Dalong MicroPette PlusFully disinfected manually&Fixed typePipette
The fully disinfected pipette can be used121℃,1atmUnder conditions of high temperature and high pressure disinfection of the entire unit20Minutes, no special preparation is needed to disinfect the entire tube. After disinfection, it must be placed over12Allow it to cool and dry thoroughly within hours.It is recommended to check the performance of the pipette after each round of high-temperature and high-pressure disinfection. It is also recommended that every10Re lubricate the piston and sealing ring of the pipette after sub high temperature and high pressure disinfection.
Characteristics of single channel pipette
-Lightweight and designed to conform to ergonomics
-Digital window, making the set range clear at a glance
-Wide range of measurement,0.1μlto10ml
-Using attachment tools allows for convenient and efficient calibration and maintenance
-Accurate liquid separation, each pipette is operated according toEN/ISO8655Standard calibration
-The entire unit can withstand high temperature and high pressure disinfection
-Adopting new materials and high-temperature and high-pressure resistant structures
The multi-channel pipette also has the following innovative features
-The nozzle ejector can simultaneously eject multiple suction nozzles, which is efficient and labor-saving
-Various ranges of8Dao and12The pipette is suitable for standard use96perforated plate
-Liquid head can360Rotating degrees, convenient for pipetting
-Each nozzle connection has an independent piston device, making maintenance and repair convenient
-Special nozzle connector design, easy to observe the sealing condition of the suction nozzle
Ordering Information
MicroPette plusSingle channel manually adjustable pipette |
Item number |
range |
increment |
Measure volume(μl) |
Allow * * system error (Inaccuracy) |
Allow * * random error (Inaccurate) |
|
|
|
|
% |
μl |
% |
μl |
|
0.1-2.5μl |
0.05μl |
2.5 |
2.50% |
0.0625 |
2% |
0.05 |
1.25 |
3% |
0.0375 |
3% |
0.0375 |
0.25 |
12% |
0.03 |
6% |
0.015 |
|
0.5-10μl |
0.1μl |
10 |
1% |
0.1 |
0.80% |
0.08 |
5 |
1.50% |
0.075 |
1.50% |
0.075 |
1 |
2.50% |
0.025 |
1.50% |
0.015 |
|
2-20μl |
0.5μl |
20 |
0.90% |
0.18 |
0.40% |
0.08 |
10 |
1.20% |
0.12 |
1% |
0.1 |
2 |
3% |
0.06 |
2% |
0.04 |
|
5-50μl |
0.5μl |
50 |
0.60% |
0.3 |
0.30% |
0.15 |
25 |
0.90% |
0.225 |
0.60% |
0.15 |
5 |
2% |
0.1 |
2% |
0.1 |
|
10-100μl |
1μl |
100 |
0.80% |
0.8 |
0.15% |
0.15 |
50 |
1% |
0.5 |
0.40% |
0.2 |
10 |
3% |
0.3 |
1.50% |
0.15 |
|
20-200μl |
1μl |
200 |
0.60% |
1.2 |
0.15% |
0.3 |
100 |
0.80% |
0.8 |
0.30% |
0.3 |
20 |
3% |
0.6 |
1% |
0.2 |
|
50-200μl |
1μl |
200 |
0.60% |
1.2 |
0.15% |
0.3 |
100 |
0.80% |
0.8 |
0.30% |
0.3 |
50 |
1% |
0.5 |
0.40% |
0.2 |
|
100-1000μl |
5μl |
1000 |
0.60% |
6 |
0.20% |
2 |
500 |
0.70% |
3.5 |
0.25% |
1.25 |
100 |
2% |
2 |
0.70% |
0.7 |
|
200-1000μl |
5μl |
1000 |
0.60% |
6 |
0.20% |
2 |
500 |
0.70% |
3.5 |
0.25% |
1.25 |
200 |
0.90% |
1.8 |
0.30% |
0.6 |
|
1000-5000μl |
50μl |
5000 |
0.50% |
25 |
0.15% |
7.5 |
2500 |
0.60% |
15 |
0.30% |
7.5 |
1000 |
0.70% |
7 |
0.30% |
3 |
|
2-10ml |
0.1ml |
10ml |
0.60% |
60 |
0.20% |
20 |
5ml |
1.20% |
60 |
0.30% |
15 |
2ml |
3% |
60 |
0.60% |
12 |
8Dao manual adjustable pipette |
Item number |
range |
increment |
Measure volume(μl) |
Allow * * system error (Inaccuracy) |
Allow * * random error (Inaccurate) |
|
|
|
|
|
% |
μl |
% |
μl |
|
|
0.5-10μl |
0.1μl |
10 |
1.50% |
0.15 |
1.50% |
0.15 |
|
5 |
2.50% |
0.125 |
2.50% |
0.125 |
|
1 |
4% |
0.04 |
4% |
0.04 |
|
|
5-50μl |
0.5μl |
50 |
1% |
0.5 |
0.50% |
0.25 |
|
25 |
1.50% |
0.375 |
1% |
0.25 |
|
5 |
3% |
0.15 |
2% |
0.1 |
|
|
50-300μl |
5μl |
300 |
0.70% |
2.1 |
0.25% |
0.75 |
|
150 |
1% |
1.5 |
0.50% |
0.75 |
|
50 |
1.50% |
0.75 |
0.80% |
0.4 |
|
12Dao manual adjustable pipette |
Item number |
range |
increment |
Measure volume(μl) |
Allow * * system error (Inaccuracy) |
Allow * * random error (Inaccurate) |
|
|
|
|
|
% |
μl |
% |
μl |
|
|
0.5-10μl |
0.1μl |
10 |
1.50% |
0.15 |
1.50% |
0.15 |
|
5 |
2.50% |
0.125 |
2.50% |
0.125 |
|
1 |
4% |
0.04 |
4% |
0.04 |
|
|
5-50μl |
0.5μl |
50 |
1% |
0.5 |
0.50% |
0.25 |
|
25 |
1.50% |
0.375 |
1% |
0.25 |
|
5 |
3% |
0.15 |
2% |
0.1 |
|
|
50-300μl |
5μl |
300 |
0.70% |
2.1 |
0.25% |
0.75 |
|
150 |
1% |
1.5 |
0.50% |
0.75 |
|
50 |
1.50% |
0.75 |
0.80% |
0.4 |
|
Manually fix the pipette |
Item number |
range |
increment |
Measure volume(μl) |
Allow * * system error (Inaccuracy) |
Allow * * random error (Inaccurate) |
|
|
|
|
|
% |
μl |
% |
μl |
|
|
5μl |
- |
5μl |
1.3% |
0.065 |
1.2% |
0.06 |
|
|
10μl |
- |
10μl |
0.8% |
0.08 |
0.8% |
0.08 |
|
|
20μl |
- |
20μl |
0.6% |
0.12 |
0.5% |
0.1 |
|
|
25μl |
- |
25μl |
0.5% |
0.125 |
0.3% |
0.075 |
|
|
50μl |
- |
50μl |
0.5% |
0.25 |
0.3% |
0.15 |
|
|
100μl |
- |
100μl |
0.5% |
0.5 |
0.3% |
0.3 |
|
|
200μl |
- |
200μl |
0.4% |
0.8 |
0.2% |
0.4 |
|
|
250μl |
-- |
250μl |
0.4% |
1.0 |
0.2% |
0.5 |
|
|
500μl |
- |
500μl |
0.3% |
1.5 |
0.2% |
1.0 |
|
|
1000μl |
- |
1000μl |
0.3% |
3.0 |
0.2% |
2.0 |
|
|
2000μl |
- |
2000μl |
0.3% |
6.0 |
0.15% |
3.0 |
|
|
5000μl |
- |
5000μl |
0.3% |
15 |
0.15% |
7.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|