Dry type transformer temperature controller (embedded)
Dry type transformer temperature controller (embedded)
Product details

Product panorama:

产品全景图

注意事项

Click here to watch in full screen

Product Overview

This instrument is a new generation computer temperature controller designed by our company for the new air-cooled dry-type transformer. It uses a single-chip computer produced in the United States as the control core and is designed with the most advanced data storage technology, thus taking the performance of the entire product to a new level. Compared with traditional temperature controllers composed of analog and digital circuits, this instrument uses a high-performance microcomputer controller, which reduces the number of electronic components required by more than half, greatly simplifying the circuit and structural design of this instrument and greatly improving its operational reliability. The temperature controller produced by our company can be set by simply pressing a few buttons on the panel, and the set parameters will never be lost after a power outage. This instrument also has a "black box" function, which can record the temperature of the wire winding of the transformer at the time of power failure. In terms of anti-interference, this instrument adopts a combination of hardware and software anti-interference measures in its design, jointly monitoring the operation of the temperature controller, thus achieving extremely strong anti-interference ability. In terms of use, this instrument also has the characteristics of simple operation, easy installation, and easy maintenance.
This product complies with the JB/T7631-2005 "Electronic Temperature Controllers for Transformers" standard
The production system of this product has passed ISO9001:2000 quality system certification.
This product has been evaluated by the National Science and Technology Commission and the National Economic and Trade Commission as a national key new product for the year 1997

Two technical parameters
1. Temperature measurement range:- 30℃-200℃
2. Temperature measurement accuracy: 0.5% FS ± 1 word
3 Resolution: 0.1℃
4 Working voltage: AC176V~AC242V (50Hz)
5 Power consumption: 5VA
6-point capacity 10A/AC220V
7 Sensors: Three Pt100 Platinum Thermistors
8 Relay Contact Capacity: 10A/250VAC
9. Instrument weight: < 1Kg
10 Instrument dimensions: 160 × 80 × 134 (width x height x depth)
Hole size: 152x76 (width x height)


Introduction to Three Product Functions
1. It has the function of switching between the circulating display of three-phase wire package temperature and the display of the highest phase temperature.
2. The fan can be automatically controlled to turn on and off according to the set temperature for opening and closing the fan, ensuring the safe operation of the dry-type transformer at normal temperatures. When the highest phase temperature in the three-phase wire package exceeds the fan opening temperature, the fan will turn on and the "fan" indicator light on the panel will light up.
3 has an over temperature alarm function. When the highest phase temperature in the three-phase wire package reaches the over temperature alarm temperature, the temperature controller will emit a buzzing alarm, the "over temperature" light on the panel will turn on, and the "alarm" output terminal on the back panel will output a switch signal to the remote control cabinet to control the sound and light alarm.
4 has an automatic tripping function. When the highest phase temperature in the three-phase wire package reaches the over temperature tripping temperature, the temperature controller will sound a buzzer alarm, the "trip" light on the panel will light up, and the "trip" output terminal on the back panel will output a switch signal to cut off the power and protect the dry-type transformer.
When any phase of the 5 sensors has a fault, the "fault" indicator light on the panel will light up, and there will be a buzzing alarm inside the temperature controller. The switch signal will be output through the "fault" output terminal on the back panel (the temperature controller with AC380V three-phase fan output mode has no fault output terminal).
5.1 Displaying H in the temperature display area indicates that the phase is open circuit; Displaying L indicates that the phase is short circuited.
When one or two phases of the sensor fail, only control the fan based on the temperature signal of the good phase sensor. If all three sensors fail simultaneously, immediately turn on the fan.
6. The fan on temperature, fan off temperature, over temperature alarm temperature, over temperature trip temperature, timed fan on time, and local communication number can be directly set through buttons, and data will not be lost during power failure.
7 has the function of manually controlling the fan, which can be manually turned on/off. This function can also be used as a test fan function.
8 has the function of timed opening of the fan, and users can set it for 0-255 hours on the panel (when set to 0, it means this function is cancelled). When the timed time reaches the set time, the fan will automatically run for 2 minutes and then stop.
9 has a "black box" function, which records the three-phase temperature at the time of power outage in memory for future reference. In order to avoid changing the memory data due to power failure after being powered on again, it is stipulated that the original recorded temperature will not be refreshed when the temperature before power failure is below 80 ℃.
10 simulation detection function, which can manually simulate the control function of the temperature controller.

Four product operation instructions(See panel diagram in Figure 1)

(1) Panel schematic diagram

Figure 1 Panel Diagram


(two)Operating instructions

1 Power on:After the thermostat is powered on. Tour displayABCTemperature of three-phase wire package.

2 Display mode switching operation:Press the "highest" button to display the highest phase temperature in the three-phase wire package, and the "highest" light will turn on at the same time; Press the 'highest' button again to return to the circuit display of three-phase temperature status, and the 'highest' light will turn off.

3 Manual switch fan operation:Press the "Manual Fan" button to manually start/Stop the fan. The "manual" light indicates the current status of manually operating the fan.

4 Power off data query operation:Press the "Query" button continuously to display the temperature of the A, B, and C three-phase wire packages in sequence during the last power outage

5 Query operation of control parameters

step

key

display

speak bright

have pour

1

Press the 'Function' button

1-080

Indicates that the fan temperature is turned off80

The preset value is80

2

Press the 'Function' button

2-100

Indicates that the fan temperature is100

The preset value is100

3

Press the 'Function' button

3-130

Indicates that the over temperature alarm temperature is130

The preset value is130

4

Press the 'Function' button

4-150

Indicating that the over temperature trip temperature is150

The preset value is150

5

Press the 'Function' button

H-000

Indicates that the scheduled start time of the fan is24(hour)

The preset value is024, (hour)

000Indicates the cancellation of this feature

6

Press the 'Function' button

P-001

Indicate the address of the thermostat,Used for communication

The preset value is001

7

Press the 'Function' button

Return temperature display working status

6 Modification of control parameters and simulation testing operations

step

key

display

speak bright

have pour

1

Press the 'Function' button

1-080

Turn off the fan temperature

The preset value is80

2

Press the "Manual Fan" button three times

1.-080

Turn off the fan temperature

The first decimal on the digital display lights up, press“+”Or“-”The key can be used to set the temperature for turning off the fan

3

Press the 'Function' button

2.-100

Turn on the fan temperature

Press now“+ Or“-”The key can be used to set the temperature for turning on the fan

4

Press the 'Function' button

3.-130

Overtemperature alarm temperature

Press now“+ Or“-”The key can set the alarm temperature

5

Press the 'Function' button

4.-150

Overtemperature tripping temperature

Press now“+ Or“-”The key can set the trip temperature

6

Press the 'Function' button

H.-024

Timing start time of fan

(hour)

Press now“+ Or“-”The key can be used to set the timed start time of the fan(hour)000Indicates the cancellation of this feature

7

Press the 'Function' button

P.-001

Temperature controller address,Used for communication

Press now“+ Or“-”Key to set communication address

8

Press the 'Function' button

==000

Simulate the working state of the temperature controller

Press now“+ Or“-”The key can add or subtract simulated temperature values, and pressing the "Manual Fan" key can add or subtract simulated temperature values10At the same time, the temperature controller produces corresponding control outputs. For example, when the simulated temperature reaches130At the same time, the temperature controller immediately triggers an audible and visual alarm, and the alarm terminal on the rear cover plate is closed

9

Press the 'Function' button

Return temperature display working status

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!