.1 times the measured action value, the action time should not exceed 0.12 seconds; When the actual action value is doubled, the action time should not exceed 0.04 seconds.
Contact capacity: In a DC inductive load circuit with a voltage not exceeding 250V, a current not exceeding 5A, and a time constant of 5 ± 0.75ms, the output contact of the product has a breaking capacity of 50W. The output contact can reliably operate and return 5 × 104 times under the specified load conditions. The long-term allowable current for the output contact is 5A.
Dielectric strength: When the conductive terminals of the product are connected together, they can withstand an AC voltage of 2000V (effective value) 50Hz for 1 minute without insulation breakdown or flashover between exposed non charged metal parts or shells.
3、 Internal wiring



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!