ET6030 Chlorine Dioxide (ClO2) Concentration Tester
ET6030 Data Type Chlorine Dioxide (CIO2) Concentration Tester
Product details

ET6030 Data Type Chlorine Dioxide (CIO2) Concentration Tester
Range: 0.02-11mg/L CIO2 measurement, infrared data transmission function, 16 sets of data storage, can be accessed at any time, GLP management function, dual modes of factory calibration and user-defined calibration, waterproof design, suitable for rapid sample analysis and measurement in laboratories and on-site
Standard configuration● Exquisite and portable, easy to operate, precise and fast measurement
● Background light display screen, GLP function, automatic shutdown setting
16 sets of data storage, which can be accessed and read at any time, making it convenient for on-site data organization and recording
Infrared transmission design, IRiM infrared transmitter (ET214050) and computer connection
● Factory and user-defined dual calibration function, automatically remembers the last zero calibration when the instrument is turned off, eliminating the need to calibrate the instrument zero every time it is measured, ensuring accurate and reliable measurement
Waterproof sample pool design, prefabricated supporting reagents, more reasonable operation and maintenance
● Applied to water treatment, wastewater/drinking water, cooling water/boiler water, swimming pool water, etc
The ET6030 chlorine dioxide analyzer adopts SMD microcomputer control technology, high-quality narrow band filter, temperature compensated LED optical system, compact overall design, waterproof sample pool, ensuring fast and accurate measurement with good reproducibility. It has calibration function and built-in software adjustment function, and is used for scientific research, measurement, sample testing, and identification.
The ET6030 chlorine dioxide analyzer adopts SMD microcomputer control technology, high-quality narrow band filter, temperature compensated LED optical system, compact overall design, waterproof sample pool, ensuring fast and accurate measurement with good reproducibility. It has calibration function and built-in software adjustment function, and is used for scientific research, measurement, sample testing, and identification.
Technical specifications for ET6030 chlorine dioxide (ClO2) concentration analyzer | ||
Host model | MD100 | |
range | 0.02-11mg/L ClO2 | |
accuracy | ±0.1mg/L(≤1.9mg/l),±0.2mg/L(≤3.8mg/l) ±0.4mg/L(≤5.7mg/l),±0.6mg/L(≤7.6mg/l) ±0.8mg/L(≤11mg/l) |
|
resolution | 0.01mg/L | |
Reagent type | ET511050 Chlorine Dioxide Reagent (Tablets 100) | |
optical system | 530nm, waterproof sample cell, equipped with temperature compensated LED optical system, wavelength accuracy ± 1nm | |
Photometric index | Resolution: 0.01A, Accuracy: 3% F.S | |
Calibration Mode | Automatic zero point calibration, using SMD microprocessing technology, with factory calibration and user-defined calibration modes | |
data management | 16 sets of measurement data are automatically stored using the IRiM infrared data transmission module | |
Power supply mode | 4X1.5AAA battery with automatic shutdown and power-saving function (10 minutes) | |
Usage environment | 5-40°C; RH: 30-90% non condensing | |
Dimension | 155×75×35mm/260g |
MD100 host, standard ET511050 chlorine dioxide reagent (tablets, 100), ET197620 (Ø 24mm) dedicated glass colorimetric dish (2 pieces), ET197635 colorimetric dish cleaning cloth (2 pieces), Chinese and English user manual, instrument specific carrying case
Note: If the water sample with high concentration of calcium or high conductivity appears turbid, replace the ET511050 reagent with the ET515740 reagent; Chlorine containing water samples can be treated with ET512170 reagent to remove chlorine interference and ensure data accuracy.