Wuxi Hengtong Electric Appliance Co., Ltd
Home>Products>DPCJKW95 Multi functional Distribution Transformer Monitoring System
DPCJKW95 Multi functional Distribution Transformer Monitoring System
DPCJKW95 Multi functional Distribution Transformer Monitoring System
Product details
DPCJKW95 Multi functional Distribution Transformer Monitoring System
The DPCJKW95 multifunctional distribution transformer monitoring system realizes real-time monitoring and control of public distribution transformers, plant specific transformers, distribution cabinets, substation outgoing lines, and other equipment in the distribution network. This distribution transformer monitoring system can enable us to timely grasp the operating parameters of the distribution station area, understand the operating status of electrical equipment, provide scientific basis for line loss analysis, load forecasting, voltage qualification rate statistics, power supply schemes, distribution network planning, user power connection and other businesses, improve the level of economic and safe operation, and scientifically carry out low-voltage power supply planning, real-time comprehensive monitoring of distribution transformer operating parameters, and achieve automatic management of low-voltage distribution networks.
   1. Main functions of the system:
1) It can measure and display voltage, current, frequency, active power, reactive power, active power, reactive power, apparent power, and power factor; Frequency range: DC and 40Hz~70Hz, power factor:- 1~+1;
2) It can display and store the 2-31st harmonic components, harmonic content, and total distortion rate of three-phase voltage and current;
3) Fault display and alarm include phase loss, overvoltage, undervoltage, overcurrent, harmonic over limit, etc;
4) It can statistically analyze the large and small values and occurrence time of voltage, current, active power, etc., as well as the time when the voltage exceeds the upper and lower limits, and the time when the power line is cut off;
5) Remote timing function.
6) Based on the collected voltage and power factors, an optimal solution can be adopted to automatically control the switching of reactive capacitor banks on site, regulate the output voltage of distribution transformers, and improve power factors.
7) Voltage qualification rate statistics, load analysis, and line loss analysis functions
8) Electricity theft alarm and analysis function.
9) Set parameters and perform fault diagnosis functions through the main station.
2. Distribution Transformer Monitoring Master Station Software System
Introduction
As a part of the distribution transformer monitoring system, the distribution transformer monitoring software realizes the expected functions of data acquisition, storage, query, analysis, monitoring, and control on the basis of hardware; Simultaneously implement other auxiliary functions, such as data import and export, permission management, asset management, system configuration, etc. The software analyzes and processes the operating data of transformers, conducts line loss analysis, generates operation fault alarms and equipment theft alarms through methods such as continuous inspection and receiving terminal reports, thereby improving the economy and safety of distribution network operation.
The transformer monitoring software adopts a B/S structure, complies with relevant standards, provides a user-friendly interface, and has high software system robustness.
Main functions
1) B/S structure, convenient software distribution and maintenance upgrade functions.
2) Adopting a large-scale database DB2 and a three-tier architecture, it provides secure, reliable, and high-speed storage of massive data.
3) The data import/export function facilitates the sharing of data between various systems.
4) Comply with national standards and power company industry standards for data communication and data analysis.
5) Convenient system hardware asset management function, and can share data with other software systems.
6) Powerful user permission management function ensures that system functions are not used beyond authorization and provides system security.
7) The comprehensive system maintenance function allows for easy setting of software parameters and management of the system.
8) The convenient data reading function allows operators to conveniently, accurately, and real-time read distribution transformer data.
9) The online monitoring function allows operators to monitor the operation of critical components in the system.
10) Prominent and comprehensive alarm function, with a separate pop-up interface for alarm information, reminding users of the occurrence of an alarm; The alarm response strategy provides a basis for accountability.
11) The powerful logging function allows for the traceability of the system's operation and performance.
12) Flexible and powerful data query function, users can combine queries according to various conditions, or use the convenient query conditions provided by the system.
13) In line with industry habits, the data analysis function with artificial intelligence color provides users with display of analysis results in the form of curves, histograms, pie charts, etc.
14) The interlocking control function of the software establishes constraints between several parameters to ensure that the software does not issue incorrect operating instructions and guarantees the safe operation of the system.
15) The reactive power compensation parameter setting function can set action conditions and report the switching status of compensation capacitors according to actual needs.
Data copying and reading
Automatic line loss statistics
voltage curve

Online inquiry