DeltaTox II portable water toxicity analyzer and biological pollutant analyzer
DeltaTox IIPortable water toxicity analyzer,Specially designed for rapid and accurate detection of various water toxicity and biological pollutants on site, as well as laboratory testing needs, using luminescent bacteria - Fischer fox fungus as the detection of live organisms, detecting the intensity of light produced by luminescent bacteria to determine the presence and degree of toxicity of the tested substance. Fast detection process(5Minute by minute, comprehensive, built-in automatic temperature control, self calibrating luminosity, can minimize false alarms or omissions, and ensure the reproducibility of results. Can simultaneously detect and analyze chemical toxicity and biotoxin contamination. Can be more than2800Accurately detect harmful substances and chemicals. Can be applied to counter-terrorism, emergency response, and early warning monitoring; Comprehensive evaluation of lake basins; Safety assessment of source water and drinking water; Rapid on-site monitoring of various pollution accidents; Comprehensive evaluation of pollutant emissions; Food safety analysis; Toxicity reduction assessment(TRE’S)Toxicity identification and evaluation(TIE’S)And various sudden environmental pollution accidents.
Portable design can also be used for field testing, vehicle mounted testing, and various occasions. Easy to use and achieve results in a few minutes. Test data can be stored for later download and analysis.
l Principle of toxicity testing:
The equipment adopts a method recognized by authoritative institutions: the biotoxicity detection sensor - Vibrio fischeri luminescent bacteria is used to detect live organisms, which provides an effective detection method to deal with water pollution (whether caused by intentional destruction or sudden accidents). Due to the fact that acute toxicity testing can be conducted5~30Completed within minutes, ensuring rapid response to changes in water quality.
This bacterium emits light during metabolism. The strength of the toxicity of water samples can be expressed by comparing the degree of light attenuation with the non-toxic control blank experiment. Due to the fast testing process, the relative concentration of toxic substances in the water sample can be determined by diluting the test sample. This method can also be used to determine what treatment processes (disinfection, filtration, adsorption, heating, etc.) can eliminate or neutralize toxic substances in water.
l Advantages and characteristics:
Standard methods recognized by authoritative institutions
l SDIcompanyDeltatox ®II has been acquired by the United StatesEPARecommended for use;2007In China, the standards were revised based on this equipment and technology, namelyGB/T15441-1995Determination of Acute Toxicity of Water Quality by Luminescent Bacteria Method;
l Detection of luminescent bacteria used: Fischer fox bacteria(Vibrio fischeri NRRL B-11177)It has become a designated luminescent bacterium for toxicity testing standards in international and multiple countries, and follows the following standards:
1. ISO11348-3Determination of Water Quality - Determination of the Inhibition Effect of Water Samples on Luminescent Bacteria(3)》;
2. ASTM-D-5660Standard Test Method for Evaluating Microbial Detoxification of Chemical Contaminated Water and Soil through Toxicity Testing of Marine Luminescent Bacteria;
3. DIN 38412-37-1999Determination of the inhibitory effect of water on the growth of phosphorus containing bacteria in the genus Actinobacteria (Cell Growth Inhibition Test)(L37)》;
l Numerous professional laboratories and research institutions around the world use itSDIResearch on equipment and published papers500More articles.
l AmericaEPAThe Technical LaboratoryETVThe verification results indicate that the device's detection data is accurate and reliable.
l Technical certification from authoritative institutions: Possessing the Emergency Product License from the US Department of Homeland Security.
l The portable toxicity detector has high reliability:
1. The highest repeatability and minimum experimental error: according to the United StatesEPA2003The annual verification comparison results have been obtained, and it has been confirmed that the coefficient of variation is20%Internally, similar to chemical analysis methods, it is significantly superior to other biological tests.
2. The sensitive range of the device is close to the toxic range that humans can react to, and it is highly correlated with the results of animal experiments.
3. The sensitivity of the experiment is excellent: it can quickly detect over5000The existence of poisonous substances.
4. The standard deviation of the determination results for common toxic substances is ≤10%(USEPABased on the testing report.
5. Deltatox ®The standard deviation of the determination results for common interfering toxic substances is ≤12%(USEPABased on the testing report.
l Progressiveness:
l Progressiveness of poison detection equipment:
1. Equipment provides testing time:5 、10、15、20... minutes;
2. Deltatox ®II has accurate environmental temperature measurement and automatic locking function, providing good detection of environmental temperature for the normal operation of luminescent bacteria10~28ºC;
3. Deltatox ®II Optional Microbial Total QuantityATPDetection of microorganisms in drinking waterATPThe minimum detection limit for detection is:100cfu/ml
l Progressiveness of software functions:
1. Professional experimental software includes27Standard methods and operating procedures, such as:ISO11348-3、ASTM-D-5660、DIN 38412It can meet various toxicity analysis requirements.
2. Luminous loss rate%Toxicity inhibitory concentrationECIt is automatically calculated by software and does not require the use of other auxiliary tools;
3. The detection time is automatically controlled by software: each sample can be set3Continuous detection time,Automatic Accumulation,And automatically prompt and switch;
4. Support single sample analysis or continuous multi sample testing; All data is automatically processed and displayed, which can accurately control the detection process, provide automatic prompts, and automatically save data.
l Specification Description:
Types of detectable toxic substances:> 2800species
Detection mode:Toxicity (Q-Tox and B-Tox) and ATP measurement,111 Pencader Drive Newark, DE 19702 USA P 302.456.6789 F 302-456-6782 T 800.544.8881 USA
operation temperature: 0°C ~40°C
Reagent operating temperature: ten°C~28°C
Test concentration:90%Or lower concentration
Reagent storage:-15°C~-25℃
display output:BacklightLCD(8Okay, x 20Characters)
data processing:built-inUSBPort, standalone or downloaded to a computer, with built-in prompts in the software for operation steps, recording light measurements, and immediately reviewing automatically calculated results and further analysis results.
Memory card: 6.5k (make an appointment600 reads)
Dimensions: 200x 180 x 100mm
Weight: 1 kg
Power Supply:Li-On rechargeable,The power adapter(15 V dc @ 4A)
authentication:CE