Three models equipped with 1, 2, and 4 card slots Build a multi-channel (up to 256 channels) network through LAN interface
characteristic
A multi-channel measuring instrument capable of measuring up to 256 channels. By selecting a wide variety of amplifier cards, it is possible to cope with a variety of measurements.
Product Overview
show all
EDX-100A-1 1 card slot, maximum analog input (channel) 8
specifications
Model name
EDX-100A-1 EDX-100A-1-0 EDX-100A-1-1
Number of input channels
8
analog input
EDX series amplifier card After installing DPM, CDV, CTA, CFV, CCA, CVM, use
CAN data input
Can install 1 CAN-41A
Voice memo input
1 channel By using a dedicated remote control RCU-64A (optional), it can be included in the catalog together Record the input voice memo and measurement data DAS-200A (optional) is required for playback of recorded voice memos
sampling frequency
Sampling method
All channels are synchronously sampled
Sampling frequency type
1-2-5 series: 1Hz~100kHz, 2nSeries: 2~65536Hz
sampling period
1Hz~100kHz (1-2-5 series): When recording up to 1 channel of data 1Hz~50kHz (1-2-5 series): When recording up to 3 channels of data 1Hz~20kHz (1-2-5 series): When recording up to 8 channels of data 1Hz~10kHz (1-2-5 series): When recording up to 16 channels of data 1Hz~5kHz (1-2-5 series): When recording up to 32 channels of data 1Hz~1kHz (1-2-5 series): When collecting CAN data
Data recording system
Compact Flash Card (CF Card) (128MB~8GB: 45x speed or above) However, the maximum measurement size for recording data once is 2GB
Condition setting method
Online settings: Set up on the computer via LAN or USB Offline settings: The setting conditions in the CF storage card are set by reading from this recorder (the measurement conditions are created using DCS-100A)
Condition saving
The amplifier setting conditions and measurement conditions are saved in the EDX's built-in non functional memory After turning on the power next time, data can be immediately recorded according to the previous conditions
Measurement mode
manual measurement
When starting and stopping data collection by user operation, or stopping data collection by the set number of data, a voice memo can be recorded at the same time for this measurement
Trigger measurement
It has the function of automatically recording through pre-set triggering conditions (Note) Cannot be triggered by CAN data
time interval measurement
Automatically collect data based on pre-set time interval measurement conditions
Collection start and stop
Implemented through computer, panel switch, and dedicated remote control
Balance adjustment operation (balance operation)
Balance adjustment of strain input channels through computer, panel switch, and dedicated remote control
Data format for inclusion
Republic Standard Format KS2 Format Through the selected data analysis software DAS-200A
Data recycling
Recycling online through a computer or directly reading recycling data by inserting a CF storage card into the computer
TEDS function
When only controlled online by a computer Corresponding amplifier card: CDV-40B(-F),DPM-42B-F,DPM-42B-I-F,CVM-41A,CCA-40A(-F),CDV-44AS,CDA-44AS,CDA-45AS,AD-40AS(-F)
Synchronous operation function
Up to 8 units can be directly connected through synchronous cables The collected data can be recorded separately as other files on the CF storage card inserted into the EDX The data of each EDX can be collected online and offline through a computer and integrated into one file
Analog Output
Through the analog output connectors of each amplifier card Monitored voltage (± 5VFS, except for CDV-40B (- F), AD-40AS, CAN-41A)
CF memory card I/F
1 card slot (for data collection and employment, used for setting conditions)
Communication I/F
Select through LAN and USB (for control and data transfer) toggle switches
The host weighs approximately 1.6kg (approximately 1.7kg when installing one CDV-40B)
Standard accessories
USB cable (N-38), DC power cord P-76 (1.8m), ground wire P-72 (5m) Dynamic data recording software DCS-100A (DVD), CF memory card
Optional parts
USB cable N-39 (2m) Synchronous cable N-128 (2m) Camera synchronization cable N-98, N-99, N-101 AC adapter UIA345-12 Cable fixing tool EDX uses synchronous extension unit ESYN-30A Remote control unit RCU-419 EDX-100A/200A instantaneous power outage battery unit EDB-41B Display Unit EMON-20A Cover plate EDX2000-DUMMY
EDX-100A-2 2 card slots, maximum analog input (channel) 16
EDX-100A-4 4 card slots, maximum analog input (channel) 32
specifications
Model name
EDX-100A-4 EDX-100A-4-0 EDX-100A-4-1
Number of input channels
32
analog input
EDX series amplifier card After installing DPM, CDV, CTA, CFV, CCA, CVM, use
CAN data input
Can install 1 CAN-41A
Voice memo input
1 channel By using a dedicated remote control RCU-64A (optional), it can be included in the catalog together Record the input voice memo and measurement data DAS-200A (optional) is required for playback of recorded voice memos
sampling frequency
Sampling method
All channels are synchronously sampled
Sampling frequency type
1-2-5 series: 1Hz~100kHz, 2nSeries: 2~65536Hz
sampling period
1Hz~100kHz (1-2-5 series): When recording up to 1 channel of data 1Hz~50kHz (1-2-5 series): When recording up to 3 channels of data 1Hz~20kHz (1-2-5 series): When recording up to 8 channels of data 1Hz~10kHz (1-2-5 series): When recording up to 16 channels of data 1Hz~5kHz (1-2-5 series): When recording up to 32 channels of data 1Hz~1kHz (1-2-5 series): When collecting CAN data
Data recording system
Compact Flash Card (CF Card) (128MB~8GB: 45x speed or above) However, the maximum measurement size for recording data once is 2GB
Condition setting method
Online settings: Set up on the computer via LAN or USB Offline settings: The setting conditions in the CF storage card are set by reading from this recorder (the measurement conditions are created using DCS-100A)
Condition saving
The amplifier setting conditions and measurement conditions are saved in the EDX's built-in non functional memory After turning on the power next time, data can be immediately recorded according to the previous conditions
Measurement mode
manual measurement
When starting and stopping data collection by user operation, or stopping data collection by the set number of data, a voice memo can be recorded at the same time for this measurement
Trigger measurement
It has the function of automatically recording through pre-set triggering conditions (Note) Cannot be triggered by CAN data
time interval measurement
Automatically collect data based on pre-set time interval measurement conditions
Collection start and stop
Implemented through computer, panel switch, and dedicated remote control
Balance adjustment operation (balance operation)
Balance adjustment of strain input channels through computer, panel switch, and dedicated remote control
Data format for inclusion
Republic Standard Format KS2 Format Through the selected data analysis software DAS-200A
Data recycling
Recycling online through a computer or directly reading recycling data by inserting a CF storage card into the computer
TEDS function
When only controlled online by a computer Corresponding amplifier card: CDV-40B(-F),DPM-42B-F,DPM-42B-I-F,CVM-41A,CCA-40A(-F),CDV-44AS,CDA-44AS,CDA-45AS,AD-40AS(-F)
Synchronous operation function
Up to 8 units can be directly connected through synchronous cables The collected data can be recorded separately as other files on the CF storage card inserted into the EDX The data of each EDX can be collected online and offline through a computer and integrated into one file
Analog Output
Through the analog output connectors of each amplifier card Monitored voltage (± 5VFS, except for CDV-40B (- F), AD-40AS, CAN-41A)
CF memory card I/F
1 card slot (for data collection and employment, used for setting conditions)
Communication I/F
Select through LAN and USB (for control and data transfer) toggle switches
The host weighs about 2.0kg (about 2.6kg when installing 4 CDV-40B)
Standard accessories
USB cable (N-38), DC power cord P-76 (1.8m), ground wire P-72 (5m) Dynamic data recording software DCS-100A (DVD), CF memory card
Optional parts
USB cable N-39 (2m) Synchronous cable N-128 (2m) Camera synchronization cable N-98, N-99, N-101 AC adapter UIA345-12 Cable fixing tool EDX uses synchronous extension unit ESYN-30A Remote control unit RCU-419 EDX-100A/200A instantaneous power outage battery unit EDB-41B Display Unit EMON-20A Cover plate EDX2000-DUMMY
EDX-100A-1H 1 card slot, maximum analog input (channel) 8
specifications
Model name
EDX-100A-1H EDX-100A-1H-0 EDX-100A-1H-1
Number of input channels
8
analog input
EDX series amplifier card After installing DPM, CDV, CTA, CFV, CCA, CVM, use
CAN data input
Can install 1 CAN-41A
Voice memo input
1 channel By using a dedicated remote control RCU-64A (optional), it can be included in the catalog together Record the input voice memo and measurement data DAS-200A (optional) is required for playback of recorded voice memos
sampling frequency
Sampling method
All channels are synchronously sampled
Sampling frequency type
1-2-5 series: 1Hz~100kHz, 2nSeries: 2~65536Hz
sampling period
1Hz~100kHz (1-2-5 series): When recording up to 1 channel of data 1Hz~50kHz (1-2-5 series): When recording up to 3 channels of data 1Hz~20kHz (1-2-5 series): When recording up to 8 channels of data 1Hz~10kHz (1-2-5 series): When recording up to 16 channels of data 1Hz~5kHz (1-2-5 series): When recording up to 32 channels of data 1Hz~1kHz (1-2-5 series): When collecting CAN data
Data recording system
Compact Flash Card (CF Card) (128MB~8GB: 45x speed or above) However, the maximum measurement size for recording data once is 2GB
Condition setting method
Online settings: Set up on the computer via LAN or USB Offline settings: The setting conditions in the CF storage card are set by reading from this recorder (the measurement conditions are created using DCS-100A)
Condition saving
The amplifier setting conditions and measurement conditions are saved in the EDX's built-in non functional memory After turning on the power next time, data can be immediately recorded according to the previous conditions
Measurement mode
manual measurement
When the user starts and stops recording data, or stops recording formal measurements based on the set number of data, a voice memo can be recorded
Trigger measurement
It has the function of automatically recording through pre-set triggering conditions (Note) Cannot be triggered by CAN data
time interval measurement
Automatically collect data based on pre-set time interval measurement conditions
Collection start and stop
Implemented through computer, panel switch, and dedicated remote control
Balance adjustment operation (balance operation)
Balance adjustment of strain input channels through computer, panel switch, and dedicated remote control
Data format for inclusion
Republic Standard Format KS2 Format Through the selected data analysis software DAS-200A
Data recycling
Recycling online through a computer or directly reading recycling data by inserting a CF storage card into the computer
TEDS function
When only controlled online by a computer Corresponding amplifier card: CDV-40B(-F),DPM-42B-F,DPM-42B-I-F,CVM-41A,CCA-40A(-F),CDV-44AS,CDA-44AS,CDA-45AS,AD-40AS(-F)
Synchronous operation function
Up to 8 units can be directly connected through synchronous cables The collected data can be recorded separately as other files on the CF storage card inserted into the EDX The data of each EDX can be collected online and offline through a computer and integrated into one file
Analog Output
Through the analog output connectors of each amplifier card Monitored voltage (± 5VFS, except for CDV-40B (- F), AD-40AS, CAN-41A)
CF memory card I/F
1 card slot (for data collection and employment, used for setting conditions)
Communication I/F
Select through LAN and USB (for control and data transfer) toggle switches
The host weighs approximately 1.6kg (approximately 1.7kg when installing one CDV-40B)
Standard accessories
USB cable (N-38), DC power cord P-76 (1.8m), ground wire P-72 (5m) Dynamic data recording software DCS-100A (DVD), CF memory card
Optional parts
USB cable N-39 (2m) Synchronous cable N-128 (2m) Camera synchronization cable N-98, N-99, N-101 AC adapter UIA345-12 Cable fixing tool EDX uses synchronous extension unit ESYN-30A Remote control unit RCU-419 EDX-100A/200A instantaneous power outage battery unit EDB-41B Display Unit EMON-20A Cover plate EDX2000-DUMMY