Technical parameters:
→ General Technical Specifications
→ Electrical signal measurement
→ Pressure measurement
→ Generation, measurement/simulation of electrical signals
→ Standard configuration attachments
→ Options Attachment
General technical parameters (applicable to all models):
features
explain
display
60 mm×60mm; 160 × 160 pixels, LCD display with backlight
weight
770g
size
215mm×102mm×49mm(D/W/H)
keyboard
Thin film keyboard
Battery type
Rechargeable NiMH, 4000mAh, 3.6V DC
Charging time
5 hours
Charging power supply
100~240VAC,50~60Hz
Battery settings
13-24-hour measurement mode, background light off;
The 8-12 hour mode provides a 12mA circuit power supply with the background light on.
Optional 4 alkaline battery settings
8-hour measurement mode, background light off;
4-hour measurement mode provides 12mA circuit power supply, with background light on
working temperature
-10~50℃(14~122℉)
Working temperature during charging
0~35℃(32~95℉)
Storage temperature
-20~60℃(-4~140℉)
humidity
0 to 80% non condensing
Preheating time
Effective after 5 minutes of preheating
Maximum input voltage
30V DC,60V DC
safety standards
Derective 73/23/EEC,EN61010-1
EMC
Derective 89/336/EEC,EN61010-1

Voltage measurement(-160V DC)

range
resolving power
1-year uncertainty
±0.25V
0.001mV
0.02%RDG+5µV
±(0.25~1V)
0.01mV
0.02%RDG+5µV
1~25V
0.1mV
0.02%RDG+0.25mV
25~60V
1mV
0.02%RDG+0.25mV
characteristic
parameter
temperature coefficient
<±0.0015%RDG/℃ outside of 18~28℃
<±0.0008RDG/℉ outside of 64.4~82.4℉
Input impedance
>1Mohm
selectable unit
V, mV, µV
Display refresh rate
3/second

characteristic
parameter
temperature coefficient
<±0.0015%RDG/℃ outside of 18~28℃
<±0.0008RDG/℉ outside of 64.4~82.4℉
Input impedance
<7.5ohm
selectable unit
mA, µA
Display refresh rate
3/second

Circuit power supply

characteristic
parameter
Output current
Maximum 25mA, short circuit protection
output voltage
24V±10%
Output impedance in HART compatible mode
300ohm±20%
range
resolving power
1-year uncertainty
±25mA
0.0001mA
0.02%RDG+1.5µA
±(25~100mA)
0.001mA
0.02%RDG+1.5µA


Electrical signal measurement

frequency measurement(0.002750,000Hz)
range
resolving power
1-year uncertainty
0.0027~0.5Hz
0.000001 Hz
0.01%RDG
0.5~5 Hz
0.00001 Hz
0.01%RDG
5~50 Hz
0.0001 Hz
0.01%RDG
50~500 Hz
0.001 Hz
0.01%RDG
500~5000 Hz
0.01 Hz
0.01%RDG
5000~50000 Hz
0.1 Hz
0.01%RDG
characteristic
parameter
temperature coefficient
Specification valid from 10 to 50℃
Input impedance
>1 Mohm
Trigger level
-1~14v in 1v steps and open collector inputs
Minimum signal amplitude
2Vpp(<10kHz),3Vpp(10~50kHz)
selectable unit
Hz,kHz,cph,cpm,1/Hz(s),1/kHz(ms),1/MHz(us)
Switching time
267ms+1signal period


Pulse counting

characteristic
parameter
range
0 ~ 9999999 pulse
Input impedance
>1Mohm
Trigger level
-1~14V in 1V steps and open collector inputs
Minimum signal amplitude
2Vpp(pulse length>50us),3Vpp(pulse length 10..50us)

Switch quantity test

characteristic
parameter
Potential zero point
Test voltage (current)
2.8V (0.13A) or 24V (35A)
Level detection
Input impedance
>1 Mohm
Trigger level
-1~14V in 1V steps

pressure measurement
Internal pressure module(IPM)

Internal module
Company
range
resolving power
1Annual uncertainty
IPM200mC
kPa
mbar
iwc
±20
±200
±80
0.001
0.01
0.01
0.05% RDG + 0.05% FS
IPM2C
kPa
bar
psi
-100 ~ 200
-1 ~ 2
-14.5 ~ 30
0.01
0.0001
0.001
0.05% FS
IPM20C
kPa
bar
psi
-100 ~ 2000
-1 ~ 20
-14.5 ~ 300
0.1
0.001
0.01
0.05% FS
IPM160
MPa
bar
psi
0 ~ 16
0 ~ 160
0 ~ 2400
0.001
0.01
0.1
0.05% FS
Atmospheric pressure module options
If an atmospheric pressure module (with an uncertainty of 0.1 kPa) is selected, the above pressure can be measured in absolute pressure.
characteristic
parameter
temperature coefficient
<±0.001%RDG/℃ outside 15~35℃
<±0.0006%RDG/℉ outside 59~95℉
Maximum overvoltage protection
2 times the range
Pressure interface
G 1/8 "internal thread (ISO 228/1) 60 ° internal cone
Media compatibility
Wet parts: AISI316 stainless steel, nitrile rubber
Pressure unit
Pa、hPa、kP、MPa、mbar、lbf/ft2、kgf/cm2、 kgf/m2、 kgf/m2、 at、mmH2O、cmH2O、mH2O、iwc、ftH2O. MmHg, cmHg, mHg, minHg, mmHg (0 ℃), inHg (0 ℃) mmH2O (4 ℃), inH2O (4 ℃) ftH2O (4 ℃) inH2O (60 ℉) mmH2O (68 ℉) ftH2O (68 ℉) tm、 4 users set units
Display refresh rate
2.5 per second

High precision external pressure module(EXT)
External module
amount Cheng
1Annual uncertainty
atmospheric pressure
800~1200 mbar absolute pressure
80~120 kPa absolute pressure, enabling the instrument to have absolute pressure measurement function
0.05 kpa (0.015 inHg)
EXT10mD
± 10 mbar micro differential pressure
± 1 kPa micro differential pressure
0.1% RDG + 0.05% Span
EXT100m
0~100 mbar gauge pressure
0~10kpa gauge pressure
0.04% RDG + 0.025% FS
EXT400mC
±400 mbar
-40kpa ~ 40kpa
0.04% RDG + 0.02% FS
EXT1C
±1 bar
-100kpa ~ 100kpa
0.04% RDG + 0.01% FS
EXT2C
-1 ~ 2 bar
-100kpa ~ 200kpa
0.04% RDG + 0.01% FS
EXT6C
-1 ~ 6 bar
-100kpa ~ 600kpa
0.04% RDG + 0.01% FS
EXT20C
-1 ~ 20 bar
-0.1 ~ 2MPa
0.04% RDG + 0.01% FS
EXT60
0 ~ 60 bar
0 ~ 6MPa
0.04% RDG + 0.01% FS
EXT100
0 ~ 100 bar
0 ~ 10MPa
0.04% RDG + 0.01% FS
EXT160
0 ~ 160 bar
0 ~ 16MPa
0.04% RDG + 0.013% FS
EXT250
0 ~ 250 bar
0 ~ 25MPa
0.04% RDG + 0.015% FS
EXT600
0 ~ 600 bar
0 ~ 60MPa
0.04% RDG + 0.015% FS
EXT1000
0 ~ 1000 bar
0 ~ 100MPa
0.04% RDG + 0.015% FS
Standard precision external pressure module(EXT)
External module
amount Cheng
resolving power
1Annual uncertainty
EXT200mC-s
±200 mbar
-20kpa ~ 20kpa
0.01 mbar
0.05% RDG + 0.05% FS
EXT2C-s
-1 ~ 2 bar
-100kpa ~ 200kpa
0.0001 bar
0.05% FS
EXT20C-s
-1 ~ 20 bar
-0.1 ~ 2MPa
0.001 bar
0.05% FS
EXT160-s
0 ~ 160 bar
0 ~ 16MPa
0.01 bar
0.05% FS
                                             

Standard configuration:
User Guide
Verification certificate
, , NiMH rechargeable batteries and chargers
A pair of test wires and clamps
USB cable
Pressure connection adapter G1/8 "internal thread - G 1/8" external thread with 60 ° internal cone (PE, MF models also available)

Optional accessories:
Pressure hose tee
Carrying a soft bag
Connection cable for external pressure module
Dry battery cylinder
PG series calibration hand pump
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!