Shanghai Xuansheng Scientific Instrument Co., Ltd
Home>Products>Economic natural gas analyzer instrument Gas chromatograph
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15021595718,15121127657
  • Address
    Jiading Industrial Park, Shanghai
Contact Now
Economic natural gas analyzer instrument Gas chromatograph
Economic natural gas analyzer instrument Gas chromatograph
Product details

Economic natural gas analyzer instrument Gas chromatograph

Model comparison:

Instrument model

applications

Testing components

detection result

GC-8850

LNG

Nitrogen, methane, ethane, propane

Component content, high calorific value, low calorific value, density, relative density, and white matter number.

GC-9850

LNG、CNG、 pipeline gas

Nitrogen, methane, ethane, propane, n-butane, isobutane

Natural gas analysis is mainly used for natural gas production manufacturers and liquid plant testing equipment. Based on third-party testing standards, Shanghai Xuansheng Natural Gas Analyzer adheres to unified testing execution standards for accurate analysis results. With the self injection method, errors caused by manual injection are eliminated to achieve precise and accurate reproducibility of analysis results

Economic natural gas analyzer instrument Gas chromatographProduct Description:

GC-The 8850 fully automatic gas analyzer is a high-performance instrument produced by Shanghai Xuansheng Scientific Instrument Co., Ltd. It is mainly used for detecting liquid nitrogen in LNG, detecting methane, ethane, and propane content, analyzing natural gas calorific value and density, and calculating gasification rate based on density.

The instrument has a stylish appearance and beautiful design; 8-inch display screen, displaying rich and intuitive content; Small in size, light in weight, and easy to carry, it is suitable for laboratory testing and analysis of LNG users, as well as for gas companies to carry instruments to multiple user points for testing.

The operation of this instrument is very simple, even personnel who have not been in contact with this instrument can learn it at once. Insert the gas sampling bag into the 'sample inlet' of the instrument, and press the 'start' button to automatically run the instrument (automatic sampling, automatic analysis, automatic signal collection, no need for manual intervention). Automatically calculate the detection results within 10 minutes.

This machine integrates an analysis column, detector, working software, and computer. Convenient to carry, suitable for both online pipeline inspection in industrial sites and airbag sampling analysis in laboratories;

● Integrated sealed heating, with low heat dissipation ratio, higher efficiency, and energy savings;

● Dual channel calorific value working software, automatically calculates the detected gas component content, high calorific value, low calorific value, density, relative density, Huabai number, combustion potential, etc;

Built in automatic sampling pump and electric injection valve to improve the repeatability of detection results;

Can be equipped with a mouse and printer;

Reference standards:
GB/T 10410-2008 "Gas Chromatography Analysis Method for Constant Components of Artificial Gas and Liquefied Petroleum Gas"
GB/T 12208-2008 "Determination of Composition and Impurity Content of Artificial Gas"
GB/T 11062-1998 "Calculation Method for Heating Value, Density, Average Density, and Wopo Index of Natural Gas"
SH/T 0230-92 "Determination of Composition of Liquefied Petroleum Gas (Chromatography Method)"
GB/T 13610-2003 "Composition Analysis of Natural Gas - Gas Chromatography Method"
GB/T 12206-2006 "Determination of Heating Value and Relative Density of Urban Gas"
GB 10410.1-89 "Gas Chromatography Analysis Method for Components of Artificial Gas"
GB 10410.2-89 "Gas chromatographic analysis of constant components in natural gas"
GB 10410.3-89 "Gas Chromatography Analysis of Liquefied Petroleum Gas Components"

Product advantages

Convenient to carry

Portable gas analyzer Portable automatic gas analyzer

This instrument adopts a modular design, with one click start, making operation easier and reducing costs

Technical requirements for personnel include automatic sample extraction, automatic sample injection, and automatic data collection,

Automatically calculate results.Carrier gas: high-purity hydrogen gas (purity ≥ 99.995%)

Built in calorific value software automatically calculates component content, high calorific value, low calorific value, density, relative density, Hua Bai number, and combustion potential

TCD sensitivity S ≥ 3000mv. ml/mg (benzene) noise ≤ 0.02mv

Air intake requirements: dust-free, waterless, oil-free

Built in injection valve: automatic injection, automatic reset (module control)

Qualitative time error: ≤ 0.02min

Detection *. 1%



Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!